Skip to main content
CVE Vulnerability Database
Vulnerability Database/CVE-2025-14272

CVE-2025-14272: Pavilion Privilege Escalation Vulnerability

CVE-2025-14272 is a privilege escalation vulnerability in Pavilion caused by improper authorization in API endpoints. Attackers can execute admin operations including user and role management. This article covers technical details, affected versions, impact, and mitigation strategies.

Published:

CVE-2025-14272 Overview

CVE-2025-14272 is a missing authorization vulnerability [CWE-862] affecting Rockwell Automation Pavilion. The flaw stems from improper authorization enforcement in API endpoints. An unauthenticated network attacker can invoke privileged operations, including user and role management functions, without holding the required permissions. Successful exploitation grants administrative control over the affected application, enabling account creation, role modification, and other administrative actions reserved for trusted operators.

Critical Impact

Unauthenticated attackers can execute privileged API operations such as user and role management, leading to full administrative compromise of Pavilion deployments exposed to the network.

Affected Products

  • Rockwell Automation Pavilion (see vendor advisory SD1777 for affected versions)

Discovery Timeline

  • 2026-06-16 - CVE-2025-14272 published to the National Vulnerability Database (NVD)
  • 2026-06-17 - Last updated in NVD database

Technical Details for CVE-2025-14272

Vulnerability Analysis

The vulnerability is a broken access control issue in the Pavilion API layer. The application exposes administrative endpoints that fail to verify the caller's identity or role before executing the requested operation. As a result, the API trusts client-supplied requests to perform sensitive actions that should be gated by server-side authorization checks.

Because the attack vector is network-based and requires no authentication or user interaction, any actor able to reach the API surface can attempt exploitation. The flaw enables direct manipulation of identity primitives, including users and roles, which collapses the trust model of the application.

Root Cause

The root cause is missing or incomplete authorization enforcement on privileged API endpoints, classified under CWE-862 (Missing Authorization). The endpoints implement business logic for administrative functions but do not validate that the caller possesses the necessary privileges before executing the operation. Authentication state and role membership are not checked at the function level.

Attack Vector

An attacker reaches the Pavilion API over the network and issues crafted HTTP requests to administrative endpoints responsible for user and role management. Because the server does not enforce authorization, the requests execute with administrative effect. Refer to the Rockwell Automation Security Advisory SD1777 for vendor-confirmed technical details.

No public proof-of-concept exploit is available at the time of publication, and the issue is not listed in the CISA Known Exploited Vulnerabilities catalog.

Detection Methods for CVE-2025-14272

Indicators of Compromise

  • Unexpected user accounts or role assignments created or modified within Pavilion administrative records.
  • API requests to user or role management endpoints originating from source addresses that have not previously authenticated as administrators.
  • Audit log gaps or entries that show privileged actions without an associated administrator session identifier.

Detection Strategies

  • Inspect Pavilion application and web server logs for HTTP requests targeting administrative API paths from non-administrative clients.
  • Correlate identity-store changes (user creation, role assignment) with authentication events to identify privileged actions performed without a valid admin session.
  • Deploy network monitoring rules that flag unauthenticated access attempts to Pavilion API endpoints from outside expected management subnets.

Monitoring Recommendations

  • Forward Pavilion API logs, authentication events, and audit trails into a centralized SIEM for correlation across identity and network telemetry.
  • Establish a baseline of normal administrative activity and alert on deviations in request volume, source, or endpoint usage.
  • Monitor for lateral movement and post-compromise behavior on hosts reachable from the Pavilion environment.

How to Mitigate CVE-2025-14272

Immediate Actions Required

  • Apply the fixed version identified in the Rockwell Automation Security Advisory SD1777 as soon as it is available in your environment.
  • Restrict network access to Pavilion API endpoints to trusted management networks using firewall and segmentation controls.
  • Audit existing Pavilion user accounts and role assignments for unauthorized changes and revoke any anomalous entries.

Patch Information

Rockwell Automation has published advisory SD1777 describing remediation guidance for CVE-2025-14272. Administrators should consult the advisory for the specific fixed build, upgrade procedure, and any required configuration changes. The advisory is available at the Rockwell Automation Trust Center.

Workarounds

  • Place Pavilion behind a reverse proxy or API gateway that enforces authentication and authorization before requests reach the application.
  • Limit exposure of the management interface to dedicated administrative VLANs and require VPN access for remote administrators.
  • Disable or block administrative API endpoints from external networks until the vendor patch can be applied.

Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.

Default Legacy - Prefooter | Experience the World’s Most Advanced Cybersecurity Platform

Experience the Most Advanced Cybersecurity Platform

See how the world’s most intelligent, autonomous cybersecurity platform can protect your organization today and into the future.