Skip to main content
CVE Vulnerability Database
Vulnerability Database/CVE-2025-40582

CVE-2025-40582: Siemens Scalance Privilege Escalation Flaw

CVE-2025-40582 is a privilege escalation vulnerability in Siemens Scalance LPE9403 firmware allowing local attackers to execute root commands. This article covers technical details, affected versions, and mitigation.

Updated:

CVE-2025-40582 Overview

CVE-2025-40582 is a command injection vulnerability affecting Siemens SCALANCE LPE9403 (6GK5998-3GS00-2AC2) devices running any firmware version with the SINEMA Remote Connect Edge Client installed. The device fails to properly sanitize configuration parameters processed by the client. A non-privileged local attacker can leverage this weakness to inject operating system commands that execute with root privileges. The flaw is classified under CWE-78, Improper Neutralization of Special Elements used in an OS Command. Siemens documented the issue in advisory SSA-327438.

Critical Impact

A local, low-privileged user can escalate to root on affected SCALANCE LPE9403 edge computing devices, compromising the confidentiality, integrity, and availability of industrial network operations.

Affected Products

  • Siemens SCALANCE LPE9403 (6GK5998-3GS00-2AC2) — all firmware versions with SINEMA Remote Connect Edge Client installed
  • Siemens SCALANCE LPE9403 firmware (all versions)
  • Deployments integrating the SINEMA Remote Connect Edge Client on LPE9403 hardware

Discovery Timeline

  • 2025-05-13 - CVE-2025-40582 published to the NVD
  • 2026-06-17 - Last updated in the NVD database

Technical Details for CVE-2025-40582

Vulnerability Analysis

The SCALANCE LPE9403 is a Linux-based edge computing platform designed for industrial network deployments. When the SINEMA Remote Connect Edge Client is installed, the device accepts configuration parameters that are passed to underlying operating system utilities without adequate neutralization of shell metacharacters. An authenticated local user with limited privileges can inject shell commands into these parameters. The injected payload then executes within a process running as root, granting the attacker full control of the device.

Exploitation requires local access and low privileges, but no user interaction. Because industrial edge devices commonly bridge operational technology (OT) and enterprise networks, a compromised LPE9403 can be leveraged as a pivot point into segmented control system environments.

Root Cause

The root cause is missing input sanitization in code paths that consume configuration parameters and pass them to shell interpreters or command execution primitives. The affected component does not enforce allow-list validation, does not escape shell metacharacters (such as ;, |, `, $()), and does not use safe process-invocation APIs that avoid interpreting arguments as shell syntax. This omission maps to CWE-78.

Attack Vector

An attacker must first gain local, authenticated access to the device — for example, through a low-privileged shell account or a management interface reachable from a compromised host. The attacker then submits a crafted configuration value containing shell metacharacters. When the SINEMA Remote Connect Edge Client processes the value using a privileged helper, the injected commands execute as root. See the Siemens ProductCERT advisory SSA-327438 for vendor-provided technical details.

// No verified proof-of-concept has been published for CVE-2025-40582.
// Refer to Siemens advisory SSA-327438 for the authoritative technical description.

Detection Methods for CVE-2025-40582

Indicators of Compromise

  • Unexpected root-owned processes spawned as children of the SINEMA Remote Connect Edge Client service on LPE9403 devices.
  • Configuration parameter values containing shell metacharacters such as ;, &&, |, backticks, or $().
  • Anomalous outbound network connections originating from the LPE9403 to non-Siemens infrastructure.
  • Unexplained modification of /etc, cron entries, or persistence artifacts on the device filesystem.

Detection Strategies

  • Audit stored SINEMA Remote Connect configuration parameters for characters outside the expected value grammar.
  • Correlate local authentication events on the LPE9403 with subsequent privilege transitions to UID 0.
  • Baseline the expected process tree of the SINEMA Edge Client and alert on deviations.
  • Compare firmware and package hashes against the vendor-signed baseline to identify tampering.

Monitoring Recommendations

  • Forward syslog and audit logs from SCALANCE LPE9403 devices to a centralized SIEM for retention and analysis.
  • Monitor OT-to-IT network flows for anomalous egress from edge devices.
  • Restrict and log access to management interfaces, and alert on repeated configuration changes from non-administrative accounts.

How to Mitigate CVE-2025-40582

Immediate Actions Required

  • Review Siemens advisory SSA-327438 and apply the vendor-recommended fix or update as soon as it is available for your firmware track.
  • Restrict local access to the SCALANCE LPE9403 to trusted administrators only, and remove unnecessary local user accounts.
  • Place affected devices behind properly configured cell protection firewalls in line with Siemens operational guidelines for industrial security.
  • Rotate credentials used to access the LPE9403 and the SINEMA Remote Connect Edge Client after remediation.

Patch Information

Siemens provides remediation guidance in Security Advisory SSA-327438. Operators should consult that advisory for the specific fixed version and update procedure applicable to their SCALANCE LPE9403 deployment and installed SINEMA Remote Connect Edge Client release.

Workarounds

  • Uninstall or disable the SINEMA Remote Connect Edge Client on LPE9403 devices where the remote connectivity feature is not required.
  • Enforce network segmentation so that the LPE9403 management plane is only reachable from a hardened jump host.
  • Limit shell and configuration-management privileges to a minimal set of authenticated operators, and disable interactive local logins for service accounts.
bash
# Example: restrict management access to a dedicated administrative subnet
# (adapt to your environment; consult Siemens hardening guidance).
iptables -A INPUT -p tcp --dport 22 -s 10.10.20.0/24 -j ACCEPT
iptables -A INPUT -p tcp --dport 22 -j DROP

Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.

Default Legacy - Prefooter | Experience the World’s Most Advanced Cybersecurity Platform

Experience the Most Advanced Cybersecurity Platform

See how the world’s most intelligent, autonomous cybersecurity platform can protect your organization today and into the future.