Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.
Sources: National Vulnerability Database, CISA KEV, Exploit-DB
CVE-2025-14910 Overview
CVE-2025-14910 is a path traversal vulnerability in the Edimax BR-6208AC wireless router running firmware version 1.02. The flaw resides in the handle_retr function of the FTP Daemon Service. An authenticated remote attacker can supply crafted paths to read files outside the intended FTP directory. The exploit technique is public. Edimax has confirmed the issue but will not release a patch, as the product has been discontinued for five years and is no longer supported. This vulnerability is classified under [CWE-22] (Improper Limitation of a Pathname to a Restricted Directory).
Critical Impact
Remote authenticated attackers can traverse the filesystem through the FTP RETR command to access files outside the intended directory on end-of-life Edimax BR-6208AC devices.
Affected Products
- Edimax BR-6208AC hardware version 2.0
- Edimax BR-6208AC firmware version 1.02
- Product line discontinued; no security patches will be issued
Discovery Timeline
- 2025-12-19 - CVE-2025-14910 published to NVD
- 2026-06-17 - Last updated in NVD database
Technical Details for CVE-2025-14910
Vulnerability Analysis
The vulnerability affects the FTP daemon shipped with the BR-6208AC router firmware. The handle_retr function processes the FTP RETR (retrieve file) command but fails to properly validate or sanitize the file path supplied by the client. An attacker with valid FTP credentials can submit path sequences containing ../ traversal characters. The daemon resolves these sequences against the underlying filesystem instead of restricting access to the intended FTP root. This allows read access to files outside the shared directory, including configuration or system files stored on the device.
Root Cause
The root cause is missing canonicalization and path validation in handle_retr. The function accepts user-controlled path strings and passes them to file-open routines without stripping traversal metacharacters or verifying that the resolved path remains within the FTP root. This is a classic instance of [CWE-22].
Attack Vector
Exploitation requires network reachability to the FTP service on the router and valid FTP credentials. Once authenticated, an attacker issues an FTP RETR command with a relative path containing traversal sequences to read arbitrary files accessible to the FTP daemon process. The attack can be executed remotely if the FTP service is exposed to untrusted networks.
No verified public exploit code is included here. Technical details are documented in the Notion Path Traversal Vulnerability writeup and in VulDB entry #337435.
Detection Methods for CVE-2025-14910
Indicators of Compromise
- FTP session logs containing RETR commands with ../ or encoded traversal sequences targeting the BR-6208AC.
- Successful FTP authentications from unexpected external IP addresses.
- Outbound transfers of files that reside outside the configured FTP share directory.
Detection Strategies
- Inspect FTP command traffic on port 21 for RETR requests containing traversal patterns such as ../, ..\, or URL-encoded equivalents.
- Correlate FTP authentication events with subsequent file retrieval commands referencing unusual paths.
- Alert on any FTP activity to or from the BR-6208AC management interface from untrusted networks.
Monitoring Recommendations
- Enable network flow logging at the gateway to identify FTP sessions to the affected router.
- Monitor for repeated failed login attempts followed by successful authentication, which may indicate credential brute forcing.
- Track configuration changes on the router that re-enable FTP after administrative disablement.
How to Mitigate CVE-2025-14910
Immediate Actions Required
- Disable the FTP service on the BR-6208AC through the device administration interface, as recommended by Edimax.
- Restrict management and FTP access to trusted internal networks using upstream firewall rules.
- Rotate any credentials that were configured on the FTP service.
- Plan replacement of the device with a currently supported model.
Patch Information
No patch will be released. Edimax has stated that the BR-6208AC has been discontinued for five years and no longer receives firmware updates or security patches. The vendor's mitigation guidance is to disable the FTP service and migrate to a supported product. Refer to the Edimax support advisory and VulDB #337435 for vendor communications.
Workarounds
- Disable the built-in FTP daemon; the router continues to function for standard routing and wireless use without it.
- Block inbound TCP/21 to the router at the network perimeter.
- Segment the router onto a management VLAN to limit exposure of the FTP service.
- Replace the end-of-life device with a supported model that receives security updates.
# Example: block inbound FTP to the router at an upstream firewall
iptables -I FORWARD -p tcp --dport 21 -d <router-ip> -j DROP