CVE-2024-47783 is a privilege escalation vulnerability in Siemens Siport caused by improper file permissions. Local attackers can exploit this to gain elevated privileges by modifying service executables. This article covers technical details, affected versions, impact assessment, and mitigation strategies.

Published:

Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.

Sources: National Vulnerability Database, CISA KEV, Exploit-DB

CVE-2024-47783 Overview

CVE-2024-47783 is a local privilege escalation vulnerability in Siemens SIPORT, affecting all versions prior to V3.4.0. The application improperly assigns file permissions to its installation folders. A local attacker with an unprivileged account can replace or modify service executables stored in those folders. When the SIPORT service subsequently runs the tampered binary under a higher-privileged account, the attacker gains elevated privileges on the host. The flaw maps to CWE-732: Incorrect Permission Assignment for Critical Resource and is documented in Siemens Security Advisory SSA-064257.

Critical Impact

An authenticated local user can overwrite SIPORT service binaries to execute arbitrary code with service-level privileges, compromising confidentiality, integrity, and availability of the host.

Affected Products

  • Siemens SIPORT, all versions earlier than V3.4.0
  • Windows hosts running the SIPORT access management service
  • Deployments where unprivileged users have interactive logon access to SIPORT systems

Discovery Timeline

  • 2024-11-12 - CVE-2024-47783 published to NVD
  • 2026-06-17 - Last updated in NVD database

Technical Details for CVE-2024-47783

Vulnerability Analysis

SIPORT is Siemens' access control and time management software. During installation, the product applies permissive access control lists (ACLs) to its installation directories. These directories contain the executables and supporting libraries loaded by the SIPORT Windows service, which runs with elevated privileges.

Because unprivileged local users retain write access to these directories, they can replace legitimate service binaries with attacker-controlled payloads. When the service restarts, Windows executes the planted binary in the service account context. This yields a reliable local privilege escalation path. The weakness is classified as CWE-732: Incorrect Permission Assignment for Critical Resource.

Root Cause

The root cause is an insecure default permission assignment during installation. The installer does not restrict write and modify access to the SIPORT program directory to administrative principals. Non-administrative users inherit permissions that allow modification of files the service later loads at startup.

Attack Vector

Exploitation requires local access and low privileges, with no user interaction. An attacker with an interactive or remote shell session as an unprivileged user enumerates the SIPORT installation path, confirms write access, and overwrites a service executable or a DLL that the service loads. The attacker then triggers a service restart or waits for a system reboot. The service starts the tampered binary under its configured account, delivering code execution at that privilege level.

No public proof-of-concept, exploit module, or in-the-wild exploitation has been reported. CISA has not added CVE-2024-47783 to the Known Exploited Vulnerabilities catalog.

Detection Methods for CVE-2024-47783

Indicators of Compromise

  • Unexpected modification timestamps on executables or DLLs within the SIPORT installation directory
  • SIPORT service binaries with hashes that do not match the vendor-signed baseline
  • Unsigned or unexpectedly signed executables replacing original SIPORT components
  • SIPORT service processes spawning cmd.exe, powershell.exe, or other interactive shells

Detection Strategies

  • Baseline file integrity for the SIPORT program directory and alert on changes to .exe and .dll files outside patch windows
  • Monitor Windows Service Control Manager events (Event ID 7036, 7045) for anomalous SIPORT service restarts initiated by non-administrative accounts
  • Audit NTFS ACLs on the SIPORT installation path to identify directories granting write access to Users or Authenticated Users
  • Correlate process creation events where the SIPORT service account spawns child processes atypical for the application

Monitoring Recommendations

  • Enable Windows object access auditing on the SIPORT installation folder and forward events to a centralized log platform
  • Track service binary path integrity using endpoint detection tooling with behavioral analytics
  • Review scheduled tasks and autoruns tied to SIPORT components for unauthorized modifications

How to Mitigate CVE-2024-47783

Immediate Actions Required

  • Upgrade SIPORT to version V3.4.0 or later as directed in Siemens Security Advisory SSA-064257
  • Inventory all SIPORT installations and prioritize hosts where unprivileged users can log on locally
  • Harden NTFS permissions on the SIPORT installation directory to restrict write access to administrators and the service account
  • Validate the integrity of existing SIPORT binaries against vendor-provided hashes before patching

Patch Information

Siemens addressed CVE-2024-47783 in SIPORT V3.4.0. Administrators should download the fixed release from Siemens Industry Online Support and follow the upgrade guidance in Siemens Security Advisory SSA-064257. After upgrading, verify that installation directory ACLs no longer grant write permissions to standard users.

Workarounds

  • Restrict interactive and remote logon rights on SIPORT hosts to trusted administrative personnel until patching is complete
  • Manually tighten ACLs on the SIPORT installation directory so only SYSTEM, Administrators, and the service account have modify rights
  • Apply application allowlisting to block execution of unsigned or unexpected binaries from the SIPORT program path
bash
# Example: audit and remediate ACLs on the SIPORT installation directory (Windows)
icacls "C:\Program Files\Siemens\SIPORT"
icacls "C:\Program Files\Siemens\SIPORT" /inheritance:r
icacls "C:\Program Files\Siemens\SIPORT" /grant:r "SYSTEM:(OI)(CI)F" "Administrators:(OI)(CI)F"
icacls "C:\Program Files\Siemens\SIPORT" /remove "Users" "Authenticated Users"