CVE-2024-41904 Overview
CVE-2024-41904 affects Siemens SINEC Traffic Analyzer (6GK8822-1BG01-0BA0), an industrial network monitoring appliance. The vulnerability stems from the application failing to enforce restrictions on excessive authentication attempts [CWE-307]. An unauthenticated remote attacker can launch brute force attacks against legitimate user credentials or keys without rate limiting or lockout enforcement. Siemens published advisory SSA-716317 covering this issue. All product versions prior to V2.0 are affected.
Critical Impact
Unauthenticated network-based brute force attacks can compromise valid user accounts on industrial network monitoring infrastructure, exposing sensitive operational technology (OT) traffic data.
Affected Products
- Siemens SINEC Traffic Analyzer (6GK8822-1BG01-0BA0)
- All versions prior to V2.0
- Industrial network monitoring deployments using the affected appliance
Discovery Timeline
- 2024-08-13 - CVE-2024-41904 published to NVD
- 2024-08-13 - Siemens releases security advisory SSA-716317
- 2026-06-17 - Last updated in NVD database
Technical Details for CVE-2024-41904
Vulnerability Analysis
The SINEC Traffic Analyzer authentication interface does not implement adequate controls against repeated authentication failures. Standard protections such as account lockout, progressive delays, CAPTCHA challenges, or IP-based throttling are absent or insufficient. Attackers can issue an unlimited number of authentication requests against the same account.
The vulnerability falls under [CWE-307] Improper Restriction of Excessive Authentication Attempts. Because the affected component is network-accessible and requires no prior authentication, an attacker only needs network reachability to the management interface. Successful credential discovery grants the attacker access to network traffic analysis data, which may include sensitive OT communications, device inventories, and protocol metadata.
Root Cause
The affected versions of the application lack a mechanism to track failed authentication attempts per account or per source. Without enforcement of attempt counters, time-based lockouts, or exponential backoff, the authentication endpoint accepts unlimited credential submissions. This design weakness directly enables credential guessing at network speed.
Attack Vector
An attacker with network access to the SINEC Traffic Analyzer management interface submits successive authentication requests using automated tools such as hydra, medusa, or custom scripts. Credential dictionaries, leaked password lists, or key material can be tested against valid usernames. No user interaction is required, and the attack proceeds entirely over the network. Weak or default passwords are recovered quickly under these conditions.
No public proof-of-concept exploit is currently available, and the vulnerability is not listed in the CISA Known Exploited Vulnerabilities catalog.
Detection Methods for CVE-2024-41904
Indicators of Compromise
- High volumes of failed authentication events in SINEC Traffic Analyzer logs originating from one or a small set of source IP addresses
- Successful authentication immediately following a burst of failures from the same source
- Authentication attempts occurring outside normal operational hours or from unexpected network segments
- Unusual session activity following credential validation, such as configuration access from non-administrator endpoints
Detection Strategies
- Ingest SINEC Traffic Analyzer authentication logs into a centralized SIEM and create rules thresholding failed login counts per source and per account
- Correlate authentication failures with subsequent successful logins to identify likely brute force compromise
- Baseline normal administrative access patterns and alert on deviations in source address, time, or frequency
Monitoring Recommendations
- Forward all management interface access logs to a centralized logging platform with long retention
- Monitor north-south traffic to the SINEC appliance for repeated TCP connections to the authentication endpoint
- Alert on authentication anomalies originating from non-management VLANs or external network segments
How to Mitigate CVE-2024-41904
Immediate Actions Required
- Upgrade SINEC Traffic Analyzer to version V2.0 or later as directed by Siemens advisory SSA-716317
- Restrict network access to the SINEC Traffic Analyzer management interface to a dedicated administrative network or jump host
- Enforce strong, unique passwords for all SINEC Traffic Analyzer accounts and rotate credentials suspected of exposure
- Review historical authentication logs for prior brute force activity
Patch Information
Siemens addresses CVE-2024-41904 in SINEC Traffic Analyzer V2.0. Customers should consult the Siemens Security Advisory SSA-716317 for official remediation guidance, download instructions, and any product-specific upgrade procedures.
Workarounds
- Place the SINEC Traffic Analyzer behind a network firewall that enforces source-IP restrictions on the management interface
- Apply network-layer rate limiting using a reverse proxy or firewall to throttle authentication attempts
- Disable or remove inactive accounts to reduce the attack surface available for credential guessing
- Implement multi-factor authentication on upstream identity providers where supported
# Example firewall rule restricting management access to a trusted subnet
iptables -A INPUT -p tcp --dport 443 -s 10.10.20.0/24 -j ACCEPT
iptables -A INPUT -p tcp --dport 443 -j DROP
Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.