Skip to main content
Vulnerability Database/CVE-2026-16111

CVE-2026-16111: IBM DataPower Gateway DOS Vulnerability

CVE-2026-16111 is a denial of service vulnerability in IBM DataPower Gateway caused by a type confusion flaw that enables attackers to disrupt services. This post explains its impact, affected versions, and mitigation steps.

Published:

Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.

Sources: National Vulnerability Database, CISA KEV, Exploit-DB

CVE-2026-16111 Overview

CVE-2026-16111 is a type confusion vulnerability in IBM DataPower Gateway that enables remote, unauthenticated attackers to trigger a denial of service condition. The flaw affects versions 10.5.0.0 through 10.5.0.22, 10.6.1 through 10.6.6, 10.6.0.0 through 10.6.0.10, and 11.0.0.0 through 11.0.0.2. An attacker can send crafted network input that causes the gateway to misinterpret data types, resulting in service disruption. The weakness is tracked as CWE-843: Access of Resource Using Incompatible Type.

Critical Impact

Remote unauthenticated attackers can disrupt availability of IBM DataPower Gateway appliances handling API, SOA, and B2B traffic without any user interaction.

Affected Products

  • IBM DataPower Gateway 10.5.0.0 through 10.5.0.22
  • IBM DataPower Gateway 10.6.0.0 through 10.6.0.10 and 10.6.1 through 10.6.6
  • IBM DataPower Gateway 11.0.0.0 through 11.0.0.2

Discovery Timeline

  • 2026-10-08 - CVE-2026-16111 published to NVD
  • 2026-10-15 - Last updated in NVD database

Technical Details for CVE-2026-16111

Vulnerability Analysis

IBM DataPower Gateway operates as a security and integration appliance that processes API, SOAP, REST, and B2B traffic at the network edge. The vulnerability stems from a type confusion flaw where the gateway accesses a resource using an incompatible type. When the processing engine interprets input as one type while it was allocated or structured as another, internal state becomes inconsistent. This inconsistency triggers a fault that terminates processing and interrupts service availability.

The flaw requires no authentication, no privileges, and no user interaction. Because DataPower sits in the request path for critical enterprise integrations, successful exploitation can cascade into broader outages across downstream services.

Root Cause

The root cause is tracked as [CWE-843], where the application accesses a resource using an incompatible type. In type-confusion conditions, a pointer or object reference is treated as a different type than it was originally allocated, violating type-safety assumptions. The resulting memory access produces undefined behavior that the gateway cannot recover from gracefully, leading to termination of the processing path.

Attack Vector

The attack vector is network-based with low complexity. An attacker sends crafted traffic to an exposed DataPower service endpoint. Because DataPower frequently terminates external connections, the attack surface commonly includes internet-facing listeners. No credentials are required to reach the vulnerable code path.

No public proof-of-concept exploit is currently available, and the vulnerability is not listed in the CISA Known Exploited Vulnerabilities catalog. Refer to the IBM Support advisory for vendor-provided technical details.

Detection Methods for CVE-2026-16111

Indicators of Compromise

  • Unexpected restarts or crash logs from DataPower processing threads coinciding with inbound traffic spikes
  • Service unavailability events on DataPower listeners without corresponding backend failures
  • Malformed or anomalous requests originating from untrusted sources targeting DataPower endpoints

Detection Strategies

  • Monitor DataPower system logs for abnormal termination events, segmentation faults, and processing-engine restarts
  • Correlate availability drops on DataPower virtual services with inbound request patterns from single sources
  • Baseline normal API request structures and alert on protocol anomalies that deviate from expected schemas

Monitoring Recommendations

  • Forward DataPower audit and system logs to a centralized SIEM for continuous analysis
  • Enable health checks and uptime monitoring on all DataPower services with alerting on repeated failures
  • Track request-rate anomalies and connection resets at the network perimeter in front of DataPower

How to Mitigate CVE-2026-16111

Immediate Actions Required

  • Inventory all IBM DataPower Gateway instances and identify versions within the affected ranges
  • Apply the fixed firmware release referenced in the IBM Support advisory as soon as change windows permit
  • Restrict network exposure of DataPower management and service interfaces to trusted sources where possible

Patch Information

IBM has published remediation guidance at the IBM Support page for this issue. Administrators should upgrade to the fixed release level corresponding to their deployed branch (10.5, 10.6, or 11.0) as specified in the advisory.

Workarounds

  • Place a hardened upstream filter, such as a web application firewall, in front of DataPower to drop malformed requests
  • Rate-limit inbound connections from untrusted networks to reduce the impact of repeated DoS attempts
  • Segment DataPower management interfaces onto restricted administrative networks until patches are applied
bash
# Example: restrict DataPower service exposure at the perimeter firewall
# Allow only known partner ranges to reach the DataPower listener
iptables -A INPUT -p tcp --dport 443 -s 203.0.113.0/24 -j ACCEPT
iptables -A INPUT -p tcp --dport 443 -j DROP

Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.

Sources: National Vulnerability Database, CISA KEV, Exploit-DB

Experience the Most Advanced Cybersecurity Platform

See how the world’s most intelligent, autonomous cybersecurity platform can protect your organization today and into the future.