Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.
Sources: National Vulnerability Database, CISA KEV, Exploit-DB
CVE-2026-93262 Overview
CVE-2026-93262 is a use-after-free vulnerability in the Linux kernel's md/raid5-ppl subsystem. The flaw resides in the ppl_do_flush() function, where the iteration loop continues after calling ppl_io_unit_finished(). The loop then accesses io->pending_flushes on freed memory, triggering a use-after-free condition. A local authenticated attacker with low privileges can exploit this flaw to corrupt kernel memory, escalate privileges, or crash the system. The upstream fix adds a break statement to terminate the loop once the io object is freed.
Critical Impact
Local privilege escalation and kernel memory corruption on systems using RAID5 with Partial Parity Log (PPL) enabled.
Affected Products
- Linux kernel builds with the md/raid5-ppl driver compiled in
- Distributions shipping affected stable kernel branches referenced in the upstream patch series
- Storage systems using RAID5 arrays with Partial Parity Log (PPL) enabled
Discovery Timeline
- 2026-09-24 - CVE-2026-93262 published to NVD
- 2026-09-25 - Last updated in NVD database
Technical Details for CVE-2026-93262
Vulnerability Analysis
The vulnerability affects the Partial Parity Log (PPL) implementation within the Linux kernel's software RAID5 driver. PPL is used to close the RAID5 write hole by logging partial parity data before writes commit to the array. The ppl_do_flush() function iterates over pending I/O units and issues flush operations to backing devices.
When ppl_io_unit_finished() is invoked inside this loop, it can free the io structure. The loop control then dereferences io->pending_flushes on the freed allocation. This classifies as a use-after-free [CWE-416] in kernel space.
Successful exploitation grants an attacker control over freed kernel memory. This can lead to arbitrary kernel read/write primitives, privilege escalation, or a denial-of-service condition through kernel panic.
Root Cause
The root cause is missing loop termination after the io object is released. The developer did not break out of the iteration after ppl_io_unit_finished() potentially freed the structure. Any subsequent field access on io operates on reclaimed memory, which may already hold attacker-influenced data if a parallel allocation reuses the slab object.
Attack Vector
Exploitation requires local access with low privileges on a system running an affected kernel with RAID5 PPL enabled. The attacker must trigger flush operations against a PPL-backed RAID5 array under conditions that free an I/O unit mid-iteration. Reliable exploitation typically involves heap grooming of the kernel slab cache to replace the freed object with attacker-controlled data.
No public proof-of-concept exploit is available at this time, and the vulnerability is not listed in the CISA Known Exploited Vulnerabilities catalog. The vulnerability is described in prose only; the upstream fix adds a break statement after the free. See the kernel patch commits for implementation details.
Detection Methods for CVE-2026-93262
Indicators of Compromise
- Kernel panic or oops messages referencing ppl_do_flush, ppl_io_unit_finished, or raid5-ppl in dmesg and /var/log/kern.log
- KASAN (Kernel Address Sanitizer) reports flagging use-after-free in the md/raid5-ppl module on debug kernels
- Unexpected RAID5 array degradation or inconsistent parity states on PPL-enabled arrays
Detection Strategies
- Audit running kernel versions across the fleet against the fixed commits listed in the stable tree references
- Enumerate RAID arrays using mdadm --detail /dev/mdX to identify RAID5 volumes with PPL enabled
- Enable KASAN on test and staging kernels to surface use-after-free conditions during QA
Monitoring Recommendations
- Forward kernel ring buffer logs to a central SIEM and alert on crash signatures that reference raid5-ppl symbols
- Monitor process-crash and kernel-panic telemetry on Linux hosts, particularly storage servers and database nodes using software RAID
- Track privilege escalation events and unexpected root-shell spawns following suspicious kernel log activity
How to Mitigate CVE-2026-93262
Immediate Actions Required
- Apply the vendor-provided kernel update that includes the upstream fix for ppl_do_flush()
- Inventory systems using software RAID5 with PPL and prioritize patching those hosts
- Restrict local shell access on affected systems to trusted administrators until patches are deployed
Patch Information
The fix adds a break statement after ppl_io_unit_finished() to prevent further iteration on freed memory. Relevant upstream commits include 371f7a1, 455b562, 8914c3d, b5123bf, cf01f94, e750584, e77c806, and fcf21df. Rebuild and reboot into the patched kernel for the fix to take effect.
Workarounds
- Disable Partial Parity Log on affected RAID5 arrays where operationally feasible using mdadm --grow --consistency-policy=resync /dev/mdX
- Blacklist the raid456 module on systems that do not require software RAID5 functionality
- Enforce strict local-user access controls and limit unprivileged users on storage hosts to reduce the attack surface
Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.
Sources: National Vulnerability Database, CISA KEV, Exploit-DB