CVE-2024-7517 Overview

CVE-2024-7517 is a command injection vulnerability [CWE-78] in Broadcom Brocade Fabric Operating System (FOS). The flaw affects versions prior to 9.2.0c and versions 9.2.1 through 9.2.1a on IP Extension platforms. A locally authenticated attacker can escalate privileges through crafted use of the portcfg command.

Exploitation is limited to specific hardware: Brocade 7810, 7840, 7850, and X6 or X7 directors equipped with an SX-6 Extension blade. The attacker must access the switch through SSH or serial console before conducting the attack.

Critical Impact

Successful exploitation grants privileged shell access on IP Extension platforms, allowing attackers to compromise fabric configuration, intercept replicated storage traffic, and pivot across the storage network.

Affected Products

  • Broadcom Brocade Fabric OS versions before 9.2.0c
  • Broadcom Brocade Fabric OS versions 9.2.1 through 9.2.1a
  • IP Extension platforms: Brocade 7810, 7840, 7850, and X6/X7 directors with SX-6 Extension blade

Discovery Timeline

  • 2024-11-21 - CVE-2024-7517 published to the National Vulnerability Database (NVD)
  • 2026-06-17 - Last updated in NVD database

Technical Details for CVE-2024-7517

Vulnerability Analysis

The vulnerability resides in the portcfg command handler within Brocade Fabric OS. The command accepts user-supplied parameters that are passed to an underlying OS shell without adequate sanitization. An authenticated user with standard CLI access can inject shell metacharacters that execute with elevated privileges.

Command injection flaws classified under [CWE-78] arise when applications construct OS commands using untrusted input. In this case, the FOS management CLI runs portions of configuration logic as a privileged account. Injected commands inherit those elevated rights.

The scope is restricted to IP Extension functionality, which is only present on the Brocade 7810, 7840, 7850, and SX-6 blades. Pure Fibre Channel switches without IP Extension capability are not exposed.

Root Cause

The root cause is improper neutralization of special elements inside the portcfg command parser. Argument strings reach a system execution function with shell metacharacters intact. The handler executes under a higher privilege context than the invoking CLI user.

Attack Vector

The attack vector is local. An attacker must first authenticate to the switch over SSH or a serial console session using valid credentials. After login, the attacker issues a crafted portcfg command sequence that embeds shell operators, chaining additional commands onto the invocation.

The injected commands execute at the elevated privilege level used by the configuration subsystem. This yields administrative control over the switch, bypassing role-based access controls that normally restrict standard operator accounts.

No exploit code or proof-of-concept has been published for CVE-2024-7517. Refer to the Broadcom Security Advisory #25071 for vendor technical details.

Detection Methods for CVE-2024-7517

Indicators of Compromise

  • Unexpected portcfg invocations containing shell metacharacters such as ;, |, &, `, or $() in CLI audit logs
  • New or modified administrative accounts, SSH keys, or configuration changes made outside approved change windows
  • Shell command execution logged under service accounts that normally only run FOS management functions
  • Unexpected outbound network connections from the switch management interface

Detection Strategies

  • Forward Fabric OS syslog and CLI audit records to a centralized SIEM and alert on anomalous portcfg argument patterns
  • Baseline normal administrative command usage per operator and flag deviations such as metacharacter sequences
  • Correlate SSH and serial console session metadata with privilege-sensitive command execution

Monitoring Recommendations

  • Enable verbose command auditing on all affected Brocade IP Extension platforms and ship logs off-box
  • Monitor administrative session frequency, source IP ranges, and session duration for unauthorized access
  • Review account inventories on Fabric OS switches on a recurring basis to identify unauthorized credentials

How to Mitigate CVE-2024-7517

Immediate Actions Required

  • Identify all Brocade 7810, 7840, 7850, and X6/X7 directors with SX-6 blades in the environment and inventory FOS versions
  • Restrict SSH and serial console access to the switch management plane using jump hosts and strict ACLs
  • Rotate credentials and audit role assignments for all FOS user accounts, removing unused or shared accounts
  • Review recent CLI audit logs on affected switches for suspicious portcfg usage

Patch Information

Broadcom addressed CVE-2024-7517 in Fabric OS version 9.2.0c and later, and in versions after 9.2.1a. Administrators should upgrade affected IP Extension platforms to a fixed release. Full remediation guidance is published in the Broadcom Security Advisory #25071.

Workarounds

  • Limit interactive CLI access on affected switches to a minimal set of trusted administrators until patches are deployed
  • Enforce multi-factor authentication on the bastion or jump host used to reach the switch management interface
  • Segment the management network so that only authorized administrative workstations can reach SSH on Fabric OS devices
  • Disable or restrict unused accounts and ensure serial console access requires physical security controls
bash
# Configuration example: restrict SSH management access via ACL on Fabric OS
ipfilter --create mgmt_acl -type ipv4
ipfilter --addrule mgmt_acl -seq 1 -act permit -proto tcp -dp 22 -sip 10.10.0.0/24
ipfilter --addrule mgmt_acl -seq 2 -act deny  -proto tcp -dp 22 -sip 0.0.0.0/0
ipfilter --activate mgmt_acl