Skip to main content

CVE-2025-5742: Web Server Configuration XSS Vulnerability

CVE-2025-5742 is a cross-site scripting flaw affecting web server configuration parameters that allows authenticated attackers to inject malicious scripts. This article covers technical details, impact analysis, and mitigation strategies.

Published:

Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.

Sources: National Vulnerability Database, CISA KEV, Exploit-DB

CVE-2025-5742 Overview

CVE-2025-5742 is a Cross-Site Scripting (XSS) vulnerability [CWE-79] disclosed in a Schneider Electric product advisory (SEVD-2025-161-03). The flaw occurs when an authenticated user modifies configuration parameters on the embedded web server. Input is not properly neutralized before being rendered in subsequent web pages. An attacker who tricks an authenticated operator into viewing a crafted configuration value can execute script in the victim's browser context.

The issue affects the integrity and confidentiality of the browser session used to administer the device. Exploitation requires authenticated access to the web interface and user interaction with the malicious content.

Critical Impact

An authenticated attacker can inject script into configuration fields that executes in another user's browser, enabling session abuse and unauthorized actions against the industrial web server.

Affected Products

  • Schneider Electric product covered by advisory SEVD-2025-161-03 (consult vendor advisory for exact models and firmware versions)
  • Embedded web server configuration interface on the affected device
  • Browser sessions of authenticated administrators and operators

Discovery Timeline

  • 2025-06-10 - CVE-2025-5742 published to NVD
  • 2026-06-17 - Last updated in NVD database

Technical Details for CVE-2025-5742

Vulnerability Analysis

The vulnerability is a stored Cross-Site Scripting issue in the web management interface of the affected Schneider Electric product. Configuration parameters submitted by an authenticated user are stored and later rendered without proper output encoding. When another user loads a page that displays the tainted value, the injected markup is interpreted as script by the browser.

Because the payload persists in device configuration, exploitation does not require the attacker to maintain a session when the victim is targeted. Any administrator or operator who views the affected configuration page triggers execution. The script runs with the privileges of the viewing user within the web application origin.

Successful exploitation can lead to theft of session identifiers, forced configuration changes through authenticated requests, and manipulation of the user interface. In industrial control contexts, abuse of operator sessions can indirectly influence process-facing settings exposed by the device.

Root Cause

The web server fails to apply contextual output encoding on configuration parameter values before writing them into HTML responses. The vendor advisory classifies the weakness as CWE-79, Improper Neutralization of Input During Web Page Generation. Server-side input validation on the configuration endpoint is insufficient to block script-bearing values.

Attack Vector

The attack is network-reachable through the device web interface and requires low-privileged authentication plus user interaction, consistent with the CVSS 4.0 vector published by the vendor. An attacker with valid credentials submits a crafted value to a configuration parameter. A second authenticated user later browses a page that renders the stored value, at which point the injected script executes in their browser.

No verified public proof-of-concept code is available at the time of writing. Refer to the Schneider Electric Security Notice SEVD-2025-161-03 for parameter-specific technical details.

Detection Methods for CVE-2025-5742

Indicators of Compromise

  • Configuration parameter values that contain HTML tags, <script> fragments, javascript: URIs, or event handler attributes such as onerror= and onload=.
  • Unexpected modifications to configuration fields performed by low-privileged accounts outside normal change windows.
  • Browser console errors or Content Security Policy violation reports originating from the device web interface.

Detection Strategies

  • Inspect stored configuration exports for HTML or JavaScript syntax in fields that should contain plain text, numeric, or enumerated values.
  • Review web server access logs for POST or PUT requests to configuration endpoints with payloads containing angle brackets or URL-encoded script markers (%3Cscript).
  • Correlate configuration change events with subsequent authenticated administrator sessions that exhibit unusual request patterns.

Monitoring Recommendations

  • Forward device web server and audit logs to a centralized logging platform and alert on configuration changes made by non-administrative accounts.
  • Monitor browser-side telemetry on operator workstations for script execution originating from the device management origin.
  • Track authentication events on the embedded web interface to identify credential sharing or account misuse that would enable the first stage of this attack.

How to Mitigate CVE-2025-5742

Immediate Actions Required

  • Apply the fixed firmware version listed in Schneider Electric Security Notice SEVD-2025-161-03 as soon as it is validated for the environment.
  • Restrict access to the device web interface to a dedicated management network segment and trusted engineering workstations.
  • Audit existing configuration parameters and remove any values that contain HTML or script syntax.

Patch Information

Schneider Electric publishes remediation guidance, including fixed firmware versions and mitigation steps, in the referenced advisory SEVD-2025-161-03. Operators should follow the vendor's upgrade procedure and verify integrity of the firmware image before deployment.

Workarounds

  • Limit web interface accounts to the minimum number of users required and enforce role separation between configuration authors and reviewers.
  • Use a dedicated, hardened browser profile for device administration and disable browser-stored credentials for the management origin.
  • Place the device behind a firewall rule set that permits HTTPS access only from authorized engineering stations and jump hosts.

Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.

Sources: National Vulnerability Database, CISA KEV, Exploit-DB

Experience the Most Advanced Cybersecurity Platform

See how the world’s most intelligent, autonomous cybersecurity platform can protect your organization today and into the future.