Skip to main content
CVE Vulnerability Database
Vulnerability Database/CVE-2026-50061

CVE-2026-50061: Solid Edge Use-After-Free Vulnerability

CVE-2026-50061 is a use-after-free vulnerability in Solid Edge SE2025 and SE2026 that enables code execution via malicious DFT files. This article covers technical details, affected versions, impact, and mitigation.

Published:

CVE-2026-50061 Overview

CVE-2026-50061 is a use-after-free vulnerability [CWE-416] in Siemens Solid Edge affecting the parser for DFT (Draft) files. An attacker who convinces a user to open a crafted DFT file can trigger the flaw and execute arbitrary code in the context of the current process. The issue affects Solid Edge SE2025 versions prior to V225.0 Update 15 and Solid Edge SE2026 versions prior to V226.0 Update 7. Siemens ProductCERT documented the flaw in advisory SSA-621657.

Critical Impact

Successful exploitation grants arbitrary code execution in the context of the Solid Edge process, enabling data theft, engineering IP compromise, and lateral movement on engineering workstations.

Affected Products

  • Siemens Solid Edge SE2025 (all versions prior to V225.0 Update 15)
  • Siemens Solid Edge SE2026 (all versions prior to V226.0 Update 7)
  • Workstations processing untrusted DFT files

Discovery Timeline

  • 2026-08-11 - CVE-2026-50061 published to NVD
  • 2026-08-11 - Last updated in NVD database

Technical Details for CVE-2026-50061

Vulnerability Analysis

The vulnerability resides in the code path that parses Solid Edge DFT files. During parsing, the application frees a memory object but retains a dangling pointer that is later dereferenced. An attacker who controls the file contents can shape the reused heap region and redirect execution flow when the dangling pointer is used. Because Solid Edge runs with the privileges of the invoking user, code execution occurs in the security context of the engineer opening the file.

Exploitation requires local file delivery and user interaction to open the crafted file. Attack complexity is elevated because the attacker must align heap state to reliably reclaim the freed object. Successful exploitation compromises confidentiality, integrity, and availability of the workstation session.

Root Cause

The root cause is a use-after-free condition [CWE-416] in the DFT file parser. The application releases a heap allocation while a reference to that memory remains reachable in later parsing logic. When the parser dereferences the stale pointer, attacker-controlled data placed in the reclaimed allocation drives program behavior, including virtual method dispatch or object field access that yields control-flow hijack.

Attack Vector

The attack vector is local and requires user interaction. A typical scenario involves phishing an engineer with a malicious DFT file attachment, hosting the file on a shared engineering repository, or planting it in a project folder. When the user opens the file in a vulnerable Solid Edge build, the parser reaches the flawed code path and the attacker gains code execution in the user context. No authentication to Solid Edge is required beyond the user's existing session. Refer to the Siemens Security Advisory SSA-621657 for vendor technical details.

Detection Methods for CVE-2026-50061

Indicators of Compromise

  • Unexpected child processes spawned by Edge.exe or related Solid Edge binaries, particularly command interpreters such as cmd.exe, powershell.exe, or rundll32.exe.
  • Crashes of Solid Edge with access violation exceptions correlated with opening .dft files from untrusted sources.
  • DFT files delivered via email, external drives, or shared network paths that were not produced by known internal engineering workflows.

Detection Strategies

  • Monitor process lineage on engineering workstations for anomalous descendants of Solid Edge processes and alert on script interpreter or LOLBAS execution.
  • Inspect Windows Error Reporting and application crash telemetry for repeated Solid Edge faults tied to DFT file opens, which may indicate exploitation attempts or fuzzing.
  • Apply file reputation and sandbox analysis to inbound DFT files at the email and web proxy layers.

Monitoring Recommendations

  • Centralize endpoint and application telemetry from CAD workstations into your SIEM or data lake to enable correlation of crash, process, and file events.
  • Track installed Solid Edge versions across the fleet and alert on hosts running builds earlier than V225.0 Update 15 or V226.0 Update 7.
  • Baseline normal parent-child relationships for Edge.exe and generate detections for deviations that indicate post-exploitation activity.

How to Mitigate CVE-2026-50061

Immediate Actions Required

  • Upgrade Solid Edge SE2025 to V225.0 Update 15 or later, and Solid Edge SE2026 to V226.0 Update 7 or later.
  • Restrict opening of DFT files to those originating from trusted internal sources and validated project repositories.
  • Communicate the risk to engineering users and instruct them not to open unsolicited DFT files.

Patch Information

Siemens has released fixed versions addressing this issue. Update Solid Edge SE2025 to V225.0 Update 15 and Solid Edge SE2026 to V226.0 Update 7. Full remediation details are available in the Siemens Security Advisory SSA-621657.

Workarounds

  • Only process DFT files received from trusted sources and verify their origin before opening.
  • Isolate CAD workstations that cannot be patched immediately using network segmentation and restricted user privileges.
  • Enable application-layer sandboxing or attachment detonation for engineering file formats delivered via email or collaboration tools.

Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.

Default Legacy - Prefooter | Experience the World’s Most Advanced Cybersecurity Platform

Experience the Most Advanced Cybersecurity Platform

See how the world’s most intelligent, autonomous cybersecurity platform can protect your organization today and into the future.