Skip to main content
Vulnerability Database/CVE-2026-79963

CVE-2026-79963: Dell Secure Connect Gateway RCE Vulnerability

CVE-2026-79963 is a remote code execution vulnerability in Dell Secure Connect Gateway that allows unauthenticated attackers to execute commands remotely. This article covers technical details, affected versions, impact, and mitigation.

Published:

CVE-2026-79963 Overview

CVE-2026-79963 affects Dell Secure Connect Gateway (SCG) 5.0, a remote support and telemetry appliance used to connect Dell infrastructure to Dell support services. The flaw is a Download of Code Without Integrity Check weakness [CWE-494] in both the SCG 5.0 Appliance and SCG 5.0 Application. An unauthenticated remote attacker can exploit the missing integrity validation to deliver attacker-controlled code, which the gateway then executes. Successful exploitation results in command execution on the affected appliance, compromising integrity and availability of the device.

Critical Impact

Unauthenticated remote attackers can achieve command execution on the Dell SCG appliance by supplying code that the gateway loads without integrity verification.

Affected Products

  • Dell Secure Connect Gateway 5.0 Appliance versions prior to 5.36.00.16
  • Dell Secure Connect Gateway 5.0 Application versions prior to 5.36.00.00
  • Dell SCG Virtual Edition deployments covered by advisory DSA-2026-382

Discovery Timeline

  • 2026-09-09 - CVE-2026-79963 published to NVD
  • 2026-09-09 - Dell publishes security advisory DSA-2026-382
  • 2026-09-09 - Last updated in NVD database

Technical Details for CVE-2026-79963

Vulnerability Analysis

Dell Secure Connect Gateway acts as the communication bridge between Dell customer environments and Dell backend services for telemetry, log collection, and remote support. The vulnerability arises because the appliance retrieves code, such as updates or auxiliary components, without validating the integrity or authenticity of the downloaded content. An attacker positioned to influence the download flow can substitute malicious code that the gateway subsequently executes with the privileges of the SCG service.

Because the attack vector is network-based and requires no authentication or user interaction, any exposure of the SCG management or update channels increases risk. The high attack complexity reflects the conditions the attacker must meet to influence the download, such as network positioning or manipulation of update endpoints.

Root Cause

The root cause is a missing cryptographic integrity check on downloaded code, mapped to [CWE-494]. Without signature verification or trusted checksum validation, the gateway treats retrieved payloads as authentic and loads them into its execution context.

Attack Vector

Exploitation requires the attacker to control or tamper with the code the SCG appliance downloads. Once delivered, the unverified payload is executed by the appliance, resulting in command execution. No credentials or user interaction are required. Refer to Dell advisory DSA-2026-382 for vendor-provided technical context.

Detection Methods for CVE-2026-79963

Indicators of Compromise

  • Unexpected outbound connections from the SCG appliance to non-Dell domains or IP ranges during update or telemetry operations.
  • New or modified binaries, scripts, or service definitions on the SCG appliance filesystem outside vendor patch windows.
  • Unusual child processes spawned by SCG service accounts, especially shells or network utilities.

Detection Strategies

  • Compare installed SCG Appliance and Application versions against fixed builds 5.36.00.16 and 5.36.00.00 respectively.
  • Inspect SCG update logs for downloads from unexpected sources or with integrity or signature errors that were ignored.
  • Alert on process execution anomalies on the appliance, such as SCG services launching interpreters or reverse-shell tooling.

Monitoring Recommendations

  • Baseline network egress from SCG appliances and alert on deviations from documented Dell endpoints.
  • Forward SCG appliance logs to a centralized SIEM for correlation with endpoint and network telemetry.
  • Monitor for privilege changes, new local accounts, or scheduled tasks created on SCG hosts.

How to Mitigate CVE-2026-79963

Immediate Actions Required

  • Upgrade Dell SCG 5.0 Appliance to version 5.36.00.16 or later.
  • Upgrade Dell SCG 5.0 Application to version 5.36.00.00 or later.
  • Restrict inbound and outbound network access for the SCG appliance to Dell-required endpoints only.
  • Review SCG appliance integrity, logs, and configuration for signs of prior tampering.

Patch Information

Dell has released fixed builds in advisory DSA-2026-382. Apply the vendor-supplied updates through the standard SCG update process and verify the reported version after upgrade.

Workarounds

  • Isolate SCG appliances on a dedicated management network segment with strict egress filtering.
  • Block SCG communication with any non-Dell update or telemetry endpoints at the perimeter firewall.
  • Disable or pause automatic update functionality until the patched version is installed if operational policy allows.
bash
# Verify SCG appliance version after applying the DSA-2026-382 update
scgcli system version
# Expected output: appliance version >= 5.36.00.16, application version >= 5.36.00.00

Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.

Experience the Most Advanced Cybersecurity Platform

See how the world’s most intelligent, autonomous cybersecurity platform can protect your organization today and into the future.