CVE-2026-42969 Overview
CVE-2026-42969 is an information disclosure vulnerability in the Windows Push Notifications component. The flaw stems from the use of an uninitialized resource [CWE-908], which an authorized local attacker can leverage to read memory contents that should remain inaccessible. Exploitation requires local access and low privileges, and no user interaction is needed.
Successful exploitation results in disclosure of sensitive information from process memory. The vulnerability does not affect integrity or availability of the host. Microsoft has documented the issue in its security update guide and released fixes through the standard Windows servicing channel.
Critical Impact
An authorized local attacker can read uninitialized memory from the Windows Push Notifications service, exposing sensitive data that may include credentials, tokens, or pointers usable in follow-on attacks.
Affected Products
- Microsoft Windows (Push Notifications component)
- Refer to the Microsoft Security Update Guide for the authoritative list of affected builds
- Both client and server Windows editions that include the Push Notifications service are in scope per Microsoft's advisory
Discovery Timeline
- 2026-06-09 - CVE-2026-42969 published to the National Vulnerability Database
- 2026-06-09 - Last updated in NVD database
Technical Details for CVE-2026-42969
Vulnerability Analysis
The vulnerability resides in the Windows Push Notifications subsystem, which delivers toast notifications and background events to UWP and desktop applications. The component allocates a resource — typically a memory buffer or structure — and uses it before all fields have been explicitly initialized. When that resource is returned across a trust boundary or read by a lower-privileged caller, residual memory contents leak to the attacker.
The issue maps to [CWE-908] Use of Uninitialized Resource. The leaked bytes can contain kernel pointers, heap metadata, authentication artifacts, or fragments of other applications' data that previously occupied the same memory. Attackers commonly chain such leaks with memory corruption bugs to bypass Address Space Layout Randomization (ASLR).
Root Cause
The root cause is a code path that allocates a structure and populates only a subset of its members before returning it to a caller. The remaining bytes retain whatever the allocator previously held. Because the Push Notifications service handles requests from user-mode processes, contents from higher-privileged contexts can cross into attacker-readable memory.
Attack Vector
An attacker must already be authenticated on the target system with standard user privileges. The attacker invokes the affected Push Notifications interfaces from a local process and inspects the returned data for residual memory. No network access, no elevated privileges, and no user interaction are required. Refer to the Microsoft Security Update CVE-2026-42969 advisory for component-level details.
Detection Methods for CVE-2026-42969
Indicators of Compromise
- No public indicators of compromise have been published for CVE-2026-42969 at the time of writing.
- Unexpected child processes spawned by WpnUserService or wpnservice.dll-hosted processes warrant review.
- Local processes making unusual or repeated calls into Windows Push Notifications APIs from non-notification-aware applications.
Detection Strategies
- Hunt for low-privilege processes that load Windows Push Notifications client libraries and then write large volumes of binary data to disk or transmit it over the network.
- Correlate Windows Defender Application Control or AppLocker telemetry with calls to push notification interfaces from unsigned or unusual binaries.
- Baseline normal callers of the Push Notifications service and alert on deviations.
Monitoring Recommendations
- Enable Windows process creation auditing (Event ID 4688) with command-line logging to capture local enumeration tools.
- Forward Sysmon Event IDs 1, 7, and 10 to a centralized data lake to capture process, module load, and process access activity targeting the Push Notifications service.
- Track patch deployment status across endpoints to confirm the June 2026 update has been applied.
How to Mitigate CVE-2026-42969
Immediate Actions Required
- Deploy the Microsoft security update referenced in the MSRC advisory for CVE-2026-42969 to all Windows systems.
- Prioritize multi-user systems such as Remote Desktop Session Hosts and Virtual Desktop Infrastructure where local-privilege information disclosure has the broadest impact.
- Audit local accounts and remove unnecessary interactive logon rights to reduce the attacker population able to reach the affected code path.
Patch Information
Microsoft has issued an official fix through the Windows Update channel. Administrators should apply the cumulative update that addresses CVE-2026-42969 via Windows Server Update Services (WSUS), Microsoft Intune, or Configuration Manager. Validate installation by confirming the post-patch build number against the version table in the Microsoft Security Update Guide.
Workarounds
- No vendor-supplied workaround is documented; patching is the only supported remediation.
- Restrict interactive and remote-interactive logon to trusted administrators where business requirements allow, reducing exposure until patches are deployed.
- Apply application allowlisting to prevent untrusted binaries from invoking Push Notifications APIs on sensitive hosts.
# Verify the Windows Push Notifications update is installed (PowerShell)
Get-HotFix | Sort-Object -Property InstalledOn -Descending | Select-Object -First 10
# Confirm the WpnUserService is running and patched binaries are loaded
Get-Service -Name WpnUserService*
Get-Item C:\Windows\System32\wpnservice.dll | Select-Object VersionInfo
Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.

