CVE-2024-8306 Overview
CVE-2024-8306 is an improper privilege management flaw [CWE-269] affecting Schneider Electric Vijeo Designer and Vijeo Designer embedded in EcoStruxure Machine Expert. A non-administrative authenticated user can tamper with product binaries to escalate privileges on the workstation. Successful exploitation results in unauthorized access and loss of confidentiality, integrity, and availability on the affected host. The vulnerability is local to the workstation and does not require user interaction once the attacker holds a low-privileged account. Schneider Electric published advisory SEVD-2024-254-01 describing the issue and remediation.
Critical Impact
An authenticated local user can replace or modify Vijeo Designer binaries to execute code with elevated privileges, fully compromising the engineering workstation used to program industrial control systems.
Affected Products
- Schneider Electric Vijeo Designer (including version 6.3)
- Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert
- Engineering workstations running the above software for HMI and PLC programming
Discovery Timeline
- 2024-09-11 - CVE-2024-8306 published to the National Vulnerability Database
- 2024-09-11 - Schneider Electric released security notice SEVD-2024-254-01
- 2026-06-17 - Last updated in NVD database
Technical Details for CVE-2024-8306
Vulnerability Analysis
The vulnerability is categorized as improper privilege management [CWE-269] within the Vijeo Designer installation. Vijeo Designer is a human-machine interface (HMI) configuration suite distributed standalone and bundled inside EcoStruxure Machine Expert. The product installs executables and supporting files that run or are invoked with privileges higher than those of the interactive user. Because the installed binaries are not sufficiently protected against modification by non-administrative accounts, a local authenticated user can replace a trusted binary with attacker-controlled code. When the modified binary is subsequently executed by a privileged context, the attacker code inherits those privileges. The outcome is a full local privilege escalation on the engineering workstation, with downstream risk to any PLC or HMI projects stored or deployed from that host.
Root Cause
The root cause is weak access control on files or directories belonging to the Vijeo Designer installation. Non-administrative users retain write access to binaries or paths that are later executed by a higher-privileged process or scheduled task. This permission model violates the principle of least privilege and enables tampering with trusted executables.
Attack Vector
Exploitation requires local access with a valid low-privileged account on the workstation. The attacker identifies a Vijeo Designer binary writable by their user context, replaces or patches it with malicious code, and waits for the binary to be invoked by a privileged process, service, or administrator. No network access or user interaction with crafted content is required beyond the normal operation of the software.
No verified public proof-of-concept exploit is available. See the Schneider Electric Security Notice SEVD-2024-254-01 for vendor technical details.
Detection Methods for CVE-2024-8306
Indicators of Compromise
- Unexpected modifications to executables, DLLs, or configuration files inside the Vijeo Designer or EcoStruxure Machine Expert installation directories.
- File hashes for Vijeo Designer binaries that do not match the vendor-published values after installation or patching.
- New or modified scheduled tasks, services, or auto-start entries that reference Vijeo Designer paths.
- Process creation events where a Vijeo Designer binary spawns an unexpected child such as cmd.exe, powershell.exe, or rundll32.exe.
Detection Strategies
- Enable file integrity monitoring on the Vijeo Designer and EcoStruxure Machine Expert installation directories and alert on writes by non-administrative accounts.
- Audit NTFS permissions on installation folders and flag any directory where the Users or Authenticated Users group holds Modify or Write access to executables.
- Correlate Windows Security event ID 4663 (object access) with event ID 4688 (process creation) to detect binary replacement followed by privileged execution.
Monitoring Recommendations
- Baseline hashes of all Vijeo Designer binaries after installation and re-verify after each vendor update.
- Forward endpoint telemetry from engineering workstations to a central SIEM or data lake for retention and hunting.
- Review privileged account logons on OT engineering hosts and investigate any process launched from a user-writable path.
How to Mitigate CVE-2024-8306
Immediate Actions Required
- Apply the Schneider Electric remediation documented in advisory SEVD-2024-254-01 to all affected Vijeo Designer and EcoStruxure Machine Expert installations.
- Restrict interactive logon on engineering workstations to administrators and designated OT engineers only.
- Remove Modify and Write permissions for non-administrative users on the Vijeo Designer installation directory and its subfolders.
- Inventory every workstation running Vijeo Designer, including instances embedded in EcoStruxure Machine Expert, and prioritize patching based on exposure.
Patch Information
Schneider Electric published remediation guidance in the Schneider Electric Security Notice SEVD-2024-254-01. Administrators should obtain the fixed version from the Schneider Electric customer portal and validate the installation against vendor-published hashes.
Workarounds
- Where immediate patching is not possible, manually tighten access control lists on the Vijeo Designer installation path so only SYSTEM and Administrators can write.
- Enforce application allowlisting (for example, Windows Defender Application Control or AppLocker) to block execution of modified binaries.
- Isolate engineering workstations on a dedicated OT network segment and disable shared local accounts.
- Monitor the host with endpoint detection tooling and investigate any privilege escalation attempts originating from Vijeo Designer processes.
# Example: restrict write access on the Vijeo Designer install directory (Windows, run as Administrator)
icacls "C:\Program Files (x86)\Schneider Electric\Vijeo-Designer" /inheritance:r
icacls "C:\Program Files (x86)\Schneider Electric\Vijeo-Designer" /grant:r "SYSTEM:(OI)(CI)F" "Administrators:(OI)(CI)F" "Users:(OI)(CI)RX"