Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.
Sources: National Vulnerability Database, CISA KEV, Exploit-DB
CVE-2026-87680 Overview
CVE-2026-87680 is a command injection vulnerability [CWE-78] in the Representational State Transfer (REST) Application Programming Interface (API) management interface of Broadcom Brocade Fabric Operating System (FOS). The flaw affects FOS versions before 10.0.1. An authenticated user on an adjacent network can execute arbitrary system commands by submitting crafted input parameters to the management API.
Critical Impact
Authenticated attackers with low privileges can execute arbitrary operating system commands on Brocade Fabric OS switches, compromising storage fabric confidentiality and integrity.
Affected Products
- Broadcom Brocade Fabric Operating System versions prior to 10.0.1
- Brocade SAN switches running vulnerable FOS firmware
- Fabric management infrastructure exposed to the REST API
Discovery Timeline
- 2026-10-08 - CVE-2026-87680 published to the National Vulnerability Database (NVD)
- 2026-10-13 - Last updated in NVD database
Technical Details for CVE-2026-87680
Vulnerability Analysis
The vulnerability resides in the REST API management interface of Brocade Fabric OS. The interface accepts parameters from authenticated callers and passes them to underlying system command execution without sufficient sanitization. An attacker with valid credentials can inject shell metacharacters into these parameters to break out of the intended command context.
Successful exploitation grants command execution with the privileges of the API service account. On storage fabric switches, this access can expose zoning configurations, credentials, and fabric routing data. The CVSS vector indicates adjacent network reach with low privileges and no user interaction required.
Root Cause
The root cause is improper neutralization of special elements used in an OS command [CWE-78]. The REST API handler constructs system command strings by concatenating user-supplied input with privileged shell operations. Shell metacharacters such as ;, |, &, and backticks are not escaped before invocation.
Attack Vector
Exploitation requires network reachability to the switch management plane and a valid authenticated session. The attacker sends a crafted HTTP request to a vulnerable REST endpoint with injected command payloads inside parameter values. The injected commands execute in the context of the backend management process.
The Exploit Prediction Scoring System (EPSS) places this issue in the 79.481 percentile, indicating elevated near-term exploitation probability relative to the broader CVE population. No public proof-of-concept exploit has been published at this time.
No verified public exploit code is available. Refer to the Broadcom Security Advisory
referenced below for authoritative vulnerability details.
Stop Remote Code Execution Before It Runs
Singularity™ Endpoint detects and blocks exploit attempts at machine speed, including zero-days and novel attack techniques.
Stop Exploit AttemptsDetection Methods for CVE-2026-87680
Indicators of Compromise
- Unexpected REST API requests containing shell metacharacters (;, |, &, $(), backticks) in parameter values
- Unusual outbound connections originating from Brocade FOS management interfaces
- New or modified administrative accounts, zoning configurations, or startup scripts on the switch
- Authentication events from low-privileged accounts followed by configuration changes outside normal change windows
Detection Strategies
- Enable REST API audit logging on Brocade FOS and forward events to a centralized Security Information and Event Management (SIEM) platform
- Baseline normal REST API usage patterns and alert on parameter payloads containing OS command separators
- Correlate authentication events against the switch management plane with subsequent process or configuration changes
Monitoring Recommendations
- Monitor all HTTP/HTTPS traffic to switch management IP addresses on a dedicated out-of-band management VLAN
- Alert on repeated authentication from service or read-only accounts to administrative API endpoints
- Track firmware version inventory to identify unpatched FOS instances still exposed to the management network
How to Mitigate CVE-2026-87680
Immediate Actions Required
- Upgrade Brocade Fabric OS to version 10.0.1 or later on all affected switches
- Rotate credentials for any accounts with REST API access on potentially exposed switches
- Restrict REST API access to a dedicated management network and trusted administrator hosts only
- Review audit logs for anomalous API activity dating back to the earliest reasonable exposure window
Patch Information
Broadcom addresses the vulnerability in Brocade Fabric OS 10.0.1 and later. Refer to the Broadcom Security Advisory #39074 for official remediation guidance and upgrade packages.
Workarounds
- Disable the REST API management interface on switches where it is not operationally required
- Enforce network access control lists restricting management plane access to authorized jump hosts
- Limit API user accounts to the minimum necessary role and remove unused service accounts
# Example: restrict REST API access on Brocade FOS to a management subnet
# Review current IP ACL configuration
ipfilter --show
# Create and activate a policy allowing only trusted admin hosts to reach HTTPS/REST
ipfilter --create mgmt_only -type ipv4
ipfilter --addrule mgmt_only -rule 1 -sip 10.10.0.0/24 -dp 443 -proto tcp -act permit
ipfilter --activate mgmt_only
Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.
Sources: National Vulnerability Database, CISA KEV, Exploit-DB