Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.
Sources: National Vulnerability Database, CISA KEV, Exploit-DB
CVE-2025-24812 Overview
CVE-2025-24812 is a denial-of-service vulnerability affecting Siemens SIMATIC S7-1200 and SIPLUS S7-1200 programmable logic controllers (PLCs) running firmware versions prior to V4.7. The affected devices fail to correctly process specially crafted packets sent to port 102/tcp, which handles the S7 communication protocol used for engineering and process control. An authenticated attacker with low privileges on the network can exploit this flaw to cause the device to enter a denial-of-service condition, disrupting industrial automation processes. The vulnerability is tracked under CWE-1286: Improper Validation of Syntactic Correctness of Input.
Critical Impact
Successful exploitation causes affected S7-1200 PLCs to enter a denial-of-service state, potentially halting industrial control processes and requiring device recovery to restore operations.
Affected Products
- SIMATIC S7-1200 CPU 1211C, 1212C, 1212FC, 1214C, 1214FC, 1215C, 1215FC, and 1217C variants (all versions prior to V4.7)
- SIPLUS S7-1200 CPU 1212, 1214, 1215 series variants (all versions prior to V4.7)
- Siemens S7 communication service exposed on port 102/tcp
Discovery Timeline
- 2025-02-11 - CVE-2025-24812 published to NVD
- 2026-06-17 - Last updated in NVD database
Technical Details for CVE-2025-24812
Vulnerability Analysis
The vulnerability resides in the S7 communication handler that listens on port 102/tcp on affected SIMATIC and SIPLUS S7-1200 PLCs. The device does not properly validate the syntactic structure of certain crafted packets received on this port. When a malformed packet reaches the handler, the resulting parsing failure leads to a denial-of-service condition on the controller.
Because S7-1200 controllers execute deterministic control loops in real-time industrial environments, any interruption to firmware processing can halt physical processes managed by the PLC. Operators may need to power-cycle or manually recover affected devices to restore normal operation.
Root Cause
The root cause is improper input validation classified under CWE-1286. The S7 protocol parser does not adequately verify syntactic correctness of incoming packet structures before processing them. This gap allows crafted inputs to trigger a fault condition in the firmware.
Attack Vector
An attacker requires network access to port 102/tcp on the target PLC and low-level authentication privileges. No user interaction is required. In typical operational technology (OT) environments where S7-1200 devices sit on flat or poorly segmented networks, an attacker who has gained a foothold on an adjacent host can reach the vulnerable service directly. Exploitation results in disruption of the PLC's availability without affecting confidentiality or integrity.
The vulnerability is described in prose only, as no verified public proof-of-concept code is available. Refer to the Siemens Security Advisory SSA-224824 for authoritative technical details.
Detection Methods for CVE-2025-24812
Indicators of Compromise
- Unexpected PLC restarts, communication timeouts, or STOP mode transitions on SIMATIC S7-1200 controllers
- Loss of connectivity to port 102/tcp on affected devices coinciding with unusual inbound traffic
- Anomalous or malformed S7 protocol traffic originating from non-engineering workstations
Detection Strategies
- Deploy OT-aware network monitoring to inspect S7 communication traffic destined for port 102/tcp and flag protocol violations
- Correlate PLC diagnostic buffer entries and controller availability events with network flow data around the time of disruptions
- Baseline authorized engineering stations that communicate with S7-1200 devices and alert on new or unexpected sources
Monitoring Recommendations
- Continuously monitor PLC uptime, cycle time, and CPU state to detect denial-of-service impact quickly
- Log and centralize all TCP 102 session attempts to detect scanning or repeated malformed connection patterns
- Integrate OT telemetry into the SOC through a unified data lake to correlate IT and OT events during incident triage
How to Mitigate CVE-2025-24812
Immediate Actions Required
- Inventory all SIMATIC S7-1200 and SIPLUS S7-1200 controllers and identify units running firmware earlier than V4.7
- Upgrade affected controllers to firmware V4.7 or later as published by Siemens
- Restrict network access to port 102/tcp on all PLCs to authorized engineering workstations only
- Segment PLC networks from enterprise IT networks using firewalls and unidirectional gateways where applicable
Patch Information
Siemens has released firmware version V4.7 and later for all affected SIMATIC S7-1200 and SIPLUS S7-1200 CPU models. Consult the Siemens Security Advisory SSA-224824 for model-specific update packages and installation instructions. Apply firmware updates during scheduled maintenance windows following change-control procedures for the affected process.
Workarounds
- Apply strict firewall rules to limit inbound TCP connections to port 102 to a small allowlist of engineering hosts
- Follow Siemens operational guidelines for securing industrial devices, including deployment behind cell-protection firewalls
- Disable or restrict the S7 communication service on devices that do not require remote engineering access
- Monitor OT networks for anomalous S7 protocol traffic and respond to abnormal PLC state changes
# Example firewall rule restricting access to S7 port 102/tcp
# Allow only trusted engineering workstation 10.10.1.25 to reach PLC 10.20.30.40
iptables -A FORWARD -p tcp -s 10.10.1.25 -d 10.20.30.40 --dport 102 -j ACCEPT
iptables -A FORWARD -p tcp -d 10.20.30.40 --dport 102 -j DROP