Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.
Sources: National Vulnerability Database, CISA KEV, Exploit-DB
CVE-2026-102006 Overview
CVE-2026-102006 is a kernel memory leak vulnerability in Wind River VxWorks 7 versions prior to 26.09. The flaw resides in the process management subsystem, which fails to release allocated kernel memory when specific system call arguments cause a calling application to terminate. Repeated invocation by a local, authenticated attacker can exhaust kernel memory and degrade availability of the real-time operating system. The issue is tracked under CWE-401: Missing Release of Memory after Effective Lifetime and is fixed in VxWorks 7 version 26.09.
Critical Impact
A local low-privileged process can trigger unbounded kernel memory consumption, leading to denial of service on VxWorks-based devices used in industrial, medical, aerospace, and networking systems.
Affected Products
- Wind River VxWorks 7 versions prior to 26.09
- Embedded systems and devices running vulnerable VxWorks 7 builds
- Real-time applications relying on the affected process management subsystem
Discovery Timeline
- 2026-09-28 - CVE-2026-102006 published to the National Vulnerability Database
- 2026-09-30 - CVE-2026-102006 last modified in NVD
Technical Details for CVE-2026-102006
Vulnerability Analysis
The vulnerability affects the process management subsystem of Wind River VxWorks 7, a real-time operating system deployed across embedded and safety-critical environments. When a process invokes certain system calls with specific argument combinations, the kernel allocates internal memory to service the request. If the calling application subsequently terminates along that code path, the allocated kernel memory is not freed. Each invocation leaks a bounded quantity of kernel memory. Repeated invocation from an unprivileged local process drains the kernel heap over time, eventually preventing new allocations and impacting system availability. Because VxWorks frequently runs on devices with tightly provisioned memory budgets, even modest leaks can render a device unresponsive.
Root Cause
The root cause is a missing memory release path in the process management subsystem [CWE-401]. The subsystem allocates kernel objects to satisfy a system call but does not deallocate them along the termination path of the calling application. Kernel memory ownership is not transferred to a cleanup routine, so the objects remain resident until reboot.
Attack Vector
Exploitation requires local access with low privileges and no user interaction. An attacker running arbitrary user-space code on the device can loop the vulnerable system call to exhaust kernel memory. The vulnerability affects availability only; confidentiality and integrity are not impacted. Remote exploitation is not indicated by the advisory. Consult the Wind River CVE Database for vendor guidance and affected build details.
Detection Methods for CVE-2026-102006
Indicators of Compromise
- Sustained decline in available kernel heap or free memory pools reported by VxWorks diagnostic utilities such as memShow or memPartShow.
- Unexplained task creation failures, allocation errors, or S_memLib_NOT_ENOUGH_MEMORY return codes on long-running devices.
- Unexpected device resets or watchdog-triggered reboots following periods of stable operation.
Detection Strategies
- Baseline kernel memory utilization on VxWorks devices and alert on monotonic downward trends that do not recover after workload cycles.
- Instrument critical embedded devices to export memory and task statistics through SNMP or serial telemetry for centralized analysis.
- Review process management syscall usage patterns from any user-space applications running on VxWorks targets.
Monitoring Recommendations
- Ingest VxWorks device telemetry, syslog, and memory metrics into a centralized analytics platform for longitudinal trend analysis.
- Correlate device reboots with preceding memory pressure events to identify potential exploitation attempts.
- Track deployed VxWorks build identifiers across the fleet to verify patch coverage for version 26.09.
How to Mitigate CVE-2026-102006
Immediate Actions Required
- Inventory all devices running Wind River VxWorks 7 and identify builds prior to 26.09.
- Restrict local execution on affected devices to trusted applications and remove unnecessary user-space code paths.
- Enable memory monitoring and automated alerting on kernel heap consumption for exposed devices.
Patch Information
Wind River has fixed the vulnerability in VxWorks 7 version 26.09. Operators should update affected images to 26.09 or later and redeploy firmware to production devices following standard change-control processes. Vendor advisory details are available through the Wind River CVE Database.
Workarounds
- Limit which unprivileged applications can invoke the affected process management system calls where the runtime permits such restrictions.
- Schedule controlled reboots on long-running devices to reset kernel memory state until patches are applied.
- Segment VxWorks devices onto isolated management networks to reduce the population of local actors capable of running code on them.
# Example: check available memory on a VxWorks target from the kernel shell
-> memShow
-> memPartShow memSysPartId, 1
Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.
Sources: National Vulnerability Database, CISA KEV, Exploit-DB

