Skip to main content
Vulnerability Database/CVE-2024-46886

CVE-2024-46886: Web Server CSRF Redirection Vulnerability

CVE-2024-46886 is a CSRF vulnerability in web server software that enables attackers to redirect users to malicious URLs through crafted links. This article covers the technical details, exploitation methods, and mitigation strategies.

Published:

Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.

Sources: National Vulnerability Database, CISA KEV, Exploit-DB

CVE-2024-46886 Overview

CVE-2024-46886 is an open redirect vulnerability affecting the web server of certain Siemens devices. The web server fails to properly validate input used in user redirection logic. An attacker can craft a malicious URL that causes the server to redirect an authenticated or legitimate user to an attacker-chosen destination. Successful exploitation requires user interaction, as the victim must click the attacker-crafted link. The flaw is tracked under CWE-601: URL Redirection to Untrusted Site and was published to the National Vulnerability Database (NVD) on October 8, 2024.

Critical Impact

Attackers can leverage the trusted Siemens domain to redirect users to phishing or malware-hosting sites, enabling credential theft and social-engineering campaigns.

Affected Products

  • Siemens industrial devices with embedded web server (see Siemens advisory SSA-876787 for the specific product list and firmware versions)
  • Refer to the vendor advisory for exact affected models and firmware ranges
  • Specific CPE identifiers are not published in NVD at this time

Discovery Timeline

  • 2024-10-08 - CVE-2024-46886 published to NVD alongside Siemens Security Advisory SSA-876787
  • 2026-06-17 - Last updated in NVD database

Technical Details for CVE-2024-46886

Vulnerability Analysis

The vulnerability resides in the HTTP redirection handling of the affected Siemens web server. The server accepts a user-controlled parameter that specifies a redirect target. It does not validate whether the target points to a trusted domain or path. An attacker who constructs a URL pointing to the vulnerable endpoint can embed an arbitrary external destination. When the victim clicks the link, the server issues an HTTP redirect to the attacker-controlled URL.

Because the initial URL originates from a trusted Siemens device, URL inspection by users and some security tooling may fail to flag the request. The redirect effectively launders attacker URLs through the legitimate host.

Root Cause

The root cause is improper input validation of a redirection parameter processed by the web server, categorized as CWE-601. The server trusts the supplied value and uses it directly in the Location response header without enforcing an allowlist of permitted targets or verifying that the destination matches the server's own origin.

Attack Vector

Exploitation is network-based and requires user interaction. An attacker crafts a URL referencing the vulnerable endpoint on the Siemens device with a redirect parameter that points to an external attacker-controlled site. The attacker distributes the link through email, chat, or malicious web pages. When the user clicks the link, the web server responds with an HTTP redirect to the attacker's destination, which can serve a phishing page impersonating the device login portal or deliver malicious content.

No authentication or elevated privileges are required to initiate the attack. The impact is limited to integrity of the redirection flow and does not expose device data directly, but it enables downstream credential theft against operators of the device.

Technical details are described in prose only; no verified public proof-of-concept code is referenced. See the Siemens Security Advisory SSA-876787 for additional context.

Detection Methods for CVE-2024-46886

Indicators of Compromise

  • HTTP requests to the device web server containing redirect parameters with external absolute URLs (schemes such as http:// or https:// pointing outside the device origin)
  • Server responses with HTTP 302 or HTTP 301 status codes where the Location header points to a non-device domain
  • Access logs showing clicks on crafted URLs delivered via phishing campaigns targeting operations personnel

Detection Strategies

  • Inspect web server access logs for query parameters that contain fully qualified URLs or encoded URL schemes
  • Correlate outbound redirects from Siemens device hosts to uncommon external domains, especially newly registered domains
  • Flag user-agent patterns and referer chains that indicate link-based delivery from external sources

Monitoring Recommendations

  • Enable centralized logging for the device web server and forward logs to a security information and event management (SIEM) platform for analysis
  • Monitor DNS and proxy telemetry for traffic flows initiated from redirects originating at known device management URLs
  • Alert on repeated redirect responses from engineering or operations workstations within short time windows

How to Mitigate CVE-2024-46886

Immediate Actions Required

  • Review Siemens Security Advisory SSA-876787 and apply the firmware update listed for your affected product
  • Restrict access to the device web server to trusted management networks using network segmentation and firewall rules
  • Educate operations and engineering staff on recognizing suspicious URLs that reference internal device hostnames with embedded redirect parameters

Patch Information

Siemens published fix guidance in advisory SSA-876787. Administrators should consult the advisory for the specific firmware versions that address CVE-2024-46886 and follow the vendor's update procedure for the affected product family. Where a fixed version is not yet available for a given product, apply the workarounds listed in the advisory.

Workarounds

  • Place affected devices behind a VPN or jump host so the web server is not reachable from untrusted networks
  • Block outbound internet access from workstations that routinely access the device management interface, limiting phishing redirect effectiveness
  • Use a web proxy with URL filtering to inspect and block redirects from device hostnames to external destinations
  • Follow Siemens' Operational Guidelines for Industrial Security to harden the overall environment

Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.

Sources: National Vulnerability Database, CISA KEV, Exploit-DB

Experience the Most Advanced Cybersecurity Platform

See how the world’s most intelligent, autonomous cybersecurity platform can protect your organization today and into the future.