Skip to main content
Vulnerability Database/CVE-2024-47904

CVE-2024-47904: Siemens InterMesh Privilege Escalation

CVE-2024-47904 is a privilege escalation vulnerability in Siemens InterMesh 7177 Hybrid 2.0 Subscriber that allows authenticated local attackers to execute commands with root privileges through a SUID binary flaw. This article covers technical details, affected versions, impact assessment, and mitigation strategies.

Published:

Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.

Sources: National Vulnerability Database, CISA KEV, Exploit-DB

CVE-2024-47904 Overview

CVE-2024-47904 is a local privilege escalation vulnerability affecting Siemens InterMesh 7177 Hybrid 2.0 Subscriber and InterMesh 7707 Fire Subscriber devices. The affected firmware ships with a Set User ID (SUID) binary that permits an authenticated local attacker to execute arbitrary commands with root privileges. The flaw is categorized under [CWE-266: Incorrect Privilege Assignment]. Siemens published advisory SSA-333468 to coordinate remediation. The InterMesh 7707 Fire Subscriber is only exposed when the non-default IP interface is enabled.

Critical Impact

An authenticated local attacker can abuse a misconfigured SUID binary to gain full root control of affected InterMesh subscriber devices, compromising confidentiality, integrity, and availability of the firmware.

Affected Products

  • Siemens InterMesh 7177 Hybrid 2.0 Subscriber (all versions prior to V8.2.12)
  • Siemens InterMesh 7707 Fire Subscriber (all versions prior to V7.2.12, only when IP interface is enabled)
  • Siemens InterMesh 7707 Fire Subscriber firmware

Discovery Timeline

  • 2024-10-23 - CVE-2024-47904 published to the National Vulnerability Database
  • 2026-06-17 - Last updated in NVD database

Technical Details for CVE-2024-47904

Vulnerability Analysis

The vulnerability stems from an SUID-marked executable included in the InterMesh subscriber firmware. SUID binaries execute with the privileges of the file owner rather than the invoking user. When the owner is root, any flaw in how the binary handles input, environment, or child processes can be leveraged to escalate privileges. In this case the binary allows an authenticated local user to execute arbitrary commands as root, bypassing the device's privilege boundary.

Successful exploitation yields complete control over the device firmware. An attacker can modify system configuration, extract cryptographic material, install persistence, or disrupt fire alarm signaling on the 7707 Fire Subscriber. Because InterMesh devices operate in safety-critical paging and alerting networks, root access on a subscriber node undermines the integrity of downstream alarm dispatching.

Root Cause

The root cause is incorrect privilege assignment [CWE-266] on a shipped binary. The SUID bit grants elevated execution rights without a corresponding input validation or privilege-dropping routine inside the binary itself. Any functionality within the executable that spawns subprocesses, invokes a shell, or evaluates user-controlled arguments runs with root authority.

Attack Vector

Exploitation requires local access and valid low-privileged credentials on the device. Network exposure is limited to the 7707 Fire Subscriber only when the optional IP interface is enabled, which is not the default configuration. No user interaction is required. The attacker invokes the vulnerable SUID binary with crafted parameters to execute arbitrary commands under the root account. Technical reproduction details are not published; refer to the Siemens Security Advisory SSA-333468 for vendor-provided context.

Detection Methods for CVE-2024-47904

Indicators of Compromise

  • Unexpected processes running as uid=0 that were spawned by non-root user sessions on InterMesh subscriber devices.
  • Modifications to firmware configuration files, startup scripts, or newly created files owned by root in user-writable paths.
  • Audit log entries showing invocation of SUID binaries by low-privileged accounts followed by privileged system changes.

Detection Strategies

  • Inventory firmware versions across InterMesh 7177 Hybrid 2.0 and 7707 Fire Subscriber deployments and flag any device running a version below V8.2.12 or V7.2.12 respectively.
  • Enumerate SUID binaries on affected devices using find / -perm -4000 -type f during maintenance windows and compare against a known-good baseline.
  • Correlate local authentication events with subsequent root-level process execution to identify abuse of the privileged binary.

Monitoring Recommendations

  • Forward device syslog and shell audit records to a centralized SIEM for retention and correlation.
  • Alert on configuration drift and unexpected service restarts on InterMesh subscriber nodes.
  • Monitor whether the optional IP interface is enabled on 7707 Fire Subscriber devices and alert on activation.

How to Mitigate CVE-2024-47904

Immediate Actions Required

  • Upgrade InterMesh 7177 Hybrid 2.0 Subscriber firmware to V8.2.12 or later.
  • Upgrade InterMesh 7707 Fire Subscriber firmware to V7.2.12 or later.
  • Restrict and audit local account access on affected devices; rotate credentials for accounts that could reach a shell on the subscriber.
  • Review the Siemens Security Advisory SSA-333468 for vendor-specific remediation guidance.

Patch Information

Siemens addressed CVE-2024-47904 in InterMesh 7177 Hybrid 2.0 Subscriber firmware version V8.2.12 and InterMesh 7707 Fire Subscriber firmware version V7.2.12. Apply vendor-signed firmware updates through the standard Siemens update procedure. Validate firmware integrity after upgrade and confirm the vulnerable SUID binary is replaced or hardened.

Workarounds

  • On InterMesh 7707 Fire Subscriber devices, disable the IP interface if it is not operationally required; this removes the network-exposed path to the device shell.
  • Limit physical and console access to subscriber hardware to authorized personnel only.
  • Enforce the principle of least privilege for any local service accounts on the devices and remove unused accounts.

Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.

Sources: National Vulnerability Database, CISA KEV, Exploit-DB

Experience the Most Advanced Cybersecurity Platform

See how the world’s most intelligent, autonomous cybersecurity platform can protect your organization today and into the future.