CVE-2026-107186 Overview

CVE-2026-107186 is an authentication bypass vulnerability [CWE-287] affecting Eptura Archibus. An unauthenticated attacker can send a Direct Web Remoting (DWR) request that chains isPasswordUppercase as one call method with a subsequent call method set to execute a workflow rule. This chaining allows workflow rules to run without authentication, bypassing access controls on the application.

The vulnerability is reachable over the network, requires no privileges, and no user interaction. Rapid7 researchers disclosed the issue as part of a broader set of Eptura Archibus findings that also include remote code execution and database read vulnerabilities.

Critical Impact

Unauthenticated remote attackers can invoke arbitrary workflow rules, enabling access to privileged application logic without valid credentials.

Affected Products

  • Eptura Archibus (versions prior to the fixed release)
  • Deployments exposing the DWR endpoint to untrusted networks
  • Any Archibus instance where workflow rules carry sensitive operations

Discovery Timeline

  • 2026-10-19 - CVE-2026-107186 published to the National Vulnerability Database
  • 2026-10-20 - Last updated in NVD database

Technical Details for CVE-2026-107186

Vulnerability Analysis

The flaw resides in how the Archibus DWR endpoint validates authentication state across chained call methods within a single request. DWR allows clients to invoke multiple server-side Java methods in one HTTP request. The server treats isPasswordUppercase as a method that does not require authentication, since it is used during the login flow to help clients normalize credentials.

When an attacker includes isPasswordUppercase as the first call in the batch, the request passes the pre-authentication gate. Subsequent calls in the same batch inherit that unauthenticated context but are still dispatched to privileged handlers, including the workflow rule execution endpoint. The server executes the second call without re-validating the session.

Workflow rules in Archibus expose business logic that is intended to be invoked only by authenticated and authorized users. Bypassing authentication on this entry point exposes application internals and can be chained with other Archibus vulnerabilities disclosed by Rapid7 to achieve remote code execution and database read access.

Root Cause

The root cause is improper authentication [CWE-287] in the DWR request dispatcher. The dispatcher applies the authentication check to the first method in a batched call rather than to each method individually. This design assumption breaks when a batch mixes a public method with a privileged one.

Attack Vector

An attacker sends a crafted HTTP POST to the Archibus DWR endpoint. The request body contains two call entries: isPasswordUppercase followed by a call that targets the workflow rule execution method with attacker-controlled parameters. No credentials, cookies, or session tokens are required. The attack is scriptable and can be repeated at scale against internet-exposed Archibus instances. See the Rapid7 Blog on Eptura Archibus Fix for additional context.

Detect Identity Attacks the Moment Authentication Fails

Singularity™ Identity surfaces credential misuse, lateral movement, and privilege escalation in real time, so you can contain the breach before it spreads.

Stop Identity Attacks

Detection Methods for CVE-2026-107186

Indicators of Compromise

  • Unauthenticated POST requests to DWR endpoints that reference isPasswordUppercase alongside additional call entries in the same body.
  • Workflow rule execution events in Archibus application logs with no preceding authenticated session identifier.
  • Anomalous outbound connections or database queries originating from the Archibus application process shortly after DWR traffic.

Detection Strategies

  • Parse Archibus web server logs for DWR batch requests containing more than one callCount entry where the first call references isPasswordUppercase.
  • Alert on workflow rule invocations by sessions that lack a prior successful authentication event.
  • Correlate web request logs with application audit logs to identify workflow executions attributed to anonymous or empty user contexts.

Monitoring Recommendations

  • Enable verbose logging on the Archibus DWR endpoint and forward logs to a centralized analytics platform.
  • Monitor for spikes in DWR traffic volume or sudden increases in workflow rule execution rates.
  • Baseline normal DWR method usage and alert on deviations, especially public methods appearing in multi-call batches.

How to Mitigate CVE-2026-107186

Immediate Actions Required

  • Upgrade Eptura Archibus to the vendor-provided fixed release referenced in the Rapid7 Blog on Eptura Archibus Fix.
  • Restrict network access to the Archibus application so the DWR endpoint is not reachable from the public internet.
  • Review Archibus audit logs for prior unauthorized workflow rule executions and investigate any anomalies.

Patch Information

Eptura has released a security update for Archibus that addresses the DWR authentication bypass alongside additional remote code execution and database read vulnerabilities. Administrators should apply the vendor patch and confirm the fixed build is deployed on all Archibus application servers. Consult vendor advisories and the Rapid7 writeup for exact version numbers and upgrade guidance.

Workarounds

  • Place the Archibus application behind a web application firewall (WAF) and block DWR requests that contain isPasswordUppercase combined with additional call entries.
  • Enforce IP allowlisting or VPN-only access to the Archibus web interface until the patch is applied.
  • Disable or restrict workflow rule execution endpoints at the reverse proxy layer where feasible.