Skip to main content
Vulnerability Database/CVE-2024-35209

CVE-2024-35209: Siemens Sinec Traffic Analyzer Privilege Escalation

CVE-2024-35209 is a privilege escalation vulnerability in Siemens Sinec Traffic Analyzer that allows attackers to modify unauthorized files through improper HTTP method handling. This article covers technical details, affected versions, security impact, and mitigation strategies.

Published:

Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.

Sources: National Vulnerability Database, CISA KEV, Exploit-DB

CVE-2024-35209 Overview

CVE-2024-35209 affects Siemens SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) in all versions prior to V1.2. The embedded web server exposes HTTP methods PUT and DELETE, which are not required for normal operation. An attacker with local network access to the device can abuse these methods to write or remove files on the server, resulting in unauthorized modification of application content. The weakness is categorized under CWE-749: Exposed Dangerous Method or Function. Siemens published advisory SSA-196737 describing the issue and a corresponding fix.

Critical Impact

Attackers can modify files on the SINEC Traffic Analyzer web server by issuing PUT or DELETE requests, compromising integrity of the industrial network monitoring platform.

Affected Products

  • Siemens SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) — all versions prior to V1.2
  • Siemens industrial Ethernet monitoring deployments relying on the SINEC Traffic Analyzer web interface
  • Operational Technology (OT) environments running the affected firmware for traffic analysis

Discovery Timeline

  • 2024-06-11 - CVE-2024-35209 published to the National Vulnerability Database (NVD)
  • 2024-06-11 - Siemens ProductCERT published advisory SSA-196737
  • 2026-06-17 - Last updated in NVD database

Technical Details for CVE-2024-35209

Vulnerability Analysis

The SINEC Traffic Analyzer web server accepts HTTP methods beyond those needed to serve its management interface. Specifically, the server permits PUT and DELETE requests against resources it hosts. These methods allow a client to upload a new resource at a specified URI or remove an existing resource from the server.

Because the server does not restrict or properly authorize these methods, an attacker with reachability to the web interface can alter files served by the appliance. This can include replacing legitimate content with attacker-controlled files or deleting files required for correct operation. The flaw is classified as CWE-749: Exposed Dangerous Method or Function.

Exploitation requires local network access to the device. The attack targets integrity rather than confidentiality or availability of the host operating system.

Root Cause

The root cause is an insecure web server configuration. The HTTP method allow list for the SINEC Traffic Analyzer management interface includes PUT and DELETE, which are not required for the product's documented management workflow. Combined with insufficient access control on these methods, the server exposes write and delete primitives to callers who can reach the interface.

Attack Vector

An attacker on a network segment that can reach the SINEC Traffic Analyzer web server sends an HTTP PUT request to upload or overwrite a file at a chosen path. A DELETE request removes an existing resource. No user interaction is required. The attacker needs network reachability to the appliance management interface; the CVSS vector classifies the attack vector as local to the appliance's management network.

No verified public exploit code is available for CVE-2024-35209. See Siemens advisory SSA-196737 for vendor-provided technical context.

// No verified exploit code is publicly available for CVE-2024-35209.
// Refer to Siemens Security Advisory SSA-196737 for vendor guidance.

Detection Methods for CVE-2024-35209

Indicators of Compromise

  • HTTP PUT or DELETE requests directed at the SINEC Traffic Analyzer management interface in web server access logs.
  • Unexpected creation, modification, or removal of files served by the appliance web root.
  • Changes to served pages, scripts, or configuration artifacts that do not correlate with authorized administrative actions.

Detection Strategies

  • Inspect appliance web server logs for request methods other than GET, HEAD, and POST.
  • Baseline file integrity on the SINEC Traffic Analyzer and alert on deviations from the known-good state after each patch window.
  • Deploy network sensors on the OT management VLAN to flag HTTP write methods aimed at engineering appliances.

Monitoring Recommendations

  • Forward appliance and surrounding network telemetry to a centralized analytics platform for correlation with authentication and change-management events.
  • Monitor for OPTIONS reconnaissance requests, which attackers commonly use to enumerate exposed HTTP methods before exploitation.
  • Track administrative sessions against the SINEC appliance and alert on sessions originating from unexpected source addresses.

How to Mitigate CVE-2024-35209

Immediate Actions Required

  • Update SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) to V1.2 or later per Siemens advisory SSA-196737.
  • Restrict access to the appliance management interface to a dedicated administration network and known administrator hosts.
  • Audit web server logs for prior PUT or DELETE activity and verify integrity of files served by the appliance.

Patch Information

Siemens addressed CVE-2024-35209 in SINEC Traffic Analyzer V1.2. Operators of the 6GK8822-1BG01-0BA0 appliance should upgrade to V1.2 or later. Refer to Siemens Security Advisory SSA-196737 for release artifacts and upgrade instructions.

Workarounds

  • Place the SINEC Traffic Analyzer behind a firewall or jump host that permits only GET, HEAD, and POST requests to the management interface.
  • Apply the Siemens operational guidelines for securing industrial devices, including network segmentation and defense-in-depth as described in the vendor advisory.
  • Limit management access to authenticated administrators on an isolated OT management VLAN until the patch can be deployed.
bash
# Example upstream firewall rule to block HTTP write methods toward the appliance
# (adapt to the enforcement point in your environment)
iptables -A FORWARD -d <SINEC_APPLIANCE_IP> -p tcp --dport 443 \
  -m string --algo bm --string "PUT " -j DROP
iptables -A FORWARD -d <SINEC_APPLIANCE_IP> -p tcp --dport 443 \
  -m string --algo bm --string "DELETE " -j DROP

Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.

Sources: National Vulnerability Database, CISA KEV, Exploit-DB

Experience the Most Advanced Cybersecurity Platform

See how the world’s most intelligent, autonomous cybersecurity platform can protect your organization today and into the future.