CVE-2025-23374 Overview
CVE-2025-23374 affects Dell Networking Switches running Enterprise SONiC OS versions prior to 4.4.1 and 4.2.3. The flaw is classified as Insertion of Sensitive Information into Log File [CWE-532]. A remote attacker holding high privileges can read sensitive data written to log files, resulting in information exposure.
Dell published fixes in security advisory DSA-2025-057. The vulnerability requires authenticated network access and does not affect integrity or availability of the switch.
Critical Impact
Authenticated remote attackers can harvest sensitive information from Enterprise SONiC log files, potentially exposing credentials, tokens, or configuration data useful for lateral movement.
Affected Products
- Dell Enterprise SONiC Distribution versions prior to 4.4.1
- Dell Enterprise SONiC Distribution versions prior to 4.2.3
- Dell Networking Switches running the affected Enterprise SONiC OS releases
Discovery Timeline
- 2025-01-30 - CVE-2025-23374 published to NVD
- 2026-06-17 - Last updated in NVD database
Technical Details for CVE-2025-23374
Vulnerability Analysis
The vulnerability resides in logging routines within Dell Enterprise SONiC Distribution. Sensitive data that should be redacted or omitted is instead written to log files accessible to privileged users. An attacker with existing high-privilege access over the network can retrieve these logs and extract information not intended for routine administrative review.
Because the flaw only breaches confidentiality, system operations remain intact after exploitation. The exposed data, however, can accelerate follow-on attacks against the switch fabric, management plane, or connected infrastructure.
Root Cause
The root cause is improper handling of sensitive information in log output, mapped to [CWE-532]: Insertion of Sensitive Information into Log File. Logging code paths in affected SONiC releases do not strip or mask secrets before writing diagnostic records. Any principal with read access to those log files inherits visibility into the leaked content.
Attack Vector
Exploitation requires network reachability to the switch management interface and valid credentials with high privileges. The attacker authenticates to the SONiC management plane, navigates to logging facilities, and reads records that contain the exposed data. No user interaction is required, and the attack does not alter the device state.
Dell has not published a proof-of-concept, and no public exploit is available. See the Dell Security Update DSA-2025-057 for vendor technical details.
Detection Methods for CVE-2025-23374
Indicators of Compromise
- Unexpected access to SONiC log files or show logging command execution by accounts outside normal operations windows
- Log retrieval sessions originating from management IPs not associated with authorized administrators
- Export or copy operations targeting /var/log/ paths on SONiC switches
Detection Strategies
- Audit authentication events on the SONiC management plane for privileged logins preceding log access
- Correlate privileged CLI or REST API activity with log-read operations to identify reconnaissance patterns
- Review NetFlow or management-plane telemetry for SCP, SFTP, or rsync transfers of log archives off the switch
Monitoring Recommendations
- Forward SONiC syslog streams to a central SIEM and alert on bulk log retrieval by any account
- Enable command accounting (AAA) to record every privileged command issued on affected switches
- Baseline normal administrator behavior and alert on deviations such as off-hours log exports
How to Mitigate CVE-2025-23374
Immediate Actions Required
- Upgrade Dell Enterprise SONiC Distribution to version 4.4.1, 4.2.3, or later as specified in DSA-2025-057
- Rotate any credentials, API tokens, or secrets that may have been exposed through switch log files
- Restrict management-plane access to a dedicated out-of-band network with strict ACLs
- Review existing log archives for sensitive content and purge or sanitize before further distribution
Patch Information
Dell addressed CVE-2025-23374 in Enterprise SONiC Distribution versions 4.4.1 and 4.2.3. Full remediation details are available in the Dell Security Update DSA-2025-057. Operators should schedule the upgrade on all affected switches during the next maintenance window.
Workarounds
- Limit high-privilege accounts on SONiC switches to the minimum required set and enforce role-based access control
- Enforce multi-factor authentication on management-plane logins to raise the bar for privileged access abuse
- Restrict read access to log files and ship logs to an external collector where exposure can be managed centrally
- Monitor and alert on any privileged session that reads or exports local log files until patching is complete
# Configuration example
# Restrict SONiC management access to a trusted jump host subnet
sonic-cli# configure terminal
sonic-cli(config)# ip access-list MGMT-ACL
sonic-cli(config-ipv4-acl)# seq 10 permit tcp 10.10.0.0/24 any eq 22
sonic-cli(config-ipv4-acl)# seq 20 deny tcp any any eq 22
sonic-cli(config)# interface Management 0
sonic-cli(config-if-Management0)# ip access-group MGMT-ACL in
Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.