Skip to main content
Vulnerability Database/CVE-2026-105706

CVE-2026-105706: Drug Recommendation System CSRF Vulnerability

CVE-2026-105706 is a cross-site request forgery flaw in SourceCodester Drug Recommendation System 1.0 that enables attackers to perform unauthorized actions. This article covers technical details, affected versions, and mitigation.

Published:

Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.

Sources: National Vulnerability Database, CISA KEV, Exploit-DB

CVE-2026-105706 Overview

CVE-2026-105706 is a Cross-Site Request Forgery (CSRF) vulnerability [CWE-352] in SourceCodester Drug Recommendation System 1.0. The affected application does not implement anti-CSRF tokens on state-changing requests. Attackers can trick authenticated users into submitting forged requests from a remote origin. A public exploit is available, but no in-the-wild exploitation has been reported.

Critical Impact

An attacker can coerce an authenticated user's browser to perform unintended state-changing actions in the Drug Recommendation System, potentially modifying application data without the user's knowledge.

Affected Products

  • SourceCodester Drug Recommendation System 1.0

Discovery Timeline

  • 2026-10-06 - CVE-2026-105706 published to the National Vulnerability Database (NVD)
  • 2026-10-06 - Last updated in NVD database

Technical Details for CVE-2026-105706

Vulnerability Analysis

The Drug Recommendation System 1.0 exposes web functionality that performs state changes without validating request origin. Because the application does not issue or verify anti-CSRF tokens, the browser's standard same-site cookie handling is the only barrier between an attacker-controlled page and an authenticated session. An attacker hosting a malicious page can submit forged HTTP requests that the victim's browser executes with the victim's session cookies attached.

The attack requires an authenticated victim to visit attacker-controlled content or interact with a crafted link. Exploitation is remote and does not require attacker-side authentication. The impact is bounded to integrity changes within the application; confidentiality and availability are not directly affected based on the published scoring.

Root Cause

The root cause is the absence of CSRF protection on sensitive endpoints. The application fails to generate per-session or per-request synchronizer tokens, and it does not verify an Origin or Referer header before processing state-changing operations.

Attack Vector

Exploitation requires network reachability to the victim and user interaction, such as the victim clicking a link or loading a page that contains a crafted HTML form or image tag. The forged request inherits the victim's authenticated session. Technical details are documented in the GitHub CSRF Vulnerability Report and the VulDB entry for CVE-2026-105706.

Detection Methods for CVE-2026-105706

Indicators of Compromise

  • Unexpected state-changing HTTP POST requests to the Drug Recommendation System originating from external Referer headers.
  • Application records showing data modifications that users do not recognize or did not initiate.
  • Clusters of similar POST requests from distinct user sessions within a short time window following access to external links.

Detection Strategies

  • Inspect web server access logs for POST requests whose Referer or Origin header points to a domain outside the application.
  • Correlate browser referrer data with user-reported anomalies in recommendation or account data.
  • Deploy a Web Application Firewall (WAF) rule that flags state-changing requests missing a valid Origin header matching the application host.

Monitoring Recommendations

  • Enable verbose HTTP request logging on the application server, including request headers and parameters.
  • Alert on repeated POST submissions from the same session that originate from different Referer values within a short interval.
  • Monitor authentication and session management events to identify sessions acting outside typical workflows.

How to Mitigate CVE-2026-105706

Immediate Actions Required

  • Restrict access to the Drug Recommendation System to trusted networks until a patched version is applied.
  • Instruct authenticated users to log out of the application before browsing external sites.
  • Configure session cookies with the SameSite=Strict attribute to limit cross-site cookie attachment.

Patch Information

At the time of publication, no vendor patch is listed in the NVD record for CVE-2026-105706. Monitor SourceCodester for an updated release of Drug Recommendation System and review the VulDB vulnerability entry #413699 for remediation updates.

Workarounds

  • Implement synchronizer token pattern on all state-changing endpoints by generating a per-session token and validating it server-side.
  • Validate the Origin and Referer headers on every state-changing request and reject mismatches.
  • Set the session cookie attributes to SameSite=Strict; Secure; HttpOnly to reduce cross-origin request risk.
  • Require re-authentication or step-up verification for sensitive operations such as account changes.
bash
# Example: Apache mod_headers configuration to enforce SameSite on session cookies
Header edit Set-Cookie ^(PHPSESSID=.*)$ "$1; SameSite=Strict; Secure; HttpOnly"

Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.

Sources: National Vulnerability Database, CISA KEV, Exploit-DB

Experience the Most Advanced Cybersecurity Platform

See how the world’s most intelligent, autonomous cybersecurity platform can protect your organization today and into the future.