Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.
Sources: National Vulnerability Database, CISA KEV, Exploit-DB
CVE-2026-101024 Overview
CVE-2026-101024 is a relative path traversal vulnerability in Satel Netco Design versions prior to v2.1.7. The flaw resides in the application's data export functionality. An authenticated user holding only Viewer privileges can write attacker-controlled content to file system locations accessible to the application service. The weakness is tracked under CWE-23: Relative Path Traversal.
Critical Impact
Successful exploitation enables unauthorized file creation or modification and, under specific conditions, arbitrary code execution on the host running Netco Design.
Affected Products
- Satel Netco Design versions prior to v2.1.7
Discovery Timeline
- 2026-10-08 - CVE-2026-101024 published to NVD
- 2026-10-09 - Last updated in NVD database
Technical Details for CVE-2026-101024
Vulnerability Analysis
The vulnerability affects the data export feature of Satel Netco Design. The export routine accepts user-influenced input used to construct destination file paths without properly normalizing or validating path separators and traversal sequences.
Because the application service writes files on behalf of the authenticated user, an attacker with Viewer-level credentials can redirect writes outside the intended export directory. This primitive allows overwriting application configuration, scripts, or scheduled task files that the service account can access.
The advisory notes that, under certain conditions, this write primitive escalates to arbitrary code execution. Code execution typically occurs when the attacker overwrites a file that is subsequently loaded, executed, or interpreted by the host or by the Netco Design service itself.
Root Cause
The root cause is improper neutralization of relative path sequences such as ../ within the file path parameters consumed by the export functionality. The application fails to canonicalize the resolved path and enforce containment within a designated export directory.
Attack Vector
Exploitation requires network access to the application and valid credentials with Viewer privileges. The attack vector is remote over the network with low attack complexity and no user interaction. Viewer is the lowest-privilege role in Netco Design, which lowers the authentication barrier for exploitation.
The vulnerability is described in prose only; no public proof-of-concept has been released. Technical details are available in the CISA ICS Advisory ICSA-26-281-03 and the corresponding GitHub CSAF Document.
Detection Methods for CVE-2026-101024
Indicators of Compromise
- Files written by the Netco Design service account outside the designated export directory.
- Export requests containing path traversal sequences such as ../, ..\, or URL-encoded variants (%2e%2e%2f).
- Unexpected modification of application binaries, configuration files, or startup scripts belonging to the Netco Design installation.
Detection Strategies
- Review application logs for export operations initiated by Viewer-role accounts, particularly those targeting unusual filenames or extensions.
- Enable file integrity monitoring on the Netco Design installation directory and any directory writable by its service account.
- Alert on process creation events where the Netco Design service writes to system paths, scheduled task folders, or web-accessible directories.
Monitoring Recommendations
- Baseline normal export destinations and alert on deviations.
- Correlate authentication events for Viewer accounts with subsequent export API calls to identify abuse patterns.
- Monitor network traffic to the Netco Design management interface for anomalous request volumes from a single authenticated session.
How to Mitigate CVE-2026-101024
Immediate Actions Required
- Upgrade Satel Netco Design to version v2.1.7 or later.
- Audit all accounts with Viewer privileges and remove any that are not strictly required.
- Rotate credentials for Viewer accounts that may have been exposed.
- Restrict network access to the Netco Design management interface to trusted operator networks only.
Patch Information
Satel addresses the vulnerability in Netco Design v2.1.7. Refer to the CISA ICS Advisory ICSA-26-281-03 for vendor patch details and upgrade guidance.
Workarounds
- If immediate patching is not feasible, disable or restrict the data export functionality for low-privileged roles.
- Run the Netco Design service under a least-privilege account that cannot write to sensitive system or application paths.
- Place the application behind a reverse proxy or firewall that enforces authenticated access and inspects request parameters for traversal sequences.
Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.
Sources: National Vulnerability Database, CISA KEV, Exploit-DB

