Skip to main content
CVE Vulnerability Database
Vulnerability Database/CVE-2026-15203

CVE-2026-15203: Danfoss iC7 Privilege Escalation Vulnerability

CVE-2026-15203 is a privilege escalation vulnerability in Danfoss iC7-Automation SP, iC7-Marine, and iC7-Hybrid GR3 that allows attackers to upload unsigned code and modify firmware. This post covers technical details, affected versions, impact, and mitigation steps.

Published:

CVE-2026-15203 Overview

CVE-2026-15203 is an improper access control vulnerability [CWE-1191] affecting Danfoss iC7-Automation SP, iC7-Marine, and iC7-Hybrid GR3 industrial drives. Exposed debug and engineering interfaces allow unauthenticated network attackers to read and write internal values, upload and execute unsigned applications, and push unsigned EEPROM data and firmware through the service interfaces and software update mechanisms. The flaw compromises the integrity of the drive firmware and its runtime configuration. Danfoss has published updated software packages to address the issue.

Critical Impact

Unauthenticated attackers on the network can execute unsigned code and replace firmware on affected industrial drives, undermining safety-critical operations.

Affected Products

  • Danfoss iC7-Automation SP
  • Danfoss iC7-Marine
  • Danfoss iC7-Hybrid GR3

Discovery Timeline

  • 2026-08-26 - CVE-2026-15203 published to the National Vulnerability Database (NVD)
  • 2026-08-26 - Last updated in NVD database

Technical Details for CVE-2026-15203

Vulnerability Analysis

The vulnerability sits in the debug and engineering interfaces exposed by the affected iC7 drives. These service endpoints permit read and write access to internal device values without adequate authentication or authorization checks. Attackers with network reachability can query and modify runtime parameters that control drive behavior.

Beyond parameter manipulation, the software update path accepts unsigned payloads. An attacker can upload unsigned applications, EEPROM data, or full firmware images and execute them on the device. This gives the attacker persistent, low-level control over the drive.

Because iC7 drives operate in automation, marine propulsion, and hybrid power systems, tampering with firmware or configuration values can affect physical processes. The exposed interfaces bypass the normal engineering workstation trust boundary.

Root Cause

The root cause is a design-level exposure of privileged debug and engineering functionality [CWE-1191]. The service interfaces lack authentication controls, and the software update mechanism does not enforce cryptographic signature verification on uploaded applications, EEPROM data, or firmware images.

Attack Vector

The attack vector is network-based and requires no privileges or user interaction. An attacker with connectivity to the drive's service interface can invoke debug commands, write internal values, and deliver unsigned code through the update channel. Successful exploitation yields full read, write, and code execution capabilities on the drive.

No verified public exploit code is available. Refer to the Danfoss software packages linked in the NVD entry for CVE-2026-15203 for the corrected firmware.

Detection Methods for CVE-2026-15203

Indicators of Compromise

  • Unexpected firmware version strings or build identifiers reported by iC7 drives during routine polling.
  • Unscheduled software update events or EEPROM write operations recorded in engineering tool logs.
  • Network sessions to iC7 service and engineering ports originating from hosts outside the sanctioned engineering workstation set.

Detection Strategies

  • Baseline the firmware hash and configuration parameter set of each iC7 drive and alert on drift.
  • Inspect operational technology (OT) network traffic for engineering protocol commands directed at drives from non-engineering assets.
  • Correlate physical process anomalies with recent parameter writes or update events on the drive.

Monitoring Recommendations

  • Enable syslog or event forwarding from engineering tools and drive controllers into a central log store for retention and search.
  • Monitor ingress and egress at the OT/IT boundary for connections targeting Danfoss iC7 service interfaces.
  • Review change management records against observed firmware and EEPROM update events to identify unauthorized activity.

How to Mitigate CVE-2026-15203

Immediate Actions Required

  • Inventory all Danfoss iC7-Automation SP, iC7-Marine, and iC7-Hybrid GR3 devices and record their current firmware versions.
  • Restrict network access to drive service and engineering interfaces to a small set of authorized engineering workstations.
  • Apply the updated software packages published by Danfoss to every affected drive.

Patch Information

Danfoss has published corrected software packages for the affected iC7 product lines. Download the vendor-provided packages from Danfoss Software Package ID543724747716, Danfoss Software Package ID506542766960, and Danfoss Software Package ID506543688961. Validate package integrity against vendor-published hashes before deployment.

Workarounds

  • Segment iC7 drives onto a dedicated OT VLAN and block routed access from corporate networks and the internet.
  • Enforce firewall rules that allow only known engineering workstation IP addresses to reach drive service ports.
  • Disable or physically disconnect service interfaces on drives that do not require active engineering access.
  • Require jump-host access with session recording for any engineering workstation permitted to reach the drives.

Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.

Default Legacy - Prefooter | Experience the World’s Most Advanced Cybersecurity Platform

Experience the Most Advanced Cybersecurity Platform

See how the world’s most intelligent, autonomous cybersecurity platform can protect your organization today and into the future.