Skip to main content
Vulnerability Database/CVE-2026-108796

CVE-2026-108796: ZKTeco BioTime Authentication Bypass

CVE-2026-108796 is an authentication bypass vulnerability in ZKTeco BioTime 9.5.6 affecting the biometric data endpoint. Attackers can manipulate emp_code to bypass authorization remotely. This article covers technical details, affected versions, impact assessment, and mitigation strategies.

Published:

Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.

Sources: National Vulnerability Database, CISA KEV, Exploit-DB

CVE-2026-108796 Overview

CVE-2026-108796 is an authorization bypass vulnerability in ZKTeco BioTime 9.5.6 Build 20260130.3206. The flaw resides in the /iclock/finger_data/ path of the Biometric Data Endpoint component. Attackers manipulate the emp_code argument to bypass authorization controls and access biometric data belonging to other employees. The issue is exploitable remotely over the network and requires low-privilege authenticated access. ZKTeco addressed the issue in BioTime 9.5.6 Build 3623. The vulnerability is categorized under [CWE-285: Improper Authorization].

Critical Impact

Authenticated remote attackers can bypass authorization checks on the biometric data endpoint and access records associated with other employees by manipulating the emp_code parameter.

Affected Products

  • ZKTeco BioTime 9.5.6 Build 20260130.3206
  • Component: Biometric Data Endpoint (/iclock/finger_data/)
  • Fixed in: ZKTeco BioTime 9.5.6 Build 3623

Discovery Timeline

  • 2026-10-12 - CVE-2026-108796 published to NVD
  • 2026-10-16 - Last updated in NVD database

Technical Details for CVE-2026-108796

Vulnerability Analysis

ZKTeco BioTime is a workforce management platform that handles biometric authentication data such as fingerprint templates. The /iclock/finger_data/ endpoint exposes biometric records tied to employees. The application fails to verify whether the authenticated caller is authorized to access the record identified by the emp_code argument. An attacker who can authenticate with low privileges can supply arbitrary emp_code values to retrieve biometric data belonging to other employees.

The weakness falls under [CWE-285: Improper Authorization]. The server performs the requested action based on the supplied identifier without enforcing a per-record access decision. This is a classic Insecure Direct Object Reference pattern on a sensitive biometric data endpoint.

Root Cause

The root cause is missing per-object authorization checks in the handler for /iclock/finger_data/. The application trusts the emp_code parameter supplied by the client and returns data without validating that the authenticated session owns or has rights to that employee record.

Attack Vector

Exploitation is remote over the network and requires low privileges. The attacker sends crafted HTTP requests to /iclock/finger_data/ while iterating emp_code values. No user interaction is required. Impact is limited to confidentiality of biometric data; integrity and availability are not directly affected based on the published scoring.

No verified public exploit code is available at the time of writing. Technical details are documented in the VulDB entry for CVE-2026-108796 and the ZKTeco Security Bulletin #27.

Detect Identity Attacks the Moment Authentication Fails

Singularity™ Identity surfaces credential misuse, lateral movement, and privilege escalation in real time, so you can contain the breach before it spreads.

Stop Identity Attacks

Detection Methods for CVE-2026-108796

Indicators of Compromise

  • Repeated HTTP requests to /iclock/finger_data/ with sequentially changing emp_code values from a single session or source IP.
  • Access to biometric records by user accounts that do not administratively own those records.
  • Unusual volume of successful responses from the /iclock/finger_data/ endpoint outside normal timekeeping workflows.

Detection Strategies

  • Enable verbose request logging on the BioTime web server and alert on enumeration patterns against /iclock/finger_data/.
  • Correlate authenticated session identifiers with the emp_code values they request and flag mismatches.
  • Deploy web application firewall rules to rate-limit and inspect requests to the Biometric Data Endpoint.

Monitoring Recommendations

  • Monitor outbound data volume from BioTime servers for anomalies consistent with bulk biometric data extraction.
  • Track authentication logs for low-privilege accounts generating high request volumes against /iclock/.
  • Review access to biometric templates through BioTime audit trails on a scheduled cadence.

How to Mitigate CVE-2026-108796

Immediate Actions Required

  • Upgrade ZKTeco BioTime to version 9.5.6 Build 3623 or later as specified in the ZKTeco Security Bulletin #27.
  • Restrict network exposure of the BioTime management interface to trusted administrative networks only.
  • Rotate and audit credentials for low-privilege accounts that could be abused to reach the endpoint.

Patch Information

ZKTeco resolved the authorization bypass in BioTime 9.5.6 Build 3623. Administrators should apply the vendor patch as documented in the vendor advisory. Review the VulDB record for additional technical context before planning the upgrade.

Workarounds

  • Place BioTime behind a reverse proxy or VPN and block direct Internet exposure of /iclock/finger_data/.
  • Apply web application firewall rules that validate the authenticated session has rights to the requested emp_code where feasible.
  • Disable or restrict low-privilege accounts that are not required for daily operation until the patch is applied.
bash
# Example: block external access to the vulnerable endpoint at the reverse proxy
# nginx snippet
location /iclock/finger_data/ {
    allow 10.0.0.0/8;        # internal admin range
    deny all;
    proxy_pass http://biotime_backend;
}

Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.