Skip to main content
Vulnerability Database/CVE-2026-76655

CVE-2026-76655: HPE NonStop SNMP Trap Multiplexer RCE Flaw

CVE-2026-76655 is a remote code execution vulnerability in HPE NonStop SNMP Trap Multiplexer that enables attackers to execute arbitrary code remotely. This article covers technical analysis, affected versions, and mitigation.

Published:

Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.

Sources: National Vulnerability Database, CISA KEV, Exploit-DB

CVE-2026-76655 Overview

CVE-2026-76655 is a stack-based buffer overflow [CWE-121] in the Hewlett Packard Enterprise (HPE) NonStop SNMP Trap Multiplexer. The flaw is reachable over the network without authentication or user interaction. Successful exploitation causes a high-impact denial of service against the affected service.

The weakness resides in trap-processing logic exposed by the Simple Network Management Protocol (SNMP) multiplexer component on HPE NonStop systems. Attackers can send crafted SNMP traffic to trigger the overflow condition. HPE published a security bulletin describing the issue and remediation.

Critical Impact

An unauthenticated remote attacker can disrupt availability of the HPE NonStop SNMP Trap Multiplexer service by sending malicious network traffic.

Affected Products

  • HPE NonStop SNMP Trap Multiplexer (specific versions listed in the HPE security bulletin)
  • HPE NonStop operating environments running the vulnerable multiplexer component
  • Refer to the HPE Security Bulletin for the authoritative list of affected builds

Discovery Timeline

  • 2026-10-14 - CVE-2026-76655 published to the National Vulnerability Database (NVD)
  • 2026-10-14 - Last updated in NVD database

Technical Details for CVE-2026-76655

Vulnerability Analysis

The vulnerability is a stack-based buffer overflow in the SNMP Trap Multiplexer, the HPE NonStop component responsible for receiving and relaying SNMP trap messages. The service accepts network input and copies data into a fixed-size stack buffer without adequate length validation. When input exceeds the expected size, adjacent stack memory is overwritten.

The NVD metrics describe the realized impact as availability loss only, with no confidentiality or integrity consequences. In practice, the overflow corrupts stack state and crashes the trap multiplexer process. The HPE advisory frames the broader risk as potential remote code execution, which reflects the general exploitability class of stack overflows in [CWE-121].

Root Cause

The root cause is missing bounds checking during the parsing of inbound SNMP trap data. The multiplexer trusts attacker-controlled length or content fields and writes beyond the allocated stack buffer. This pattern is the defining characteristic of [CWE-121] Stack-Based Buffer Overflow.

Attack Vector

The attack vector is network based. An attacker who can reach the UDP port used by the SNMP Trap Multiplexer, typically UDP/162, can deliver a malformed trap packet. No credentials and no user interaction are required. Any network path to the listener, including from adjacent management networks, is sufficient to trigger the condition.

No verified proof-of-concept code or public exploit has been published. See the HPE Security Bulletin for vendor-provided technical details.

Stop Remote Code Execution Before It Runs

Singularity™ Endpoint detects and blocks exploit attempts at machine speed, including zero-days and novel attack techniques.

Stop Exploit Attempts

Detection Methods for CVE-2026-76655

Indicators of Compromise

  • Unexpected termination or restart of the SNMP Trap Multiplexer process on HPE NonStop systems
  • Malformed SNMP trap packets received on UDP/162 from untrusted sources
  • Gaps in trap forwarding or loss of downstream SNMP event visibility correlating with inbound traffic bursts

Detection Strategies

  • Inspect SNMP trap traffic for oversized variable bindings and malformed Abstract Syntax Notation One (ASN.1) encodings
  • Alert on repeated process crashes or core dumps associated with the trap multiplexer binary
  • Baseline normal SNMP trap sources and flag traffic from unexpected hosts targeting management interfaces

Monitoring Recommendations

  • Forward NonStop system event logs and process health telemetry to a centralized logging platform for correlation
  • Monitor UDP/162 flow records at network boundaries for anomalous packet sizes or source addresses
  • Track service availability of the SNMP Trap Multiplexer with synthetic health checks

How to Mitigate CVE-2026-76655

Immediate Actions Required

  • Apply the HPE-supplied update identified in the HPE Security Bulletin for the SNMP Trap Multiplexer
  • Restrict network reachability of UDP/162 on NonStop systems to known, trusted SNMP sources only
  • Audit management network segmentation to ensure the trap multiplexer is not exposed to general corporate or internet-facing networks

Patch Information

HPE has published remediation guidance in security bulletin hpesbns05148en_us. Administrators should consult the bulletin for the fixed release numbers that correspond to their deployed HPE NonStop environment and apply the vendor-provided update.

Workarounds

  • Use host-based or network firewall rules to permit SNMP trap traffic only from authorized network management stations
  • Disable the SNMP Trap Multiplexer where it is not operationally required until the patch is applied
  • Place SNMP management traffic on a dedicated, access-controlled out-of-band network

Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.

Sources: National Vulnerability Database, CISA KEV, Exploit-DB

Experience the Most Advanced Cybersecurity Platform

See how the world’s most intelligent, autonomous cybersecurity platform can protect your organization today and into the future.