CVE-2026-102005: Wind River VxWorks 7 DoS Vulnerability

CVE-2026-102005 is a denial of service vulnerability in Wind River VxWorks 7 caused by a memory leak in specific service routines. This article covers the technical details, affected versions, and mitigation strategies.

Published:

Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.

Sources: National Vulnerability Database, CISA KEV, Exploit-DB

CVE-2026-102005 Overview

CVE-2026-102005 is a memory leak vulnerability [CWE-401] in Wind River VxWorks 7, affecting versions 24.03 through 26.03. The flaw occurs under specific, non-default configuration states when the real-time operating system (RTOS) processes certain service routines. The system terminates operations before releasing allocated memory pools, causing resource exhaustion. Wind River addressed the issue in VxWorks 7 26.09.

An authenticated local attacker can trigger the condition to exhaust system memory and degrade availability. Because VxWorks powers embedded and safety-critical devices, availability loss can cascade into operational disruption.

Critical Impact

A local, low-privileged attacker can exhaust memory in affected VxWorks 7 deployments, leading to denial of service on embedded systems and real-time control devices.

Affected Products

  • Wind River VxWorks 7 version 24.03
  • Wind River VxWorks 7 versions between 24.03 and 26.03
  • Wind River VxWorks 7 version 26.03

Discovery Timeline

  • 2026-09-28 - CVE-2026-102005 published to NVD
  • 2026-09-29 - Last updated in NVD database

Technical Details for CVE-2026-102005

Vulnerability Analysis

The vulnerability is a memory leak in the VxWorks 7 RTOS kernel. When specific service routines execute under non-default configuration states, the system terminates operations without freeing memory it previously allocated from kernel memory pools.

Repeated invocation of the affected code paths incrementally depletes available memory. On embedded systems with fixed, constrained memory budgets, this exhaustion halts task creation, disrupts scheduled workloads, and can force a watchdog reset.

The attack requires local access and low privileges, with no user interaction. Confidentiality and integrity are not impacted; the effect is limited to availability.

Root Cause

The root cause is improper release of allocated memory [CWE-401]. The affected service routines allocate memory pools during processing but exit early under specific configuration states, bypassing the code path that returns those pools to the allocator.

Because the leak only triggers in non-default configurations, deployments running stock settings are less exposed. Systems using the specific service routines with customized settings accumulate leaked allocations over time.

Attack Vector

Exploitation requires local access to the VxWorks device with valid low-privilege credentials or shell access. The attacker repeatedly invokes the vulnerable service routines under the triggering configuration state.

Each invocation leaks a memory pool. Sustained invocation exhausts kernel memory, resulting in denial of service. No public proof-of-concept is currently available, and the vulnerability is not listed in the CISA Known Exploited Vulnerabilities catalog.

The vulnerability is described in prose only; see the Wind River CVE Database for vendor-supplied technical detail.

Detection Methods for CVE-2026-102005

Indicators of Compromise

  • Progressive decline in free kernel memory reported by VxWorks memory diagnostic commands such as memShow and memPartShow.
  • Task creation failures, allocator errors, or watchdog-initiated resets on devices running affected VxWorks versions.
  • Repeated invocations of the affected service routines from a single local session or process.

Detection Strategies

  • Baseline free memory on VxWorks devices and alert on sustained downward trends that do not recover after workload completion.
  • Correlate memory exhaustion events with configuration changes that place the device into the non-default states referenced in the advisory.
  • Ingest VxWorks system logs into a centralized analytics platform to identify anomalous service routine invocation patterns.

Monitoring Recommendations

  • Monitor kernel memory pool utilization on a scheduled interval and generate alerts when thresholds are crossed.
  • Track local shell access and privileged command execution on embedded devices to detect abuse of low-privilege accounts.
  • Review device configuration state against a known-good baseline to detect transitions into vulnerable configurations.

How to Mitigate CVE-2026-102005

Immediate Actions Required

  • Inventory all Wind River VxWorks 7 deployments and identify systems running versions 24.03 through 26.03.
  • Restrict local access and enforce least-privilege on accounts that can reach the affected service routines.
  • Schedule upgrade to VxWorks 7 26.09 on affected devices, prioritizing systems in non-default configurations.

Patch Information

Wind River fixed CVE-2026-102005 in VxWorks 7 26.09. Refer to the Wind River CVE Database for release notes, patch packaging, and guidance on updating Board Support Packages (BSPs) and application images.

Workarounds

  • Revert affected devices to default configuration states where the vulnerable service routines do not trigger the leak.
  • Limit local user accounts and disable interactive shells on production devices where feasible.
  • Implement periodic device restarts to reclaim leaked memory until the 26.09 update is deployed.
bash
# Example: query VxWorks memory partition usage from the target shell
-> memShow
-> memPartShow sysMemPartId

Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.