CVE-2025-54927 Overview
CVE-2025-54927 is a path traversal vulnerability [CWE-22] disclosed in a Schneider Electric product. The flaw allows authenticated attackers to supply crafted path input that the system processes without proper validation. Successful exploitation grants unauthorized read access to sensitive files outside the intended directory scope.
The issue is network-exploitable but requires high privileges and no user interaction. The impact is limited to confidentiality, with no integrity or availability consequences recorded in the CVSS vector.
Critical Impact
Authenticated attackers can traverse directory boundaries and read sensitive files on affected Schneider Electric systems, exposing configuration data, credentials, or operational information.
Affected Products
- Schneider Electric product referenced in advisory SEVD-2025-224-02
- Refer to the vendor security notice for exact affected models and firmware versions
- No CPE identifiers were published in the NVD entry at disclosure
Discovery Timeline
- 2025-08-20 - CVE-2025-54927 published to NVD
- 2026-06-17 - Last updated in NVD database
Technical Details for CVE-2025-54927
Vulnerability Analysis
The vulnerability stems from improper limitation of a pathname to a restricted directory. The affected component accepts user-controlled path input and uses it to locate files on disk without sufficient canonicalization or allow-list checks.
An authenticated attacker can embed traversal sequences such as ../ or absolute path references in a request parameter. The application then resolves the manipulated path and returns file contents from locations outside the intended working directory.
The EPSS score at publication was approximately 0.595%, indicating low near-term exploitation probability in the broader threat landscape. Because the flaw requires valid credentials, exploitation is typically chained with credential compromise or insider access.
Root Cause
The root cause is missing or incomplete path sanitization in a file-handling routine. Normalization steps that would collapse .. sequences and compare the resolved path against an allowed base directory are not enforced before the file read operation occurs.
Attack Vector
The attack vector is network-based. An authenticated user sends a request containing a crafted path parameter to the affected service. The service resolves the traversal sequence and returns the targeted file content in the response, disclosing data the user is not authorized to access.
See the Schneider Electric Security Notice SEVD-2025-224-02 for product-specific technical details.
Detection Methods for CVE-2025-54927
Indicators of Compromise
- Request logs containing ../, ..\\, URL-encoded %2e%2e%2f, or double-encoded traversal sequences in path parameters
- Unexpected file read access by authenticated service accounts to system directories or configuration files
- Repeated 200-status responses to requests referencing paths outside documented application directories
Detection Strategies
- Deploy web application firewall rules that flag traversal patterns in query strings, body parameters, and headers
- Correlate authentication events with abnormal file access patterns originating from the affected Schneider Electric component
- Baseline normal file access behavior per account and alert on deviations such as reads of /etc/, credential stores, or firmware images
Monitoring Recommendations
- Enable verbose request and file access logging on the affected device management interfaces
- Forward logs to a centralized SIEM for retention and correlation across sessions
- Monitor privileged account activity continuously, since exploitation requires high privileges per the CVSS vector
How to Mitigate CVE-2025-54927
Immediate Actions Required
- Review the Schneider Electric Security Notice SEVD-2025-224-02 to identify affected products and firmware versions in your environment
- Apply vendor-supplied firmware or software updates once available for your product family
- Rotate credentials for privileged accounts that interact with the affected component
Patch Information
Schneider Electric publishes remediation guidance in advisory SEVD-2025-224-02. Consult that document for fixed firmware versions, mitigation steps, and product-specific instructions. Apply updates through standard change-control procedures used for operational technology environments.
Workarounds
- Restrict network access to the affected management interfaces using firewall rules and segmentation
- Enforce least-privilege account policies to limit the number of users capable of reaching the vulnerable code path
- Place the affected systems behind a jump host with session recording to detect misuse by authorized operators
# Example network restriction using iptables to limit management access
iptables -A INPUT -p tcp --dport <mgmt_port> -s <trusted_subnet> -j ACCEPT
iptables -A INPUT -p tcp --dport <mgmt_port> -j DROP