Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.
Sources: National Vulnerability Database, CISA KEV, Exploit-DB
CVE-2025-25984 Overview
CVE-2025-25984 affects the Macro-video Technologies V380E6_C1 IP camera running firmware version 1020302 (hardware revision Hw_HsAKPIQp_WF_XHR). The flaw lets a physically proximate attacker execute arbitrary code through the device's Universal Asynchronous Receiver-Transmitter (UART) component. The weakness maps to [CWE-259: Use of Hard-coded Password], indicating credential material on the serial debug interface permits unauthorized shell access. Exploitation requires physical access to the camera enclosure to reach the exposed UART pads on the printed circuit board.
Critical Impact
An attacker with brief physical access to the camera can gain a privileged shell through UART, leading to full compromise of device confidentiality, integrity, and availability.
Affected Products
- Macro-video V380E6_C1 IP camera (hardware revision Hw_HsAKPIQp_WF_XHR)
- Macro-video V380E6_C1 firmware version 1020302
- Downstream V380-branded camera deployments using the same firmware image
Discovery Timeline
- 2025-04-18 - CVE-2025-25984 published to the National Vulnerability Database
- 2026-06-17 - Last updated in NVD database
Technical Details for CVE-2025-25984
Vulnerability Analysis
The V380E6_C1 IP camera exposes a UART debug interface on its circuit board. An attacker who opens the device chassis can solder or clip onto the TX, RX, and ground pads to establish a serial console session. The firmware grants interactive access through this interface without enforcing a strong, device-unique authentication boundary. Once connected, the attacker reaches a shell context capable of running arbitrary commands against the camera's embedded Linux environment.
From that shell, an operator can read sensitive configuration data, extract Wi-Fi credentials, dump firmware for offline analysis, pivot to the cloud service account bound to the device, or install persistent implants. The physical attack vector limits scale, but the impact on confidentiality, integrity, and availability is complete per the CVSS vector AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H.
Root Cause
The root cause is the retention of a hard-coded or weakly protected credential path on the UART debug interface in production firmware. Debug consoles that should be disabled or gated by secure boot and signed authentication remain available on shipped units. See the GitHub CVE-2025-25984 research write-up for the credential and bootloader details documented by the researcher.
Attack Vector
Exploitation follows a standard hardware-hacking workflow. The attacker disassembles the camera, identifies the UART test points, attaches a USB-to-TTL adapter at the matching baud rate, and interacts with the serial console during or after boot. No network exposure is required, and no user interaction occurs on the camera owner's side. The attack is suited to supply-chain tampering, evil-maid scenarios in physical security deployments, and devices recovered from rental or secondhand channels.
See the V380 IP camera research repository for the full reverse-engineering notes.
Stop Remote Code Execution Before It Runs
Singularity™ Endpoint detects and blocks exploit attempts at machine speed, including zero-days and novel attack techniques.
Stop Exploit AttemptsDetection Methods for CVE-2025-25984
Indicators of Compromise
- Physical signs of tampering such as removed screws, pry marks, broken warranty seals, or exposed solder on the UART header
- Unexpected outbound connections from the camera to IP addresses outside the vendor's cloud service ranges
- Changes to on-device configuration files, new cron entries, or unknown processes observable after a firmware re-flash and inspection
Detection Strategies
- Periodically image affected cameras and diff firmware partitions against a known-good baseline from the vendor
- Baseline each camera's network behavior and alert on new destinations, protocols, or ports
- Correlate physical access logs with camera reboot events and configuration changes
Monitoring Recommendations
- Segment IP cameras onto an isolated VLAN and log all north-south and east-west traffic through a network sensor
- Forward DHCP, DNS, and NetFlow records from the camera VLAN into a central analytics platform for anomaly review
- Monitor physical access control logs for the rooms or enclosures that house V380E6_C1 units
How to Mitigate CVE-2025-25984
Immediate Actions Required
- Inventory all Macro-video V380E6_C1 cameras running firmware 1020302 and record their physical locations
- Restrict physical access to deployed cameras using locked enclosures, tamper-evident seals, and surveillance of install sites
- Isolate the cameras on a dedicated network segment with egress filtering to vendor cloud endpoints only
Patch Information
No vendor advisory or patched firmware has been published in the enriched data for CVE-2025-25984. Operators should contact Macro-video Technologies for firmware updates and monitor the NVD record and the researcher's GitHub repository for remediation status.
Workarounds
- Mount cameras in tamper-resistant housings that cover the circuit board and screw heads
- Replace affected units in high-sensitivity environments with cameras that disable UART in production firmware or require signed access tokens
- Rotate any Wi-Fi, cloud account, and shared credentials previously provisioned to a camera suspected of physical tampering
# Example egress restriction for a camera VLAN on a Linux gateway
iptables -A FORWARD -i vlan_cameras -p tcp --dport 443 -d <vendor_cloud_cidr> -j ACCEPT
iptables -A FORWARD -i vlan_cameras -j DROP
Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.
Sources: National Vulnerability Database, CISA KEV, Exploit-DB