Skip to main content
CVE Vulnerability Database
Vulnerability Database/CVE-2025-46783

CVE-2025-46783: RICOH Streamline NX Path Traversal Flaw

CVE-2025-46783 is a path traversal vulnerability in RICOH Streamline NX V3 PC Client that enables attackers to execute arbitrary code by tampering with specific files. This article covers technical details, affected versions, and mitigation.

Published:

CVE-2025-46783 Overview

A critical path traversal vulnerability has been identified in RICOH Streamline NX V3 PC Client that allows attackers to execute arbitrary code on affected systems. The vulnerability exists in versions 3.5.0 through 3.242.0 of the software and can be exploited by tampering with specific files used by the product. This security flaw (CWE-22) enables malicious actors to bypass directory restrictions and manipulate files outside the intended directory structure, ultimately leading to arbitrary code execution on the target PC.

Critical Impact

This network-accessible vulnerability allows unauthenticated attackers to achieve arbitrary code execution by exploiting path traversal to tamper with critical application files, potentially leading to complete system compromise.

Affected Products

  • RICOH Streamline NX V3 PC Client version 3.5.0
  • RICOH Streamline NX V3 PC Client versions through 3.242.0
  • All intermediate versions between 3.5.0 and 3.242.0

Discovery Timeline

  • 2025-06-13 - CVE-2025-46783 published to NVD
  • 2025-06-16 - Last updated in NVD database

Technical Details for CVE-2025-46783

Vulnerability Analysis

This path traversal vulnerability (CWE-22) in RICOH Streamline NX V3 PC Client stems from improper validation of file paths within the application. The vulnerability is accessible over the network without requiring authentication or user interaction, making it particularly dangerous in enterprise environments where Streamline NX is deployed for document workflow management.

When exploited, attackers can traverse outside the intended directory structure to access, modify, or replace critical system files. The ultimate impact is arbitrary code execution on the PC running the affected software, giving attackers the ability to execute malicious payloads with the privileges of the application process.

Root Cause

The root cause of CVE-2025-46783 is insufficient input validation and path sanitization when handling file paths within the RICOH Streamline NX V3 PC Client. The application fails to properly validate or canonicalize user-supplied file path inputs, allowing directory traversal sequences (such as ../) to escape the intended directory boundaries. This enables attackers to reference and manipulate files in arbitrary locations on the file system, including executable files or configuration data that can lead to code execution.

Attack Vector

The attack vector for this vulnerability is network-based, requiring no authentication or user interaction. An attacker can remotely exploit this vulnerability by crafting malicious requests containing path traversal sequences targeting specific files used by the RICOH Streamline NX V3 PC Client.

The exploitation flow typically involves:

  1. Identifying accessible network endpoints of the vulnerable PC Client
  2. Crafting path traversal payloads using sequences like ../ or encoded variants
  3. Targeting specific application files that, when tampered with, result in code execution
  4. Delivering malicious content to replace or modify legitimate files
  5. Triggering execution of the tampered files to achieve arbitrary code execution

For detailed technical information regarding exploitation mechanics, refer to the JVN Security Advisory and Ricoh Security Vulnerability Report.

Detection Methods for CVE-2025-46783

Indicators of Compromise

  • Unusual file access patterns targeting directories outside the Streamline NX installation path
  • Presence of unexpected files or modifications to legitimate application files in the Streamline NX installation directory
  • Network traffic containing path traversal sequences (../, ..%2f, %2e%2e/) directed at systems running the PC Client
  • Anomalous process execution originating from the Streamline NX application directory

Detection Strategies

  • Implement file integrity monitoring (FIM) on critical Streamline NX application files and directories
  • Deploy network intrusion detection rules to identify path traversal patterns in traffic to systems running the PC Client
  • Configure endpoint detection solutions to alert on suspicious file modifications within the Streamline NX installation path
  • Monitor for unusual outbound connections from Streamline NX processes indicating potential post-exploitation activity

Monitoring Recommendations

  • Enable verbose logging on systems running RICOH Streamline NX V3 PC Client to capture file access events
  • Implement SIEM correlation rules to detect path traversal indicators across network and endpoint telemetry
  • Conduct regular integrity checks on Streamline NX installation directories
  • Monitor for process creation events with suspicious parent-child relationships involving Streamline NX components

How to Mitigate CVE-2025-46783

Immediate Actions Required

  • Verify all installations of RICOH Streamline NX V3 PC Client and identify systems running vulnerable versions (3.5.0 through 3.242.0)
  • Review the official security advisory from Ricoh for patch availability and apply updates immediately
  • Implement network segmentation to limit exposure of vulnerable systems while patching is in progress
  • Enable enhanced monitoring on systems running the affected software to detect exploitation attempts

Patch Information

Organizations should consult the official Ricoh Security Vulnerability Report for detailed patch information and the latest secure version of RICOH Streamline NX V3 PC Client. The JVN Security Advisory provides additional guidance on remediation steps. It is critical to update all affected installations to a patched version as soon as one becomes available from the vendor.

Workarounds

  • Restrict network access to systems running RICOH Streamline NX V3 PC Client using firewall rules to limit exposure to trusted networks only
  • Implement application whitelisting to prevent execution of unauthorized code even if files are tampered with
  • Deploy web application firewall (WAF) rules to filter requests containing path traversal sequences if applicable to the deployment architecture
  • Consider temporarily disabling the affected software in high-risk environments until a patch can be applied
bash
# Example: Restrict network access to Streamline NX PC Client systems
# Windows Firewall rule to limit inbound connections to trusted subnet
netsh advfirewall firewall add rule name="Restrict Streamline NX Access" dir=in action=allow protocol=tcp localport=<PORT> remoteip=10.0.0.0/8
netsh advfirewall firewall add rule name="Block Streamline NX External" dir=in action=block protocol=tcp localport=<PORT>

Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.

Default Legacy - Prefooter | Experience the World’s Most Advanced Cybersecurity Platform

Experience the Most Advanced Cybersecurity Platform

See how the world’s most intelligent, autonomous cybersecurity platform can protect your organization today and into the future.