Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.
Sources: National Vulnerability Database, CISA KEV, Exploit-DB
CVE-2026-16164 Overview
CVE-2026-16164 is a buffer overflow vulnerability in IBM DataPower Gateway that allows unauthenticated remote attackers to trigger a denial of service. The flaw affects multiple release trains, including versions 10.5.0.0 through 10.5.0.22, 10.6.1 through 10.6.6, 10.6.0.0 through 10.6.0.10, and 11.0.0.0 through 11.0.0.2. The weakness is classified as an out-of-bounds write [CWE-787]. Because DataPower Gateway functions as a security and integration appliance at the network edge, disruption can interrupt API traffic, message routing, and B2B workloads for downstream services.
Critical Impact
A remote, unauthenticated attacker can cause service disruption of IBM DataPower Gateway appliances, interrupting API traffic and message processing for all dependent applications.
Affected Products
- IBM DataPower Gateway 10.5.0.0 through 10.5.0.22
- IBM DataPower Gateway 10.6.0.0 through 10.6.0.10 and 10.6.1 through 10.6.6
- IBM DataPower Gateway 11.0.0.0 through 11.0.0.2
Discovery Timeline
- 2026-10-08 - CVE-2026-16164 published to NVD
- 2026-10-15 - Last updated in NVD database
Technical Details for CVE-2026-16164
Vulnerability Analysis
The vulnerability is an out-of-bounds write condition in IBM DataPower Gateway. An attacker reaches the flaw over the network without authentication or user interaction. Successful exploitation writes beyond an allocated buffer, corrupting adjacent memory and crashing the affected process. The current attack impact is limited to availability; confidentiality and integrity are not affected based on the published CVSS vector.
IBM DataPower Gateway processes XML, JSON, SOAP, REST, and B2B traffic at the perimeter. A reliable denial of service against the gateway can disrupt API-facing applications, partner integrations, and backend systems that depend on it. The EPSS probability is 0.332% at the 24.894 percentile as of 2026-10-18.
Root Cause
The underlying weakness is classified as [CWE-787] Out-of-bounds Write. A code path handling attacker-controlled input fails to validate length or offset constraints before writing to a fixed-size buffer. IBM has not publicly released detailed root-cause analysis beyond the advisory.
Attack Vector
The attack vector is network-based with low complexity, requires no privileges, and no user interaction. An attacker sends a crafted request to a network-exposed DataPower Gateway listener. The malformed input triggers the overflow and terminates the processing component, producing a denial of service.
No public proof-of-concept exploit is available at the time of publication. Consult the IBM Support Document for vendor-provided technical details.
Detection Methods for CVE-2026-16164
Indicators of Compromise
- Unexpected restarts, crashes, or core dumps of DataPower Gateway processes without a corresponding administrative action.
- Spikes in request processing errors, dropped connections, or latency on gateway listeners.
- Repeated malformed requests from the same source address targeting DataPower endpoints.
Detection Strategies
- Enable DataPower system and audit logging and forward events to a central log pipeline for correlation.
- Compare gateway process uptime against baseline to flag abnormal termination patterns.
- Inspect upstream load balancer and firewall logs for burst traffic preceding gateway failures.
Monitoring Recommendations
- Alert on gateway health probe failures and HTTP 5xx response rate deviations from baseline.
- Monitor process restart counts and memory faults reported by the appliance.
- Track network sources that generate protocol errors or truncated requests against DataPower listeners.
How to Mitigate CVE-2026-16164
Immediate Actions Required
- Inventory all IBM DataPower Gateway instances and identify versions within the affected ranges.
- Apply the fixed releases referenced in the IBM Support Document as soon as change windows allow.
- Restrict network access to DataPower management and data-plane listeners to known client ranges.
- Verify that high-availability pairs are patched in sequence to preserve service continuity.
Patch Information
IBM has published remediation guidance in the vendor advisory. Refer to the IBM Support Document for the fixed version list and firmware upgrade procedures for the 10.5, 10.6, and 11.0 branches.
Workarounds
- Place DataPower Gateway behind a hardened reverse proxy or Web Application Firewall that enforces request size and schema validation.
- Apply strict access control lists on perimeter firewalls to limit who can reach gateway listeners.
- Enable rate limiting and connection throttling on upstream load balancers to reduce impact of flood-style exploitation attempts.
# Example: restrict DataPower listener exposure at the firewall layer
# Allow only trusted client subnets to reach the gateway data plane
iptables -A INPUT -p tcp --dport 443 -s 10.0.0.0/8 -j ACCEPT
iptables -A INPUT -p tcp --dport 443 -j DROP
Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.
Sources: National Vulnerability Database, CISA KEV, Exploit-DB