Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.
Sources: National Vulnerability Database, CISA KEV, Exploit-DB
CVE-2025-24004 Overview
CVE-2025-24004 affects Phoenix Contact CHARX SEC-3000 series electric vehicle charging controllers. A physical attacker with access to the device display via USB-C can send a crafted message that triggers an unsecure copy to a buffer. The flaw leads to loss of integrity and a temporary denial-of-service until the watchdog restarts the affected station. The weakness is classified as a classic buffer copy without checking size of input [CWE-120]. Phoenix Contact CHARX SEC-3000, SEC-3050, SEC-3100, and SEC-3150 charging controllers are affected.
Critical Impact
An attacker with physical USB-C access can corrupt device state and force a watchdog-triggered restart, interrupting EV charging operations.
Affected Products
- Phoenix Contact CHARX SEC-3000 and SEC-3050 charging controllers (firmware)
- Phoenix Contact CHARX SEC-3100 and SEC-3150 charging controllers (firmware)
- All firmware versions listed in CERT@VDE advisory VDE-2025-014
Discovery Timeline
- 2025-07-08 - CVE-2025-24004 published to the National Vulnerability Database
- 2026-06-17 - Entry last modified in NVD
Technical Details for CVE-2025-24004
Vulnerability Analysis
The flaw resides in the message-handling routine that processes data arriving from the device display over USB-C. The handler copies attacker-controlled input into a fixed-size buffer without validating the input length. This classic buffer copy weakness [CWE-120] allows adjacent memory to be overwritten. The resulting corruption breaks runtime integrity and leaves the device in an unrecoverable state. A hardware watchdog then forces a restart, producing a temporary denial-of-service on the affected charging station.
Root Cause
The root cause is missing bounds checking on message payloads received through the display interface. The copy operation trusts the length of the incoming message rather than enforcing the destination buffer size. CWE-120 ("Buffer Copy without Checking Size of Input") describes this pattern directly.
Attack Vector
Exploitation requires physical access to the device display and a USB-C connection. The attacker sends a crafted message that exceeds the expected buffer size. No authentication or user interaction is required once physical access is established. Successful exploitation does not disclose confidential data but corrupts integrity and triggers a watchdog-induced reboot of the charging station.
No verified proof-of-concept code is publicly available for CVE-2025-24004.
Refer to CERT@VDE advisory VDE-2025-014 for vendor-supplied technical details.
Detection Methods for CVE-2025-24004
Indicators of Compromise
- Unexpected station reboots preceded by USB-C device connections at the display port
- Watchdog reset events logged by the CHARX controller without a corresponding operational cause
- Service interruptions on charging sessions coinciding with on-site physical presence
Detection Strategies
- Correlate physical access logs, CCTV, and tamper sensors with controller restart events
- Monitor controller syslog or diagnostic exports for repeated watchdog-triggered restarts
- Review charging-session telemetry for abrupt terminations tied to specific stations
Monitoring Recommendations
- Forward CHARX controller logs to a centralized SIEM for anomaly detection
- Alert on any physical USB-C enumeration event at the display interface in production environments
- Track mean time between restarts per station and flag statistical outliers
How to Mitigate CVE-2025-24004
Immediate Actions Required
- Restrict physical access to the display and USB-C port on all CHARX SEC-3000 series stations
- Review CERT@VDE advisory VDE-2025-014 and apply vendor-supplied firmware updates when available
- Audit site security controls, including enclosure locks and tamper detection, at deployed charging stations
Patch Information
Phoenix Contact and CERT@VDE have published advisory VDE-2025-014. Operators should consult the advisory for fixed firmware versions and apply updates to all affected CHARX SEC-3000, SEC-3050, SEC-3100, and SEC-3150 controllers.
Workarounds
- Physically block or disable the USB-C display connector where feasible
- Deploy tamper-evident seals on charging station enclosures to detect unauthorized access
- Limit public-facing access to maintenance ports through site design and signage
# No vendor-published configuration mitigation is available.
# Follow guidance in CERT@VDE advisory VDE-2025-014 for firmware updates
# and physical hardening of CHARX SEC-3000 series charging controllers.