CVE-2026-96274 is a denial of service vulnerability in Baicells Nova 430H eNodeB that allows unauthenticated attackers to disrupt cellular service by sending malformed uplink messages. This post covers technical details, impact, and mitigation.

Published:

Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.

Sources: National Vulnerability Database, CISA KEV, Exploit-DB

CVE-2026-96274 Overview

CVE-2026-96274 affects the Baicells Nova 430H eNodeB, a Long Term Evolution (LTE) small cell base station. An unauthenticated attacker within radio range can transmit a malformed uplink message during connection setup. The message contains an invalid Non-Access Stratum (NAS) payload that the eNodeB fails to validate before forwarding to the core network. The core network responds by shutting down the signaling association for the cell, disrupting service until connectivity is re-established. The vulnerability is tracked under [CWE-248: Uncaught Exception].

Critical Impact

A single malformed radio-frame injection can force a signaling association shutdown, disrupting LTE service for all subscribers attached to the affected cell.

Affected Products

  • Baicells Nova 430H eNodeB
  • Deployments using the affected Nova 430H radio firmware
  • LTE small cell environments relying on Nova 430H for signaling

Discovery Timeline

  • 2026-09-29 - CVE-2026-96274 published to the National Vulnerability Database (NVD)
  • 2026-09-29 - Last updated in NVD database
  • 2026-09-29 - CISA released ICS Advisory ICSA-26-272-04

Technical Details for CVE-2026-96274

Vulnerability Analysis

The Baicells Nova 430H eNodeB accepts uplink Radio Resource Control (RRC) messages during User Equipment (UE) connection setup. These messages encapsulate a NAS payload destined for the Mobility Management Entity (MME) in the Evolved Packet Core (EPC). The eNodeB acts as a relay for NAS signaling and is expected to sanity-check the encapsulated payload before forwarding it over the S1-MME interface. In this case, the eNodeB does not properly validate the NAS payload structure. When the malformed payload reaches the MME, the resulting parsing error triggers a shutdown of the Stream Control Transmission Protocol (SCTP) signaling association for the cell. All attached subscribers lose service until the eNodeB and core network re-establish the S1 association.

Root Cause

The root cause is an uncaught exception condition [CWE-248] on the S1-MME signaling path. The eNodeB forwards attacker-controlled NAS content without enforcing structural validation, and the downstream core network component does not gracefully handle the resulting parse failure.

Attack Vector

Exploitation requires radio proximity to the target cell. An adversary transmits a crafted RRC Connection Setup Complete message containing an invalid NAS payload. No credentials, subscriber identity, or prior attachment are required. The attack does not require SIM provisioning against the target network because the malformed frame is processed before authentication completes. Refer to CISA ICS Advisory ICSA-26-272-04 for the authoritative technical description.

No verified proof-of-concept code is publicly available.
See CISA ICSA-26-272-04 for the vendor-coordinated technical description.

Detection Methods for CVE-2026-96274

Indicators of Compromise

  • Unexpected S1AP or SCTP association resets on the S1-MME interface between the Nova 430H eNodeB and the MME
  • Repeated RRC Connection Setup Complete events from unknown or unattached UEs followed by cell-wide service loss
  • Correlated subscriber detach and reattach storms coinciding with core-network signaling errors

Detection Strategies

  • Baseline normal S1 association uptime per cell and alert on abnormal SCTP shutdown or INIT sequences
  • Inspect MME logs for NAS decoding exceptions tied to a specific eNodeB identifier
  • Correlate radio-side RRC anomalies with core-side signaling faults to distinguish attacks from routine outages

Monitoring Recommendations

  • Enable verbose S1AP and NAS protocol logging on the MME during triage windows
  • Forward eNodeB and core-network signaling telemetry to a centralized analytics platform for correlation
  • Monitor cell-level availability metrics and page volumes to detect the temporary service disruption pattern described in the advisory

How to Mitigate CVE-2026-96274

Immediate Actions Required

  • Review CISA ICSA-26-272-04 and apply vendor guidance for the Baicells Nova 430H
  • Inventory all Nova 430H eNodeBs and confirm firmware version against the advisory
  • Restrict physical and radio-frequency access to areas surrounding deployed small cells where feasible

Patch Information

Refer to Baicells and the CISA ICS Advisory ICSA-26-272-04 for the current remediation status and firmware update availability for the Nova 430H.

Workarounds

  • Deploy RF monitoring to identify rogue transmitters operating near affected cells
  • Configure automated S1 association recovery and health checks to minimize disruption duration
  • Segment and monitor S1-MME traffic so that core-network signaling faults are rapidly attributed to a specific eNodeB
bash
# Example: monitor SCTP associations to the MME on a Linux-based EPC host
watch -n 5 'ss -S state established | grep :36412'

# Example: capture S1AP traffic for offline NAS payload inspection
tcpdump -i eth0 -w s1ap.pcap 'sctp and port 36412'