Skip to main content
Vulnerability Database/CVE-2026-104629

CVE-2026-104629: openPDC/openHistorian RCE Vulnerability

CVE-2026-104629 is a remote code execution flaw in openPDC and openHistorian that allows authenticated attackers to execute arbitrary code through malicious component loading. This post explains its impact, affected versions, and mitigation steps.

Published:

Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.

Sources: National Vulnerability Database, CISA KEV, Exploit-DB

CVE-2026-104629 Overview

CVE-2026-104629 is an unsafe reflection vulnerability [CWE-470] affecting openPDC and openHistorian. A component loading mechanism in these industrial control system (ICS) applications constructs and runs any specified type, including attacker-controlled components placed on the host filesystem. An authenticated user who can write a file to the host can trigger the service to instantiate that type, executing arbitrary constructor code with the privileges of the affected service account. The vulnerability was published to the National Vulnerability Database (NVD) on October 9, 2026, and documented in CISA ICS Advisory ICSA-26-281-02.

Critical Impact

Authenticated attackers with filesystem write access can achieve arbitrary code execution under the service account, compromising confidentiality, integrity, and availability of ICS data acquisition and historian services.

Affected Products

  • openPDC (Phasor Data Concentrator)
  • openHistorian
  • Grid Protection Alliance ICS components using the vulnerable loader

Discovery Timeline

  • 2026-10-09 - CVE-2026-104629 published to NVD
  • 2026-10-09 - Last updated in NVD database

Technical Details for CVE-2026-104629

Vulnerability Analysis

The flaw is categorized as Use of Externally-Controlled Input to Select Classes or Code (Unsafe Reflection) under [CWE-470]. openPDC and openHistorian include a dynamic component loader that accepts a type specification and instantiates the corresponding .NET type at runtime. The loader does not restrict which assemblies or types can be constructed, nor does it validate that the target is a legitimate component.

When the loader instantiates an attacker-chosen type, the type's constructor executes within the service process. Because openPDC and openHistorian typically run as privileged Windows services in operational technology (OT) environments, the attacker inherits those service-account privileges. This exposes grid monitoring data and historian archives to tampering or destruction.

Root Cause

The root cause is missing validation on type-loading inputs. The component loader trusts a configuration string or runtime parameter to identify a class to construct, then reflectively creates an instance. No allowlist of permitted assemblies, strong-name verification, or digital signature check prevents arbitrary types from being loaded from the filesystem.

Attack Vector

Exploitation requires an authenticated account and the ability to drop a file (such as a .NET assembly) onto the host that the service process can read. The attacker then references the malicious type through the vulnerable loader. On construction, the attacker's constructor code runs in-process. The attack vector is network-reachable, requires low privileges, and does not require user interaction. Refer to the CISA ICS Advisory ICSA-26-281-02 for vendor-specific exploitation details.

No verified public proof-of-concept code is available. See the CISA ICS
advisory and the Grid Protection Alliance release notes for technical
details on the vulnerable loader and the parameters that drive type
construction.

Stop Remote Code Execution Before It Runs

Singularity™ Endpoint detects and blocks exploit attempts at machine speed, including zero-days and novel attack techniques.

Stop Exploit Attempts

Detection Methods for CVE-2026-104629

Indicators of Compromise

  • Unexpected .dll or .exe assemblies appearing in openPDC or openHistorian installation, plugin, or working directories.
  • openPDC or openHistorian service processes loading modules from non-standard paths or user-writable directories.
  • Configuration changes referencing unfamiliar type names, assemblies, or component paths.
  • Child processes spawned by the openPDC or openHistorian service account that are inconsistent with normal operation.

Detection Strategies

  • Monitor file creation events in directories readable by the openPDC or openHistorian service, particularly for .NET assemblies dropped by authenticated users.
  • Alert on reflective assembly loads (Assembly.Load, Assembly.LoadFrom, Activator.CreateInstance) in process telemetry originating from the ICS service.
  • Correlate authenticated session activity with filesystem writes and subsequent service component reloads.

Monitoring Recommendations

  • Enable PowerShell and .NET assembly load logging on hosts running openPDC and openHistorian.
  • Forward Windows Security, Sysmon, and application event logs from ICS hosts to a centralized analytics platform for cross-host correlation.
  • Baseline the normal set of components loaded by openPDC and openHistorian services and alert on deviations.

How to Mitigate CVE-2026-104629

Immediate Actions Required

  • Inventory all hosts running openPDC and openHistorian and identify exposed instances per CISA ICS Advisory ICSA-26-281-02.
  • Restrict network access to management interfaces so that only operators from trusted administrative networks can authenticate.
  • Audit filesystem permissions on service installation and plugin directories to block writes by non-administrative accounts.
  • Review and reduce the privileges of the openPDC and openHistorian service accounts to the minimum required.

Patch Information

Consult the vendor advisory referenced in CISA ICS Advisory ICSA-26-281-02 and the CSAF document for fixed version numbers and upgrade guidance from the Grid Protection Alliance. Apply updates in a maintenance window with full configuration backups.

Workarounds

  • Place openPDC and openHistorian hosts behind firewalls and segment them from business IT networks, per standard ICS defense-in-depth guidance.
  • Require strong authentication and remove unused accounts that could satisfy the vulnerability's authentication prerequisite.
  • Enforce application allowlisting on ICS hosts so that only signed, approved assemblies can be loaded by the service process.
  • Monitor for and remove unauthorized files from directories accessible to the service account.
bash
# Example: audit filesystem ACLs on openPDC install directory (Windows)
icacls "C:\Program Files\openPDC" /T /C | findstr /I "Everyone Users Authenticated"

# Example: list recently modified assemblies in the service directory
Get-ChildItem -Path "C:\Program Files\openPDC" -Recurse -Include *.dll,*.exe |
  Where-Object { $_.LastWriteTime -gt (Get-Date).AddDays(-7) } |
  Select-Object FullName, LastWriteTime

Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.

Sources: National Vulnerability Database, CISA KEV, Exploit-DB

Experience the Most Advanced Cybersecurity Platform

See how the world’s most intelligent, autonomous cybersecurity platform can protect your organization today and into the future.