Skip to main content
Vulnerability Database/CVE-2025-31929

CVE-2025-31929: Siemens EV Chargers RCE Vulnerability

CVE-2025-31929 is a remote code execution vulnerability in Siemens VersiCharge and IEC electric vehicle charging devices caused by missing Immutable Root of Trust. This post covers technical details, affected products, and mitigation.

Published:

Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.

Sources: National Vulnerability Database, CISA KEV, Exploit-DB

CVE-2025-31929 Overview

CVE-2025-31929 affects a broad range of Siemens VersiCharge electric vehicle (EV) charging stations. The devices lack an Immutable Root of Trust in their M0 hardware component. An attacker with physical access to a charger can leverage this weakness to execute arbitrary code on the device.

The vulnerability is tracked under CWE-1326: Missing Immutable Root of Trust in Hardware. Because exploitation requires physical access and high attack complexity, the risk profile differs from remotely exploitable firmware issues. However, successful exploitation compromises the integrity of the charger's firmware trust chain.

Critical Impact

Physical attackers can bypass firmware integrity controls and execute arbitrary code on affected Siemens VersiCharge EV chargers, undermining the trust boundary between hardware and firmware.

Affected Products

  • Siemens IEC 1Ph 7.4kW VersiCharge units (part numbers 8EM1310-2E*, all versions)
  • Siemens IEC 3Ph 22kW VersiCharge units (part numbers 8EM1310-3E* and 8EM1310-3F*, all versions)
  • Siemens UL Commercial and Residential VersiCharge units, including VersiCharge Blue 80A AC Cellular (8EM1315-7BG16-1FH2), all versions

Discovery Timeline

  • 2025-05-13 - CVE-2025-31929 published to NVD
  • 2026-06-17 - Last updated in NVD database

Technical Details for CVE-2025-31929

Vulnerability Analysis

The affected VersiCharge chargers rely on an M0-class microcontroller that does not implement an Immutable Root of Trust (RoT). An Immutable Root of Trust is a hardware-anchored verification mechanism that cryptographically validates firmware before execution. Without it, the first stage of the boot process cannot be guaranteed to be authentic.

An attacker with physical access to the charger can modify or replace firmware on the M0 component. The device will boot and execute the attacker-supplied code because no hardware-enforced check compares the firmware against a known-good signature. This breaks the secure boot chain for every subsequent stage.

Exploitation requires opening the charger enclosure and interacting with debug or programming interfaces on the M0 processor. The attacker must have hardware knowledge and tooling, which raises attack complexity. The result is persistent code execution that survives reboots and standard firmware updates.

Root Cause

The root cause is a hardware design decision. The M0 processor used in the affected VersiCharge product line does not include an immutable boot ROM that enforces signature verification on executable code. Firmware integrity therefore depends entirely on physical access controls rather than cryptographic guarantees anchored in silicon.

Attack Vector

The attack vector is physical. An adversary with hands-on access to the charger can connect to the M0 microcontroller through programming or debug pins and write arbitrary code to flash storage. Remote exploitation over the network is not possible for this specific weakness. See the Siemens Security Advisory SSA-556937 for Siemens' technical guidance.

No verified exploit code is available. Refer to Siemens Security Advisory
SSA-556937 for technical details on the affected hardware boot chain.

Stop Remote Code Execution Before It Runs

Singularity™ Endpoint detects and blocks exploit attempts at machine speed, including zero-days and novel attack techniques.

Stop Exploit Attempts

Detection Methods for CVE-2025-31929

Indicators of Compromise

  • Physical tamper evidence on charger enclosures, including broken seals, scratches around screws, or missing security labels
  • Unexpected changes in device firmware version strings, serial numbers, or management console telemetry
  • Chargers reporting anomalous network traffic, new outbound connections, or unexpected cellular/SIM activity

Detection Strategies

  • Deploy tamper-evident seals and physical intrusion sensors on charger housings and audit them on a regular schedule
  • Compare firmware checksums and version metadata collected from the fleet against a known-good baseline maintained by the operator
  • Monitor the backend charging management platform for devices that drop offline, re-register with new identifiers, or exhibit configuration drift

Monitoring Recommendations

  • Centralize charger logs and OCPP (Open Charge Point Protocol) telemetry for correlation and anomaly review
  • Alert on any administrative or diagnostic session originating from the local service port of a charger
  • Review surveillance footage covering charger locations when tamper indicators or telemetry anomalies trigger

How to Mitigate CVE-2025-31929

Immediate Actions Required

  • Inventory all deployed Siemens VersiCharge units against the part numbers listed in Siemens Advisory SSA-556937
  • Restrict physical access to chargers through fencing, bollards, locked enclosures, lighting, and surveillance
  • Apply tamper-evident seals to enclosure fasteners and document their state during routine inspections
  • Follow Siemens' operational guidance in the referenced advisory for any available compensating configurations

Patch Information

Siemens has not published a hardware fix that retrofits an Immutable Root of Trust to deployed M0 components, because the weakness is anchored in silicon design. Operators must consult the Siemens Security Advisory SSA-556937 for the current remediation guidance, including any firmware updates or hardware revisions that address the underlying trust chain.

Workarounds

  • Enforce physical security controls as the primary compensating mitigation, since the vulnerability requires physical access
  • Isolate charger management networks from corporate and operational technology networks to limit lateral impact if a charger is compromised
  • Rotate credentials, API keys, and certificates stored on or associated with chargers that show tamper indicators
  • Replace suspected tampered units and perform forensic review before returning them to service
bash
# Example: physical inspection checklist entry (operator runbook)
# 1. Verify tamper-evident seal ID matches deployment record
# 2. Record firmware version reported by the management platform
# 3. Compare against baseline hash list; flag any mismatch
# 4. Escalate flagged units for offline forensic review

Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.

Sources: National Vulnerability Database, CISA KEV, Exploit-DB

Experience the Most Advanced Cybersecurity Platform

See how the world’s most intelligent, autonomous cybersecurity platform can protect your organization today and into the future.