Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.
Sources: National Vulnerability Database, CISA KEV, Exploit-DB
CVE-2025-27448 Overview
CVE-2025-27448 is a stored cross-site scripting (XSS) vulnerability affecting Endress MEAC300-FNADE4 firmware. The web application allows authenticated users with dashboard creation privileges to inject JavaScript into the dashboard name field. The injected script executes in the browser of any user who loads the dashboard view, resulting in script execution under the victim's session context. The issue is tracked under [CWE-79] and disclosed through the SICK Product Security Incident Response Team advisory SCA-2025-0008.
Critical Impact
An authenticated attacker can persist JavaScript in dashboard names to hijack sessions, exfiltrate data, or perform actions on behalf of other operators of the industrial monitoring interface.
Affected Products
- Endress MEAC300-FNADE4 hardware
- Endress MEAC300-FNADE4 firmware
- Web dashboard component of the MEAC300-FNADE4 emissions monitoring system
Discovery Timeline
- 2025-07-03 - CVE-2025-27448 published to NVD
- 2026-06-17 - Last updated in NVD database
Technical Details for CVE-2025-27448
Vulnerability Analysis
The MEAC300-FNADE4 web application fails to sanitize user-supplied input in the dashboard name field. When a user with dashboard-creation privileges submits a name containing HTML or JavaScript payloads, the application stores the raw value in persistent storage. The dashboard view later renders that value in the HTML response without contextual output encoding.
Any subsequent user who loads the dashboard triggers execution of the embedded script in their browser. Because the payload is stored server-side, the attack persists across sessions and affects every viewer of the affected dashboard. This is a stored XSS pattern classified under [CWE-79] Improper Neutralization of Input During Web Page Generation.
Root Cause
The root cause is missing input validation on write and missing output encoding on read within the dashboard name handling code path. The rendering routine emits the stored string directly into the HTML document instead of encoding characters such as <, >, ", ', and & for the HTML body context.
Attack Vector
Exploitation requires an authenticated account with permission to create dashboards and a victim user who loads the malicious dashboard in a browser. The attack chain is:
- The attacker authenticates to the MEAC300-FNADE4 web interface.
- The attacker creates a new dashboard whose name contains a JavaScript payload embedded in an HTML tag or event handler.
- A second user opens the dashboard listing or the dashboard itself.
- The victim's browser parses the stored payload and executes it in the origin of the device's web application.
Because the scope metric in the CVSS vector is Changed, script execution can affect resources beyond the vulnerable component, including cookies and tokens bound to the same origin. Refer to the SICK CSAF advisory for vendor-supplied technical details.
Detection Methods for CVE-2025-27448
Indicators of Compromise
- Dashboard entities whose name field contains HTML tags, angle brackets, javascript: URIs, or event-handler attributes such as onerror= or onload=.
- Unexpected outbound HTTP requests from operator workstations shortly after loading the MEAC300-FNADE4 dashboard interface.
- Newly created dashboards from accounts that do not normally author dashboards.
Detection Strategies
- Query the device configuration store or database for dashboard name values containing <, >, or on[a-z]+= patterns.
- Inspect web server access logs for dashboard-creation requests with payloads that include script tags or HTML entities.
- Deploy browser-side content security policy (CSP) reporting to surface inline script execution originating from the MEAC300-FNADE4 web origin.
Monitoring Recommendations
- Alert on POST or PUT requests to the dashboard API where the name parameter contains angle brackets or common XSS keywords.
- Monitor operator workstation network telemetry for connections to unfamiliar external hosts after sessions with the device UI.
- Review audit logs for dashboard-creation events performed outside normal maintenance windows.
How to Mitigate CVE-2025-27448
Immediate Actions Required
- Apply the firmware update referenced in the SICK PSIRT advisory SCA-2025-0008 as soon as it is available for your MEAC300-FNADE4 revision.
- Restrict dashboard-creation privileges to a minimal set of trusted operator accounts.
- Audit existing dashboards and remove or rename any entries containing HTML or script content.
- Isolate the MEAC300-FNADE4 web interface on a management network segment that is not reachable from general corporate zones.
Patch Information
Endress and SICK coordinate remediation for the MEAC300-FNADE4 through the SICK PSIRT process. Consult the SICK PSIRT portal and the CSAF document SCA-2025-0008 for fixed firmware versions and update procedures. Follow the CISA ICS Recommended Practices when scheduling maintenance on operational technology assets.
Workarounds
- Limit access to the web interface to hardened, dedicated engineering workstations that do not browse the general internet in the same session.
- Enforce a strict Content Security Policy at any reverse proxy in front of the device to block inline script execution.
- Require dual review for any dashboard configuration change until the patched firmware is deployed.
- Disable or remove operator accounts that no longer require dashboard authoring rights.
# Example reverse-proxy CSP header to block inline scripts from the device UI
add_header Content-Security-Policy "default-src 'self'; script-src 'self'; object-src 'none'; base-uri 'self'; frame-ancestors 'none'";
Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.
Sources: National Vulnerability Database, CISA KEV, Exploit-DB