Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.
Sources: National Vulnerability Database, CISA KEV, Exploit-DB
CVE-2026-111855 Overview
CVE-2026-111855 is a path traversal vulnerability [CWE-22] affecting Tektronix 3 Series MDO oscilloscopes running firmware prior to version 1.21.1. The flaw resides in the device's web management interface, which fails to properly validate user-supplied file paths. Remote attackers can read arbitrary files accessible to the web application process. Depending on device configuration, exploitation may not require authentication, allowing network-based attackers to retrieve sensitive files directly.
Critical Impact
Unauthenticated remote attackers can read arbitrary files from affected Tektronix 3 Series MDO oscilloscopes over the network, exposing configuration data, credentials, and measurement artifacts stored on the device.
Affected Products
- Tektronix 3 Series MDO oscilloscopes with firmware before 1.21.1
- Devices exposing the web management interface on the network
- Deployments where the interface is reachable without authentication
Discovery Timeline
- 2026-10-17 - CVE-2026-111855 published to the National Vulnerability Database
- 2026-10-21 - Last updated in NVD database
Technical Details for CVE-2026-111855
Vulnerability Analysis
The vulnerability stems from insufficient validation of file path parameters processed by the oscilloscope's embedded web management interface. The interface accepts user-supplied input intended to reference files within a bounded directory. Because the input is not canonicalized or restricted, attackers can supply traversal sequences such as ../ to escape the intended directory. The web application then reads files outside the intended root and returns their contents in the HTTP response.
The attack is remotely exploitable over the network with low complexity. In configurations where the web interface is exposed without authentication, no credentials are required. Successful exploitation discloses the contents of any file readable by the service account running the web interface, including device configuration, logs, saved waveform data, and potentially credential material.
Root Cause
The root cause is improper limitation of a pathname to a restricted directory [CWE-22]. The web management interface concatenates attacker-controlled path components with a base directory without rejecting or neutralizing traversal metacharacters. No canonical path check is performed after resolution to confirm the final path remains within the allowed root.
Attack Vector
An attacker with network access to the device sends a crafted HTTP request to a file-handling endpoint of the web interface. The request includes relative path traversal sequences in a parameter that the application uses to construct a filesystem path. The server resolves the path, opens the arbitrary file, and returns its contents. Because the vulnerability only affects confidentiality, integrity and availability of the device are not directly impacted by this specific flaw.
See the Tektronix Product Security Advisory for vendor-provided technical details.
Detection Methods for CVE-2026-111855
Indicators of Compromise
- HTTP requests to the device's web management interface containing ../, ..\, URL-encoded (%2e%2e%2f), or double-encoded traversal sequences in query or path parameters.
- Unexpected outbound retrieval of files such as /etc/passwd, /etc/shadow, device configuration files, or firmware images from the oscilloscope.
- Access log entries referencing file-serving endpoints from unknown or external source IP addresses.
Detection Strategies
- Inspect network traffic to and from oscilloscopes for HTTP requests containing path traversal patterns, including common encodings.
- Compare observed access patterns against a baseline of normal management activity for lab and OT equipment.
- Correlate HTTP 200 responses from file-handling endpoints with the size and content profile of expected responses to flag anomalies.
Monitoring Recommendations
- Enable and forward web interface access logs from Tektronix 3 Series MDO devices to a central log platform for analysis.
- Alert on any access to the oscilloscope's web management interface from outside the designated OT management subnet.
- Monitor for repeated 4xx or 5xx responses on file endpoints, which may indicate traversal probing.
How to Mitigate CVE-2026-111855
Immediate Actions Required
- Upgrade affected Tektronix 3 Series MDO devices to firmware version 1.21.1 or later as described in the vendor advisory.
- Remove the device's web management interface from any network segment reachable by untrusted hosts.
- Enforce authentication on the web interface where configuration permits and rotate any credentials potentially exposed by file disclosure.
Patch Information
Tektronix addresses the vulnerability in firmware version 1.21.1. Refer to the Tektronix Product Security Advisory for official patch availability and installation guidance. Product information for the affected hardware is available on the Tektronix 3 Series MDO Oscilloscope product page.
Workarounds
- Place affected oscilloscopes on an isolated management VLAN with strict access control lists limiting access to authorized engineering workstations.
- Block inbound HTTP and HTTPS traffic to the device at the perimeter firewall until firmware 1.21.1 is deployed.
- Disable the web management interface on devices where it is not required for operational use.
Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.