Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.
Sources: National Vulnerability Database, CISA KEV, Exploit-DB
CVE-2025-24843 Overview
CVE-2025-24843 is an insecure file retrieval vulnerability disclosed in a Dario Health product ecosystem through CISA Medical Advisory ICSMA-25-058-01. The flaw allows a local actor to manipulate files retrieved by the product, undermining stability and the confidentiality, integrity, authenticity, and attestation of stored data. The issue is tracked under [CWE-921: Storage of Sensitive Data in a Mechanism without Access Control]. Because the vulnerability affects a connected medical device platform, exploitation carries clinical and privacy consequences beyond typical enterprise IT risk.
Critical Impact
A local attacker can substitute or tamper with files consumed by the device, degrading data integrity and attestation guarantees for health-related information.
Affected Products
- Dario Health product referenced in CISA Medical Advisory ICSMA-25-058-01
- Consult the vendor directly through Dario Health Contact Information for a definitive list of affected versions
- Specific product identifiers and CPE URIs were not published in the NVD entry
Discovery Timeline
- 2025-02-28 - CVE-2025-24843 published to the National Vulnerability Database (NVD)
- 2026-06-17 - Last updated in NVD database
Technical Details for CVE-2025-24843
Vulnerability Analysis
The vulnerability stems from an insecure file retrieval process. The affected product loads files from a storage mechanism that lacks sufficient access control, matching the pattern described by [CWE-921]. An actor with local access to the storage location can replace, modify, or inject files that the product later reads and trusts.
Because the retrieval path does not enforce integrity or authenticity checks, the product cannot distinguish between legitimate files and attacker-supplied substitutes. This weakens attestation over stored data and creates downstream effects on product stability. In a medical device context, that data may include configuration, calibration, or health-record artifacts.
The attack requires local access and no privileges or user interaction, but the impact is bounded to limited integrity and availability outcomes on the vulnerable component. Confidentiality is not directly compromised through this weakness alone.
Root Cause
The root cause is the absence of access control and integrity validation on the storage mechanism used for file retrieval. Files placed in the retrieval path are consumed without cryptographic verification, permission checks, or provenance validation. This design pattern permits substitution attacks whenever an actor can write to the storage location.
Attack Vector
Exploitation requires local access to the storage medium or file location that the product reads from. An attacker writes a crafted file into the retrieval path or modifies an existing one. When the product performs its next retrieval cycle, it ingests the tampered content, affecting stability and the trustworthiness of stored data.
No verified proof-of-concept code is public for CVE-2025-24843. Refer to CISA Medical Advisory ICSMA-25-058-01 for vendor-coordinated technical detail.
Detection Methods for CVE-2025-24843
Indicators of Compromise
- Unexpected file modifications, additions, or deletions in the product's data retrieval directories
- File hash mismatches between deployed artifacts and vendor-published baselines
- Product logs indicating failed integrity checks, parsing errors, or unexpected restarts tied to file ingestion
Detection Strategies
- Deploy file integrity monitoring (FIM) against known storage paths used by the affected device or companion software
- Baseline the size, hash, and permissions of files consumed during retrieval and alert on deviation
- Correlate local process activity with writes to sensitive storage locations to identify unauthorized modifiers
Monitoring Recommendations
- Forward device and endpoint telemetry into a centralized data lake for longitudinal review of file-write events
- Alert on any local account or process performing writes to the retrieval directory outside of documented workflows
- Track device stability metrics and correlate crashes with recent file changes to surface tampering attempts
How to Mitigate CVE-2025-24843
Immediate Actions Required
- Restrict physical and logical local access to systems that host the affected Dario Health product
- Contact the vendor via Dario Health Contact Information to confirm affected versions and obtain remediation guidance
- Review file system permissions on retrieval directories and remove write access for non-privileged users
- Enable file integrity monitoring on storage paths consumed by the product
Patch Information
No specific patch identifier is listed in the NVD entry for CVE-2025-24843. Follow the mitigation guidance published in CISA Medical Advisory ICSMA-25-058-01 and apply any firmware or software updates provided directly by Dario Health.
Workarounds
- Apply strict access control lists on the file storage locations used for retrieval
- Isolate affected devices on a segmented network to reduce local access exposure
- Verify file integrity out-of-band using vendor-published checksums before device use in clinical workflows
- Log and audit all local account activity on hosts that interact with the product
# Example: restrict permissions on a retrieval directory (Linux)
chown root:root /path/to/retrieval
chmod 750 /path/to/retrieval
auditctl -w /path/to/retrieval -p wa -k dario_file_tamper
Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.
Sources: National Vulnerability Database, CISA KEV, Exploit-DB