Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.
Sources: National Vulnerability Database, CISA KEV, Exploit-DB
CVE-2026-5769 Overview
CVE-2026-5769 affects Broadcom Brocade SANnav versions before 3.0.1. The vulnerability allows the Brocade Fabric OS switch admin password to be captured in plaintext within a memory swap file on the server hosting the SANnav Virtual Machine. This exposure occurs when the SANnav server encounters an Out Of Memory (OOM) condition, forcing memory pages containing credentials to disk. An authenticated administrator with access to the underlying host can read the swap file and recover switch admin credentials. The weakness is categorized under CWE-313: Cleartext Storage in a File or on Disk.
Critical Impact
Exposure of Fabric OS switch admin passwords in plaintext enables lateral movement across managed storage area network (SAN) fabrics.
Affected Products
- Broadcom Brocade SANnav versions prior to 3.0.1
- Server hosts running the SANnav Virtual Machine
- Managed Brocade Fabric OS switches whose admin credentials are stored in SANnav
Discovery Timeline
- 2026-10-08 - CVE-2026-5769 published to the National Vulnerability Database (NVD)
- 2026-10-14 - Last updated in NVD database
Technical Details for CVE-2026-5769
Vulnerability Analysis
Brocade SANnav manages Fabric OS switches and stores administrative credentials used to authenticate against those switches. During normal runtime, these credentials reside in process memory. When the host operating system experiences memory pressure, the kernel swaps memory pages to the configured swap device or file on disk. Because SANnav does not lock or sanitize memory pages holding switch admin passwords, the plaintext credentials can be written to the swap file during an Out Of Memory event.
An authenticated administrator on the host operating system can then read the swap file offline and extract the captured credentials. The attack requires local access and high privileges on the hosting server, which limits scope but does not reduce the sensitivity of the exposed material.
Root Cause
The root cause is cleartext storage of sensitive authentication material in process memory that is eligible for paging. SANnav before 3.0.1 does not use memory-locking primitives such as mlock() or secure allocation routines that would prevent credential pages from being swapped to disk.
Attack Vector
Exploitation requires an authenticated administrative user on the server hosting the SANnav Virtual Machine. The attacker triggers or waits for an OOM condition that causes credential-bearing memory to be paged out, then reads the swap file directly from the host filesystem. No network interaction is required. Refer to the Broadcom Security Advisory #37934 for vendor details.
// No verified exploit code is available. The vulnerability manifests when
// OOM-triggered page swapping writes unlocked credential memory to disk,
// where a privileged local user can read /swapfile or /dev/swap contents.
Detection Methods for CVE-2026-5769
Indicators of Compromise
- Presence of OOM killer events in /var/log/messages or dmesg on the SANnav host coinciding with administrator access to swap storage
- Shell history or auditd records showing reads of /swapfile, /dev/sda* swap partitions, or copies of swap contents by administrators
- Unexpected authentication events on Fabric OS switches from source IP addresses associated with the SANnav host administrators
Detection Strategies
- Monitor file access on swap devices and swap files using the Linux audit subsystem (auditctl -w /swapfile -p rwa)
- Alert on process invocations of strings, dd, xxd, or grep against swap files or raw block devices
- Correlate OOM kernel events with subsequent privileged shell activity on the SANnav host
Monitoring Recommendations
- Enable centralized logging for the SANnav Virtual Machine host and forward kernel, audit, and shell logs to a SIEM
- Track Fabric OS switch admin logins and flag authentication from unexpected sources or outside maintenance windows
- Review privileged account activity on the SANnav host, including sudo invocations and root logins
How to Mitigate CVE-2026-5769
Immediate Actions Required
- Upgrade Brocade SANnav to version 3.0.1 or later as directed by Broadcom
- Rotate all Fabric OS switch admin passwords that have been stored in SANnav prior to the upgrade
- Restrict administrative access to the server hosting the SANnav Virtual Machine to a minimum set of personnel
Patch Information
Broadcom has addressed CVE-2026-5769 in Brocade SANnav 3.0.1. Apply the upgrade following the vendor instructions in Broadcom Security Advisory #37934. After upgrading, rotate any switch credentials that may have been written to swap on vulnerable hosts.
Workarounds
- Disable swap on the SANnav Virtual Machine host where operationally supported using swapoff -a and remove swap entries from /etc/fstab
- Encrypt the swap device so that offline reads of swap contents yield ciphertext rather than plaintext credentials
- Increase host memory allocation to reduce the likelihood of OOM-triggered page swapping of credential memory
- Restrict filesystem permissions on swap files and raw swap devices to the kernel and root only, and audit any administrator who requires elevated access
# Configuration example: disable swap and audit swap device access
sudo swapoff -a
sudo sed -i '/\sswap\s/d' /etc/fstab
sudo auditctl -w /swapfile -p rwa -k sannav_swap_access
Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.
Sources: National Vulnerability Database, CISA KEV, Exploit-DB