Skip to main content

CVE-2025-2440: Insecure Storage Information Disclosure

CVE-2025-2440 is an insecure storage vulnerability in radio devices that could allow unauthorized access to confidential data through factory reset exploitation. This article covers technical details, risk factors, and mitigation.

Published:

Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.

Sources: National Vulnerability Database, CISA KEV, Exploit-DB

CVE-2025-2440 Overview

CVE-2025-2440 is an Insecure Storage of Sensitive Information vulnerability [CWE-922] affecting a Schneider Electric radio device. The flaw allows an attacker with physical access and detailed knowledge of the device file system to recover confidential data by setting the radio into factory default mode. Because the reset process does not adequately protect stored sensitive information, residual data becomes accessible to a local attacker after the operation completes.

Critical Impact

An attacker with physical access can retrieve confidential data stored on the radio after triggering a factory default reset.

Affected Products

  • Schneider Electric radio device (see vendor advisory SEVD-2025-098-02 for affected models and firmware versions)

Discovery Timeline

  • 2025-04-09 - CVE-2025-2440 published to NVD
  • 2026-06-17 - Last updated in NVD database

Technical Details for CVE-2025-2440

Vulnerability Analysis

The vulnerability stems from how the affected radio device stores and handles sensitive information across a factory reset. Rather than securely wiping confidential material during the reset routine, the device leaves recoverable data on the file system. An attacker who understands the on-device storage layout can access this residual data after invoking factory default mode.

Exploitation is bounded by two requirements. First, the attacker must have physical access to the device. Second, the attacker must possess advanced knowledge of the internal file system structure. These preconditions raise the attack complexity and limit remote exposure, but do not eliminate risk in unattended deployments, shared environments, or supply-chain handling scenarios.

The impact is confined to confidentiality. Integrity and availability of the radio are not directly affected by this weakness. However, disclosed credentials, keys, or configuration material could be reused to attack other systems that trust the radio or share its secrets.

Root Cause

The root cause is improper handling of sensitive data during the factory default operation [CWE-922]. The reset process fails to cryptographically erase or otherwise sanitize stored secrets and configuration data before returning the device to its default state.

Attack Vector

The attack vector is physical. An attacker with hands-on access to the radio triggers factory default mode and then inspects the file system using specialized knowledge to locate and extract sensitive artifacts left behind by the incomplete reset.

No verified proof-of-concept code has been published. Refer to the Schneider Electric Security Notice SEVD-2025-098-02 for authoritative technical detail.

Detection Methods for CVE-2025-2440

Indicators of Compromise

  • Unexpected physical access events to radio devices, including opened enclosures, tamper-seal breakage, or missing units returned to inventory.
  • Radios discovered in a factory-default state without an approved maintenance ticket.
  • Anomalous authentication activity on systems that share credentials or keys with the affected radio.

Detection Strategies

  • Reconcile physical asset inventories with maintenance and reset logs to identify unauthorized factory resets.
  • Correlate badge and CCTV data with device management logs to detect physical access outside maintenance windows.
  • Rotate and monitor credentials or keys previously provisioned to any radio that entered factory default mode.

Monitoring Recommendations

  • Enable tamper detection and physical intrusion alerts on cabinets and enclosures hosting affected radios.
  • Forward device management and configuration-change events to a centralized log store for retention and analysis.
  • Track downstream authentication for any secrets that may have been stored on the affected device.

How to Mitigate CVE-2025-2440

Immediate Actions Required

  • Restrict physical access to affected radios using locked enclosures, controlled facilities, and access-badge policies.
  • Review the Schneider Electric Security Notice SEVD-2025-098-02 and apply vendor-supplied firmware updates.
  • Rotate any credentials, keys, or configuration secrets that were stored on devices exposed to untrusted physical access.

Patch Information

Schneider Electric addresses this vulnerability in advisory SEVD-2025-098-02. Consult the advisory for the list of affected models, fixed firmware versions, and vendor remediation guidance.

Workarounds

  • Enforce chain-of-custody procedures for radios during shipping, storage, and decommissioning.
  • Perform a documented secure-wipe procedure before decommissioning or transferring devices between environments.
  • Deploy tamper-evident seals and periodically audit them on all field-deployed units.
bash
# Configuration example not applicable - remediation is vendor firmware update.
# See Schneider Electric SEVD-2025-098-02 for firmware upgrade instructions.

Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.

Sources: National Vulnerability Database, CISA KEV, Exploit-DB

Experience the Most Advanced Cybersecurity Platform

See how the world’s most intelligent, autonomous cybersecurity platform can protect your organization today and into the future.