CVE-2024-47563 Overview
Siemens disclosed CVE-2024-47563, a path traversal vulnerability [CWE-22] in SINEC Security Monitor affecting all versions prior to V4.9.0. The flaw resides in an endpoint intended to create Certificate Signing Request (CSR) files. The application does not properly validate the file path parameter supplied to this endpoint. An unauthenticated remote attacker can abuse the endpoint to create files in writable directories outside the intended location. This compromises the integrity of files in those directories and may serve as a foothold for subsequent attacks against the monitoring platform.
Critical Impact
Unauthenticated remote attackers can write files to arbitrary writable directories on the SINEC Security Monitor host, impacting file integrity across the system.
Affected Products
- Siemens SINEC Security Monitor, all versions prior to V4.9.0
- Deployments exposing the CSR creation endpoint to untrusted networks
- Industrial environments relying on SINEC Security Monitor for OT security monitoring
Discovery Timeline
- 2024-10-08 - CVE-2024-47563 published to the National Vulnerability Database (NVD)
- 2026-06-17 - Last updated in NVD database
Technical Details for CVE-2024-47563
Vulnerability Analysis
SINEC Security Monitor exposes an endpoint used to generate Certificate Signing Request files. The endpoint accepts a file path parameter that determines where the generated CSR is written. The application does not sanitize or constrain this parameter against directory traversal sequences or absolute paths. An attacker can supply a crafted path that resolves outside the intended CSR storage directory.
Because the endpoint does not require authentication, any remote actor with network reachability to the service can trigger the behavior. The resulting write operates with the privileges of the SINEC Security Monitor process. An attacker can overwrite or create configuration artifacts, drop scripts into locations monitored by other components, or stage payloads for later execution.
Root Cause
The root cause is improper limitation of a pathname to a restricted directory [CWE-22]. The CSR creation handler trusts caller-supplied path input and does not canonicalize or validate the final destination against an allowlist of writable base directories. Combined with the absence of authentication on the endpoint, the flaw yields a pre-auth arbitrary file write primitive bounded only by directories writable by the service account.
Attack Vector
Exploitation requires network access to the SINEC Security Monitor web interface. The attacker sends a request to the CSR creation endpoint with a path parameter containing directory traversal sequences such as ../ or an absolute path. The server resolves the path and writes the CSR content to the attacker-chosen location. No credentials, user interaction, or prior foothold are required. Refer to the Siemens Security Advisory SSA-430425 for protocol-level details.
Detection Methods for CVE-2024-47563
Indicators of Compromise
- Unexpected .csr or arbitrary files appearing in directories outside the designated SINEC Security Monitor CSR storage path
- HTTP requests to the CSR creation endpoint containing ../, ..\, URL-encoded traversal sequences (%2e%2e%2f), or absolute path arguments
- Modified timestamps on configuration files, scripts, or web-accessible directories owned by the SINEC service account
- Requests to the CSR endpoint from source addresses that are not administrative workstations
Detection Strategies
- Enable verbose web server access logging on the SINEC Security Monitor host and alert on CSR endpoint requests containing traversal patterns
- Deploy file integrity monitoring on directories writable by the SINEC service account to detect unauthorized file creation
- Correlate CSR endpoint access with source IP reputation and network segment to identify requests originating outside administrative subnets
Monitoring Recommendations
- Baseline normal CSR generation volume and alert on anomalous frequency or off-hours activity
- Forward SINEC Security Monitor application logs and host file system events to a centralized SIEM for correlation
- Monitor for new executables, scripts, or configuration overrides written to service directories after upgrades or restarts
How to Mitigate CVE-2024-47563
Immediate Actions Required
- Upgrade SINEC Security Monitor to V4.9.0 or later as directed in Siemens Security Advisory SSA-430425
- Restrict network access to the SINEC Security Monitor management interface to trusted administrative networks only
- Audit writable directories on the SINEC host for unauthorized files created since deployment
- Rotate any credentials, keys, or certificates that may have been exposed in writable locations
Patch Information
Siemens addressed CVE-2024-47563 in SINEC Security Monitor V4.9.0. Administrators should apply the vendor-supplied update and verify the version post-upgrade. Review the Siemens ProductCERT advisory SSA-430425 for the authoritative fix details and any additional conditions.
Workarounds
- Place the SINEC Security Monitor behind a reverse proxy or firewall that blocks requests to the CSR endpoint from untrusted sources
- Enforce network segmentation so only authorized OT security operators can reach the management interface
- Apply strict host-level file system permissions to limit directories writable by the SINEC service account
- Where upgrade is not immediate, monitor the CSR endpoint for traversal patterns and block offending clients at the perimeter
Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.
Sources: National Vulnerability Database, CISA KEV, Exploit-DB