CVE-2025-0816 Overview

CVE-2025-0816 is an improper input validation vulnerability [CWE-20] disclosed by Schneider Electric. An attacker on an adjacent network can send crafted IPv6 packets to the affected device, triggering a Denial-of-Service (DoS) condition. The flaw does not affect confidentiality or integrity but can disrupt availability of the targeted equipment. Schneider Electric documented the issue in security notice SEVD-2025-042-04.

Critical Impact

Malicious IPv6 packets sent from the adjacent network can force the affected Schneider Electric product into a Denial-of-Service state, interrupting operational availability.

Affected Products

  • Schneider Electric product(s) listed in advisory SEVD-2025-042-04
  • Devices processing IPv6 traffic on the affected firmware
  • Refer to the vendor advisory for the complete model and firmware matrix

Discovery Timeline

  • 2025-02-13 - CVE CVE-2025-0816 published to NVD
  • 2026-06-17 - Last updated in NVD database

Technical Details for CVE-2025-0816

Vulnerability Analysis

The vulnerability stems from improper validation of inbound IPv6 packets on the affected Schneider Electric device. When the device parses a specifically crafted IPv6 frame, internal input validation fails to reject malformed field values. This failure leads the networking stack into an unrecoverable state and halts normal processing. The result is a Denial-of-Service condition that disrupts the device's intended operation.

Because this is an Operational Technology (OT) component, an availability loss can cascade into process interruption and loss of monitoring or control. The attack targets availability only; no code execution or data disclosure is indicated in the advisory. Recovery typically requires a restart of the affected device.

Root Cause

The root cause is improper input validation [CWE-20] in the IPv6 packet handling path. The device accepts packet structures that should be rejected during parsing. Malformed or unexpected field values are not sanitized before they reach downstream processing logic.

Attack Vector

Exploitation requires network adjacency, meaning the attacker must reach the device over the same layer-2 or routed IPv6 segment. No authentication and no user interaction are required. An attacker who has already gained a foothold on a shared OT or management network can send malicious IPv6 packets to the device and trigger the DoS. See the Schneider Electric Security Notice SEVD-2025-042-04 for the authoritative technical description.

Detection Methods for CVE-2025-0816

Indicators of Compromise

  • Unexpected restarts, watchdog resets, or loss of communication from affected Schneider Electric devices
  • Sudden absence of SCADA or process-control telemetry from the device
  • Bursts of malformed IPv6 traffic directed at the device's management interface

Detection Strategies

  • Deploy an OT-aware intrusion detection system to inspect IPv6 traffic for malformed extension headers and anomalous field values
  • Baseline normal IPv6 traffic patterns to and from control-system devices and alert on deviations
  • Correlate device availability events with network capture data to identify triggering packets

Monitoring Recommendations

  • Monitor IPv6 packet rates and malformed-packet counters on switches and firewalls facing OT segments
  • Alert on repeated device reboots or loss of heartbeat signals from Schneider Electric equipment
  • Capture full-packet traces at ingress points to control networks for post-incident analysis

How to Mitigate CVE-2025-0816

Immediate Actions Required

  • Review the Schneider Electric advisory SEVD-2025-042-04 and identify affected firmware versions in the environment
  • Apply vendor-provided firmware updates once available for the identified devices
  • Restrict IPv6 traffic to affected devices through firewall and VLAN segmentation
  • Place affected equipment behind an OT firewall that filters malformed IPv6 packets

Patch Information

Schneider Electric has published remediation guidance in Security Notice SEVD-2025-042-04. Apply the firmware version specified in the notice for each affected product line. Validate the update in a staging environment before deploying to production control systems.

Workarounds

  • Disable IPv6 on the affected device if the operational environment does not require it
  • Enforce strict allow-lists on upstream firewalls so only trusted hosts can reach the device's IPv6 interface
  • Segment OT networks from corporate and remote-access networks to shrink the adjacent attack surface
  • Monitor device reachability continuously so that any DoS event is detected and remediated promptly
bash
# Example: restrict inbound IPv6 to a Schneider Electric device using ip6tables
# Allow IPv6 only from a defined management host and drop everything else
ip6tables -A FORWARD -s 2001:db8:ot::10 -d 2001:db8:plc::5 -j ACCEPT
ip6tables -A FORWARD -d 2001:db8:plc::5 -j DROP

Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.

Sources: National Vulnerability Database, CISA KEV, Exploit-DB

Experience the Most Advanced Cybersecurity Platform

See how the world’s most intelligent, autonomous cybersecurity platform can protect your organization today and into the future.