Skip to main content
Vulnerability Database/CVE-2026-14507

CVE-2026-14507: IBM DataPower Gateway DOS Vulnerability

CVE-2026-14507 is a denial of service vulnerability in IBM DataPower Gateway caused by improper memory allocation during key derivation. This article covers the technical details, affected versions, and mitigation strategies.

Published:

Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.

Sources: National Vulnerability Database, CISA KEV, Exploit-DB

CVE-2026-14507 Overview

CVE-2026-14507 affects IBM DataPower Gateway versions 11.0.0.0 through 11.0.0.2. A remote authenticated attacker can trigger a denial-of-service condition through improper memory allocation during key derivation. The flaw is tracked under CWE-787 (Out-of-Bounds Write) and originates in the cryptographic key derivation path.

IBM published the advisory on its support portal. Because DataPower Gateway often sits at the edge of enterprise API and integration traffic, a successful attack can disrupt service availability for downstream applications.

Critical Impact

An authenticated attacker on the network can crash or exhaust the DataPower Gateway, interrupting API, SOA, and B2B traffic that depends on the appliance.

Affected Products

  • IBM DataPower Gateway 11.0.0.0
  • IBM DataPower Gateway 11.0.0.1
  • IBM DataPower Gateway 11.0.0.2

Discovery Timeline

  • 2026-10-08 - CVE-2026-14507 published to NVD
  • 2026-10-14 - Last updated in NVD database

Technical Details for CVE-2026-14507

Vulnerability Analysis

The vulnerability resides in the key derivation routine used by IBM DataPower Gateway. During derivation, the component allocates memory incorrectly, which permits an out-of-bounds write condition. The resulting corruption terminates the affected process and halts request handling on the gateway.

Exploitation requires valid authentication to the gateway and network reachability to the management or data plane. No user interaction is needed. The attack affects availability only; confidentiality and integrity are not impacted according to the CVSS vector. The scope is marked as changed, indicating the fault can affect components beyond the originally vulnerable one.

Root Cause

The root cause is improper memory allocation during cryptographic key derivation, categorized as [CWE-787] Out-of-Bounds Write. When the derivation function processes certain inputs, it writes outside the bounds of the allocated buffer. This corrupts adjacent memory and crashes the handling process.

Attack Vector

An attacker with valid credentials sends a crafted request that invokes the vulnerable key derivation code path. The malformed input triggers the out-of-bounds write, causing the gateway worker or service to terminate. Repeated requests sustain the denial-of-service condition and prevent legitimate traffic from being processed.

No public proof-of-concept exploit is available, and the vulnerability is not listed in the CISA Known Exploited Vulnerabilities catalog. See the IBM Security Advisory for vendor-supplied technical context.

Detection Methods for CVE-2026-14507

Indicators of Compromise

  • Unexpected restarts or crash dumps on DataPower Gateway processes handling cryptographic operations.
  • Spikes in authenticated API requests invoking key derivation functions from unusual source identities.
  • Error log entries referencing memory allocation failures during TLS or key derivation operations.

Detection Strategies

  • Correlate authentication logs with gateway process crashes to identify sessions that preceded service disruption.
  • Alert on repeated service restarts or health-check failures on DataPower appliances running versions 11.0.0.0 through 11.0.0.2.
  • Review audit trails for authenticated users issuing malformed cryptographic requests outside normal usage patterns.

Monitoring Recommendations

  • Ingest DataPower system and audit logs into a centralized logging or SIEM platform for crash and anomaly correlation.
  • Monitor appliance CPU, memory, and process uptime metrics to detect degradation patterns consistent with repeated DoS attempts.
  • Track administrative and API client authentication events for abnormal source addresses or credential reuse.

How to Mitigate CVE-2026-14507

Immediate Actions Required

  • Inventory all IBM DataPower Gateway appliances and identify instances running versions 11.0.0.0 through 11.0.0.2.
  • Apply the fix referenced in the IBM Security Advisory as soon as it is available in your change window.
  • Restrict management and API access to trusted networks and enforce least-privilege authentication for gateway users.

Patch Information

IBM has published guidance for CVE-2026-14507 at the IBM Security Advisory. Administrators should consult the advisory for the specific fix pack or iFix that remediates the key derivation defect in DataPower Gateway 11.0.0.x and plan an upgrade accordingly.

Workarounds

  • Limit the set of authenticated users and service accounts that can reach cryptographic endpoints on the gateway.
  • Place DataPower management interfaces behind network segmentation and VPN-only access to reduce exposure.
  • Enable rate limiting and anomaly detection on API traffic to slow repeated exploitation attempts while patching is scheduled.
bash
# Example: restrict management access using an access control list
# Replace with your appliance-specific configuration syntax
acl mgmt-access
  permit 10.0.0.0/24
  deny   0.0.0.0/0

Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.

Sources: National Vulnerability Database, CISA KEV, Exploit-DB

Experience the Most Advanced Cybersecurity Platform

See how the world’s most intelligent, autonomous cybersecurity platform can protect your organization today and into the future.