CVE-2026-76664 Overview
CVE-2026-76664 is an out-of-bounds read/write vulnerability affecting HPE NonStop EXPAND. The flaw is classified under [CWE-125] (Out-of-bounds Read) and allows an attacker on an adjacent network to trigger memory access outside intended bounds. Successful exploitation can expose limited confidential data, modify limited integrity-protected content, and cause high-impact availability loss on the affected NonStop system. HPE published a security bulletin tracking the issue under reference hpesbns05148en_us. No public proof-of-concept exploit, exploitation in the wild, or CISA KEV listing has been reported for this CVE at the time of publication.
Critical Impact
An adjacent-network attacker can trigger out-of-bounds memory reads and writes in HPE NonStop EXPAND, risking information disclosure, data tampering, and service disruption on NonStop fault-tolerant systems.
Affected Products
- HPE NonStop EXPAND (specific affected versions listed in HPE Security Bulletin hpesbns05148en_us)
- HPE NonStop systems running vulnerable EXPAND networking subsystem builds
- Deployments where NonStop nodes communicate over EXPAND across adjacent network segments
Discovery Timeline
- 2026-10-15 - CVE CVE-2026-76664 published to the National Vulnerability Database
- 2026-10-15 - Last updated in NVD database
Technical Details for CVE-2026-76664
Vulnerability Analysis
The vulnerability resides in HPE NonStop EXPAND, the networking subsystem that connects NonStop nodes into a wide-area or multi-node network. The weakness is categorized as [CWE-125] Out-of-bounds Read, with the HPE bulletin also indicating out-of-bounds write behavior. EXPAND processes network frames to route traffic between NonStop systems, and improper bounds validation during this processing lets a malformed message read or write memory outside the intended buffer region. The attack surface is limited to adjacent-network access, meaning an attacker typically needs a foothold on the same logical network segment as the EXPAND interface. HPE documents the issue in the HPE Security Bulletin, which is the authoritative source for affected release-version updates (RVUs) and remediation.
Root Cause
The root cause is missing or incomplete validation of length or offset fields in network messages handled by EXPAND. When EXPAND parses attacker-controlled fields without enforcing buffer boundaries, subsequent memory operations read or write past the end of the intended buffer. This matches the behavior described by [CWE-125] and the write component referenced in the bulletin.
Attack Vector
Exploitation requires network adjacency and no authentication or user interaction. An attacker able to deliver crafted EXPAND traffic to a vulnerable NonStop interface can trigger the out-of-bounds access. High attack complexity reflects the specialized protocol knowledge and timing conditions required. Impact is weighted toward availability, consistent with service disruption on EXPAND-connected NonStop nodes.
No verified public exploit code is available. Refer to the HPE Security Bulletin for the technical description.
Detection Methods for CVE-2026-76664
Indicators of Compromise
- Unexpected restarts, process pair failovers, or EXPAND line handler aborts on NonStop nodes
- EMS (Event Management Service) events indicating malformed EXPAND packets or protocol errors
- Anomalous EXPAND frames from hosts on adjacent network segments that do not match known NonStop peers
Detection Strategies
- Inspect EMS logs for EXPAND subsystem errors, line handler terminations, and memory access faults correlated with inbound network activity
- Baseline normal EXPAND peer relationships and alert on EXPAND traffic originating from unauthorized sources on adjacent VLANs
- Deploy network monitoring on segments carrying EXPAND traffic to flag malformed or oversized protocol frames
Monitoring Recommendations
- Forward NonStop EMS and SAFEGUARD audit data to a centralized analytics platform for correlation with network telemetry
- Monitor the integrity and uptime of EXPAND line handlers and process pairs continuously
- Track configuration changes to EXPAND lines, SUPER paths, and access control lists on NonStop systems
How to Mitigate CVE-2026-76664
Immediate Actions Required
- Review the HPE Security Bulletin and identify NonStop systems running affected EXPAND versions
- Apply the HPE-provided SPR (Software Product Revision) or RVU update as listed in the bulletin
- Restrict adjacent-network access to EXPAND interfaces to known NonStop peers only
Patch Information
HPE has released remediation guidance in Security Bulletin hpesbns05148en_us. Customers should consult the bulletin for the specific affected EXPAND SPR levels and the corresponding fixed releases. Patching should follow standard NonStop change-control procedures, including validation on non-production nodes before fleet-wide rollout.
Workarounds
- Enforce network segmentation so EXPAND traffic traverses only trusted, isolated VLANs or dedicated interconnects
- Apply access control lists on upstream switches and routers to permit EXPAND protocol traffic only between authorized NonStop endpoints
- Disable or restrict unused EXPAND lines and interfaces until patches are applied
# Configuration example
# Illustrative ACL concept restricting EXPAND traffic to known NonStop peers.
# Replace addresses and interface names to match your environment.
#
# Permit EXPAND traffic only between authorized NonStop nodes
access-list EXPAND-ALLOW permit ip host <nonstop-node-A> host <nonstop-node-B>
access-list EXPAND-ALLOW deny ip any any log
#
# Apply to the interface carrying EXPAND adjacency
interface <expand-segment-interface>
ip access-group EXPAND-ALLOW in
Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.
Sources: National Vulnerability Database, CISA KEV, Exploit-DB