Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.
Sources: National Vulnerability Database, CISA KEV, Exploit-DB
CVE-2024-57578 Overview
CVE-2024-57578 is a stack overflow vulnerability affecting the Tenda AC18 router running firmware version 15.03.05.19. The flaw resides in the formSetCfm function, where the funcpara1 parameter is processed without proper bounds checking. An attacker on an adjacent network can send a crafted request to trigger the overflow. Successful exploitation can corrupt the stack and lead to arbitrary code execution on the device. The vulnerability maps to [CWE-787] Out-of-Bounds Write and [CWE-120] Classic Buffer Overflow.
Critical Impact
Adjacent network attackers can trigger a stack overflow in formSetCfm and gain full control of the router, compromising confidentiality, integrity, and availability.
Affected Products
- Tenda AC18 router hardware
- Tenda AC18 firmware version 15.03.05.19
- Deployments exposing the web management interface on reachable network segments
Discovery Timeline
- 2025-01-16 - CVE-2024-57578 published to the National Vulnerability Database (NVD)
- 2026-06-17 - Last updated in NVD database
Technical Details for CVE-2024-57578
Vulnerability Analysis
The Tenda AC18 web management binary exposes the formSetCfm handler through its HTTP server. The handler consumes a user-controlled funcpara1 parameter and copies the value into a fixed-size stack buffer. Because the function does not validate the length of the incoming parameter, oversized input overwrites adjacent stack memory, including the saved return address.
An attacker who reaches the router from the same wireless or wired segment can send a single malformed HTTP request to reach the vulnerable code path. The attack requires no authentication and no user interaction. Overwriting the return address allows control of program flow, and exploitation typically pivots to shellcode or ROP gadgets within the firmware image.
Technical details and reproduction notes are documented in the GitHub PoC Repository. The flaw aligns with the broader pattern of unchecked strcpy or sprintf calls found across Tenda SOHO router form handlers.
Root Cause
The root cause is missing length validation on the funcpara1 HTTP parameter before it is copied into a fixed-size stack buffer inside formSetCfm. The function trusts attacker-supplied data and performs an unbounded copy, producing an out-of-bounds write on the stack.
Attack Vector
Exploitation requires network adjacency, meaning the attacker must reach the router's management interface over LAN or Wi-Fi. The attacker issues an HTTP request with an oversized funcpara1 value targeting the formSetCfm endpoint. No credentials or user interaction are required to trigger the overflow.
No verified exploit code is reproduced here. Refer to the vendor-independent proof-of-concept linked in the external references for payload structure.
Detection Methods for CVE-2024-57578
Indicators of Compromise
- HTTP POST requests to Tenda AC18 management endpoints containing abnormally long funcpara1 values
- Unexpected reboots or crashes of the httpd process on the router
- New or unknown outbound connections initiated by the router to attacker-controlled hosts
- Configuration changes to DNS, firewall, or administrative credentials that were not performed by an operator
Detection Strategies
- Inspect network traffic for HTTP requests to formSetCfm with funcpara1 parameters exceeding typical lengths (for example, over 256 bytes)
- Deploy IDS or IPS rules that match on the formSetCfm URI combined with oversized form parameters
- Correlate router-side crash logs with inbound HTTP traffic from internal hosts to identify exploitation attempts
Monitoring Recommendations
- Enable syslog forwarding from the router to a central collector and watch for httpd restarts
- Monitor LAN segments for lateral HTTP scanning targeting embedded management interfaces
- Track DHCP leases and device inventory for unauthorized clients on segments that can reach the router
How to Mitigate CVE-2024-57578
Immediate Actions Required
- Restrict management interface access to a dedicated administrative VLAN or wired segment
- Disable remote and wireless administration until a vendor patch is applied
- Rotate administrative credentials and verify current router configuration for unauthorized changes
- Replace end-of-life Tenda AC18 units if the vendor does not publish updated firmware
Patch Information
No vendor advisory or patched firmware release is referenced in the available CVE data at the time of publication. Monitor Tenda's official support channels for firmware updates addressing formSetCfm and apply them as soon as they are available.
Workarounds
- Place the router behind an upstream firewall that blocks untrusted hosts from reaching the HTTP management port
- Segment Wi-Fi guest networks from the management SSID to prevent adjacent-network exploitation
- Disable UPnP and any services that expose the HTTP management interface to broader networks
- Consider migrating to a supported router platform where embedded web stacks receive active maintenance
# Configuration example: restrict management access on an upstream firewall
# Allow only the admin workstation to reach the router web UI
iptables -A FORWARD -s 192.0.2.10/32 -d 192.168.0.1 -p tcp --dport 80 -j ACCEPT
iptables -A FORWARD -d 192.168.0.1 -p tcp --dport 80 -j DROP
iptables -A FORWARD -d 192.168.0.1 -p tcp --dport 443 -j DROP
Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.
Sources: National Vulnerability Database, CISA KEV, Exploit-DB

