Skip to main content
Vulnerability Database/CVE-2026-94586

CVE-2026-94586: Broadcom Fabric OS RCE Vulnerability

CVE-2026-94586 is a command injection vulnerability in Broadcom Fabric Operating System that allows authenticated users to execute arbitrary commands with root privileges. This article covers technical details, affected versions, security impact, and mitigation strategies.

Published:

Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.

Sources: National Vulnerability Database, CISA KEV, Exploit-DB

CVE-2026-94586 Overview

CVE-2026-94586 is a command injection vulnerability [CWE-78] in the WebTools administrative interface of Broadcom Brocade Fabric OS. The flaw affects versions before 9.2.2d and versions 10.0.0 through 10.0.0a1. The vulnerable code paths handle configuration download and file transfer operations that accept remote server profile parameters. An authenticated user with sufficient permissions can inject shell metacharacters into these parameters. The injected commands execute on the switch with root privileges, giving the attacker full control of the storage area network (SAN) switch.

Critical Impact

Authenticated attackers on an adjacent network can execute arbitrary shell commands as root on Brocade Fabric OS switches, compromising SAN fabric integrity, confidentiality, and availability.

Affected Products

  • Broadcom Brocade Fabric OS versions before 9.2.2d
  • Broadcom Brocade Fabric OS version 10.0.0
  • Broadcom Brocade Fabric OS version 10.0.0a1

Discovery Timeline

  • 2026-10-08 - CVE CVE-2026-94586 published to NVD
  • 2026-10-14 - Last updated in NVD database

Technical Details for CVE-2026-94586

Vulnerability Analysis

The vulnerability resides in the WebTools administrative interface, which exposes configuration management operations to authorized operators. When a user initiates a configuration download or file transfer using a remote server profile, the backend passes profile parameters into shell commands without adequate sanitization. An attacker who controls these parameter strings can append shell metacharacters to break out of the intended command context. The resulting commands run under the Fabric OS root account, bypassing any role-based limits enforced at the application layer. Because Fabric OS switches orchestrate storage traffic, compromise of a single switch can cascade into fabric-wide impact. The adjacent network attack vector means the attacker must reach the management network, which is typically a segmented operations LAN.

Root Cause

The root cause is improper neutralization of special elements used in an operating system command [CWE-78]. User-supplied values from remote server profile fields are concatenated into shell invocations without quoting, escaping, or allow-list validation. This classic OS command injection pattern enables arbitrary command execution.

Attack Vector

Exploitation requires an authenticated account with permission to perform configuration downloads using remote server profiles. The attacker crafts a server profile or configuration transfer request containing shell metacharacters such as semicolons, backticks, or command substitution sequences in the parameter fields. When WebTools processes the request, the injected payload executes alongside the intended file-transfer command. No user interaction is required beyond the authenticated session, and the attacker gains root-level code execution on the switch management plane.

No public proof-of-concept exploit is currently available. Technical details are described in the Broadcom Security Advisory #39135.

Stop Remote Code Execution Before It Runs

Singularity™ Endpoint detects and blocks exploit attempts at machine speed, including zero-days and novel attack techniques.

Stop Exploit Attempts

Detection Methods for CVE-2026-94586

Indicators of Compromise

  • Unexpected shell processes spawned by WebTools or configuration-transfer daemons on Fabric OS switches.
  • Audit log entries showing configuration download or server profile operations containing shell metacharacters such as ;, |, &, `, or $(.
  • Unusual outbound connections from the switch management interface to unknown remote servers.
  • Modifications to switch configuration files, user accounts, or SSH keys outside of change-management windows.

Detection Strategies

  • Review Fabric OS audit logs (auditcfg, errshow) for anomalous WebTools activity tied to configuration downloads or remote server profiles.
  • Correlate authenticated WebTools sessions with process-execution telemetry from the switch management plane.
  • Alert on configuration-transfer requests where server profile fields contain non-alphanumeric payloads inconsistent with legitimate hostnames or paths.

Monitoring Recommendations

  • Centralize Fabric OS syslog output to a SIEM and build detections for WebTools command-execution anomalies.
  • Monitor management-network traffic for unauthorized access attempts to WebTools endpoints on affected switches.
  • Track administrative account usage and flag privileged configuration operations outside approved maintenance windows.

How to Mitigate CVE-2026-94586

Immediate Actions Required

  • Upgrade Brocade Fabric OS to version 9.2.2d or later, per the Broadcom Security Advisory #39135.
  • Restrict WebTools management access to a dedicated out-of-band management network and trusted administrator workstations only.
  • Audit all accounts with permission to perform configuration downloads and remove unnecessary privileges.
  • Rotate credentials for any Fabric OS account that may have been exposed on the management network.

Patch Information

Broadcom addresses the vulnerability in Fabric OS 9.2.2d. Customers running the 10.0.0 branch should consult Broadcom for a fixed release path, as versions 10.0.0 through 10.0.0a1 are affected. Refer to the Broadcom Security Advisory #39135 for complete upgrade guidance.

Workarounds

  • Enforce strict network segmentation so only authorized management hosts can reach the switch WebTools interface.
  • Disable WebTools where operational workflows do not require it, and use the command-line interface over SSH instead.
  • Apply role-based access controls to limit the number of users permitted to run configuration download operations with remote server profiles.
bash
# Configuration example: verify Fabric OS version and restrict management access
version
ipfilter --show
ipfilter --create mgmt_only -type ipv4
ipfilter --addrule mgmt_only -rule 1 -sip <trusted_mgmt_subnet> -dp 443 -proto tcp -act permit
ipfilter --activate mgmt_only

Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.

Sources: National Vulnerability Database, CISA KEV, Exploit-DB

Experience the Most Advanced Cybersecurity Platform

See how the world’s most intelligent, autonomous cybersecurity platform can protect your organization today and into the future.