CVE-2026-105667: HL7 Listener Auth Bypass Vulnerability

CVE-2026-105667 is an authentication bypass flaw in HL7 listeners that allows unauthenticated patient-merge messages, enabling attackers to reassign patient studies. This post explains its impact, technical details, and mitigation.

Published:

Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.

Sources: National Vulnerability Database, CISA KEV, Exploit-DB

CVE-2026-105667 Overview

CVE-2026-105667 affects a medical imaging archive's Health Level 7 (HL7) listener that accepts ADT^A40 patient-merge messages in its default configuration. The listener does not authenticate the sending application. A remote attacker can send crafted merge messages to reassign studies and related workflow records from one patient identity to another. The archive's unmerge operation does not reverse the change, making the integrity impact persistent. CISA tracks the issue in Medical Advisory ICSMA-26-288-02. The weakness is categorized under [CWE-306: Missing Authentication for Critical Function].

Critical Impact

An unauthenticated network attacker can permanently reassign patient studies and workflow records, corrupting clinical records with no automated recovery path.

Affected Products

  • Medical imaging archive HL7 listener (see CISA Medical Advisory ICSMA-26-288-02)
  • Deployments running the default HL7 listener configuration
  • Systems processing ADT^A40 patient-merge messages without sender authentication

Discovery Timeline

  • 2026-10-16 - CVE-2026-105667 published to the National Vulnerability Database (NVD)
  • 2026-10-16 - Last updated in NVD database

Technical Details for CVE-2026-105667

Vulnerability Analysis

The affected archive exposes an HL7 listener on the network to receive Admit, Discharge, Transfer (ADT) messages. The ADT^A40 message type instructs the receiving system to merge two patient identities, consolidating studies and workflow records from a source patient identifier into a target patient identifier.

In the default configuration, the listener processes these messages without verifying the identity of the sending application. Any host that can reach the HL7 TCP port can submit a merge request. The archive honors the request as if it originated from a trusted hospital information system.

The integrity impact is amplified by the archive's merge semantics. The vendor's unmerge function does not reverse an ADT^A40 operation performed through the listener. Reassigned studies remain attached to the attacker-chosen patient identity, requiring manual reconciliation of clinical data.

Root Cause

The root cause is missing authentication for a critical function [CWE-306]. The HL7 listener does not require or validate credentials, mutual Transport Layer Security (TLS), network-level allowlisting, or application-level identifiers for inbound ADT^A40 messages. The protocol handler trusts any syntactically valid HL7 message delivered to its listening socket.

Attack Vector

The attack vector is network-based and requires no privileges or user interaction. An attacker reaches the HL7 TCP port, opens a Minimum Lower Layer Protocol (MLLP) framed connection, and transmits an ADT^A40 message specifying arbitrary source and target patient identifiers. The archive processes the merge and persistently reassigns studies. Because the unmerge path does not reverse the operation, the attacker achieves durable record manipulation from a single unauthenticated message.

No verified public exploit code is available at the time of publication. Technical details are described in prose per the CISA advisory; see CISA Medical Advisory ICSMA-26-288-02 and the GitHub CSAF Document for the structured advisory.

Detect Identity Attacks the Moment Authentication Fails

Singularity™ Identity surfaces credential misuse, lateral movement, and privilege escalation in real time, so you can contain the breach before it spreads.

Stop Identity Attacks

Detection Methods for CVE-2026-105667

Indicators of Compromise

  • Inbound MLLP/HL7 connections to the archive from hosts outside the approved hospital information system allowlist.
  • ADT^A40 messages originating from unexpected sending application (MSH-3) or sending facility (MSH-4) values.
  • Unexpected changes in patient-study associations or workflow records with no corresponding clinician action in the audit log.
  • Failed unmerge attempts following suspicious ADT^A40 activity.

Detection Strategies

  • Enable HL7 message auditing on the archive and log every received ADT^A40 with full MSH header fields and source IP.
  • Alert on ADT^A40 messages where MSH-3/MSH-4 does not match the authorized sending systems.
  • Correlate HL7 listener logs with network flow data to flag merges initiated from unapproved network segments.

Monitoring Recommendations

  • Monitor TCP connections to the HL7 listener port and alert on sources outside the clinical VLAN or VPN.
  • Baseline the daily volume of patient-merge operations and alert on statistical deviations.
  • Forward HL7 and network telemetry to a centralized Security Information and Event Management (SIEM) platform for retention and correlation.

How to Mitigate CVE-2026-105667

Immediate Actions Required

  • Restrict network access to the HL7 listener using firewall rules so only authorized hospital information systems can reach the MLLP port.
  • Place the archive on an isolated clinical network segment and block the HL7 port from general enterprise and internet-facing networks.
  • Review archive logs for unexpected ADT^A40 messages received since deployment and reconcile any suspicious merges with clinical staff.
  • Document a manual rollback procedure since the built-in unmerge does not reverse this operation.

Patch Information

No vendor patch is listed in the NVD entry at the time of publication. Refer to CISA Medical Advisory ICSMA-26-288-02 for vendor remediation status and configuration guidance. Apply vendor-provided updates and configuration changes as soon as they are published.

Workarounds

  • Configure the HL7 listener to require authenticated or allowlisted sending applications where the product supports it.
  • Terminate HL7 traffic through a healthcare integration engine that enforces mutual TLS and sender validation before forwarding to the archive.
  • Disable automated processing of ADT^A40 messages and require manual review of merge requests when technically supported.
  • Deploy network access control lists restricting inbound MLLP connections to known hospital information system source IPs.