Skip to main content
Vulnerability Database/CVE-2025-40569

CVE-2025-40569: Siemens SCALANCE Race Condition Vulnerability

CVE-2025-40569 is a race condition flaw in Siemens SCALANCE and RUGGEDCOM network devices that allows authenticated attackers to inject malicious configurations. This post explains its impact, affected versions, and mitigation steps.

Published:

Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.

Sources: National Vulnerability Database, CISA KEV, Exploit-DB

CVE-2025-40569 Overview

CVE-2025-40569 is a race condition vulnerability [CWE-362] affecting Siemens RUGGEDCOM RST2428P and multiple SCALANCE XCH, XCM, XRH, and XRM industrial switches. The flaw resides in the Load Configuration from Local PC functionality of the web interface. An authenticated remote attacker can win a race condition during a legitimate administrator's configuration upload and cause the device to load an attacker-controlled configuration file instead.

Critical Impact

Successful exploitation allows an authenticated attacker to overwrite device configuration, enabling network segmentation changes, routing manipulation, or persistent control of affected industrial networking equipment.

Affected Products

  • RUGGEDCOM RST2428P (6GK6242-6PA00) — all versions prior to V3.2
  • SCALANCE XCH328, XCM324, XCM328, XCM332 — all versions prior to V3.2
  • SCALANCE XRH334 and XRM334 variants — all versions prior to V3.2

Discovery Timeline

  • 2025-06-10 - CVE-2025-40569 published to the National Vulnerability Database (NVD)
  • 2026-06-17 - Last updated in NVD database

Technical Details for CVE-2025-40569

Vulnerability Analysis

The vulnerability affects the configuration upload workflow in the web management interface of multiple Siemens industrial Ethernet switches. The Load Configuration from Local PC feature does not atomically bind the uploaded file to the invoking administrator session. Between the time the administrator triggers the upload and the time the device commits the configuration, another authenticated session can inject a substitute configuration file.

Exploitation requires that an authenticated attacker holds a valid session on the device and that an administrator initiates the configuration upload. The attacker must then time a competing request to replace the staged configuration before the device applies it. Because the integrity of applied device state depends on winning this race, the result is unauthorized modification of switch configuration without triggering the normal authentication boundary for administrative changes.

Root Cause

The root cause is a time-of-check to time-of-use (TOCTOU) weakness in the configuration-loading workflow. The web interface validates and stages the uploaded configuration in a shared resource that is not locked or scoped to the uploading session, allowing a concurrent request to overwrite the staged artifact before it is committed.

Attack Vector

The attack is network-based and requires low-privileged authenticated access to the web interface plus user interaction from a legitimate administrator. The attacker monitors or triggers an administrator's upload workflow, then races a crafted configuration into the staging path. Impact is limited to integrity of the device configuration; confidentiality and availability are not directly affected per the published vector.

The vulnerability is described in the Siemens Security Advisory SSA-693776. No public proof-of-concept code is available.

Detection Methods for CVE-2025-40569

Indicators of Compromise

  • Unexpected changes to switch configuration (VLANs, ACLs, routing, SNMP, user accounts) that do not correspond to a documented change ticket.
  • Overlapping or concurrent authenticated web sessions to the device management interface during a configuration upload window.
  • Device audit log entries showing configuration load events sourced from a non-administrator account or from an unexpected client IP.

Detection Strategies

  • Enable and centrally collect device audit and syslog events, then alert on configuration load or configuration apply entries that occur outside approved change windows.
  • Correlate web interface authentication logs with configuration-change events to identify sessions that interact with the upload endpoint concurrently with an administrator.
  • Baseline running configuration hashes and alert on unauthorized deltas between scheduled backups.

Monitoring Recommendations

  • Forward Siemens device syslog to a centralized SIEM or data lake and retain management-plane logs for forensic review.
  • Monitor management VLAN traffic for unexpected HTTP/HTTPS clients reaching the switch web interface.
  • Track administrator login patterns and flag simultaneous authenticated sessions from distinct source addresses.

How to Mitigate CVE-2025-40569

Immediate Actions Required

  • Upgrade affected RUGGEDCOM RST2428P and SCALANCE XCH/XCM/XRH/XRM334 devices to firmware V3.2 or later.
  • Restrict access to the device web management interface to a dedicated, isolated management network.
  • Rotate credentials for all accounts with web interface access and remove unused accounts.
  • Review current device configurations against a known-good backup to confirm no unauthorized changes are present.

Patch Information

Siemens addresses CVE-2025-40569 in firmware version V3.2 for all listed RUGGEDCOM and SCALANCE products. Refer to Siemens Security Advisory SSA-693776 for product-specific fixed versions and update instructions.

Workarounds

  • Limit web interface access to trusted administrative hosts using firewall rules or device-level access control lists.
  • Avoid performing Load Configuration from Local PC operations while other authenticated sessions are active on the device.
  • Prefer out-of-band configuration deployment channels (serial console or dedicated management VPN) until patches are applied.
bash
# Example: restrict management access on upstream firewall
# Replace addresses with your management subnet and device IP
iptables -A FORWARD -s 10.10.0.0/24 -d 192.0.2.10 -p tcp --dport 443 -j ACCEPT
iptables -A FORWARD -d 192.0.2.10 -p tcp --dport 443 -j DROP

Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.

Sources: National Vulnerability Database, CISA KEV, Exploit-DB

Experience the Most Advanced Cybersecurity Platform

See how the world’s most intelligent, autonomous cybersecurity platform can protect your organization today and into the future.