Skip to main content
CVE Vulnerability Database
Vulnerability Database/CVE-2026-16890

CVE-2026-16890: IBM VIOS Information Disclosure Flaw

CVE-2026-16890 is an information disclosure vulnerability in IBM PowerVM VIOS caused by an integer overflow. Local attackers can exploit this flaw to access sensitive data or trigger denial of service. Learn about affected versions and mitigation.

Updated:

CVE-2026-16890 Overview

CVE-2026-16890 is an integer overflow vulnerability [CWE-190] affecting IBM AIX 7.2, IBM AIX 7.3, and IBM PowerVM VIOS 4.1. A local, authenticated attacker can trigger the overflow to read sensitive information from memory or cause a denial of service condition. The flaw requires local access with low privileges and has high attack complexity, limiting practical exploitation. IBM has published a support advisory documenting the affected releases and remediation. No public proof-of-concept code has been released, and the vulnerability is not listed in the CISA Known Exploited Vulnerabilities catalog.

Critical Impact

A local authenticated user can exploit an integer overflow in AIX and VIOS to disclose limited sensitive information or crash affected services, degrading system availability on shared enterprise UNIX hosts.

Affected Products

  • IBM AIX 7.2
  • IBM AIX 7.3
  • IBM PowerVM VIOS 4.1

Discovery Timeline

  • 2026-08-19 - CVE-2026-16890 published to NVD
  • 2026-08-20 - Last updated in NVD database

Technical Details for CVE-2026-16890

Vulnerability Analysis

The vulnerability is an integer overflow condition within components shared by IBM AIX 7.2, AIX 7.3, and PowerVM VIOS 4.1. When arithmetic operations on size or length values exceed the maximum value representable by the target integer type, the result wraps around. Subsequent memory operations or resource allocations then proceed with an incorrect size assumption.

Exploitation grants an attacker limited read access to memory contents adjacent to the miscalculated allocation, or forces the affected process to reach an inconsistent state that terminates execution. The confidentiality and availability impact are both rated Low, and integrity is unaffected. High attack complexity indicates the attacker must satisfy specific runtime conditions to reliably trigger the overflow.

Root Cause

The root cause is missing or insufficient validation of integer values used in size, length, or offset calculations. IBM has not published the specific function or code path in the public advisory. The weakness is classified under CWE-190: Integer Overflow or Wraparound.

Attack Vector

Exploitation requires local shell access on an AIX or VIOS system with valid low-privilege credentials. The attacker interacts with the vulnerable component through supported interfaces, supplying crafted numeric inputs that cause the overflow. No user interaction from another party is required, and the impact remains within the affected process scope.

No verified exploit code is publicly available. Refer to the IBM Support Page for authoritative technical details.

Detection Methods for CVE-2026-16890

Indicators of Compromise

  • Unexpected termination or core dumps from AIX or VIOS system processes on affected releases
  • Anomalous local process activity from low-privilege user accounts targeting system utilities
  • Log entries indicating repeated malformed input to affected AIX or VIOS interfaces

Detection Strategies

  • Monitor AIX errpt and VIOS error logs for recurring process crashes tied to specific user sessions
  • Correlate local shell activity with fault events on Power Systems hosts to identify probing behavior
  • Baseline expected system-call and syslog volume, then alert on deviations from low-privilege accounts

Monitoring Recommendations

  • Enable AIX Audit subsystem to capture command execution and file access by non-administrative users
  • Forward AIX and VIOS logs to a central SIEM for retention and cross-host correlation
  • Track authentication events on VIOS partitions to identify unauthorized local access preceding fault activity

How to Mitigate CVE-2026-16890

Immediate Actions Required

  • Inventory all AIX 7.2, AIX 7.3, and PowerVM VIOS 4.1 systems and confirm current patch levels
  • Apply the IBM-provided fix as documented in the vendor advisory at the earliest maintenance window
  • Restrict interactive shell access on affected hosts to the minimum set of required administrative users
  • Review sudo and RBAC configurations to ensure low-privilege accounts cannot reach unnecessary system interfaces

Patch Information

IBM has released fixes for the affected AIX and VIOS versions. Consult the IBM Support Page for the applicable interim fix (iFix) or Service Pack, download instructions, and installation prerequisites for each release.

Workarounds

  • Limit local login access on AIX and VIOS partitions to trusted administrators until patches are applied
  • Enforce least-privilege RBAC roles to reduce the attack surface reachable by standard users
  • Increase audit logging verbosity on affected hosts to detect exploitation attempts during the patch window
bash
# Check current AIX version and installed fixes
oslevel -s
instfix -i | grep -i <APAR-ID>

# On VIOS, verify version as the padmin user
ioslevel

Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.

Default Legacy - Prefooter | Experience the World’s Most Advanced Cybersecurity Platform

Experience the Most Advanced Cybersecurity Platform

See how the world’s most intelligent, autonomous cybersecurity platform can protect your organization today and into the future.