Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.
Sources: National Vulnerability Database, CISA KEV, Exploit-DB
CVE-2024-45710 Overview
CVE-2024-45710 is a local privilege escalation vulnerability in the SolarWinds Platform caused by an uncontrolled search path element [CWE-427]. An authenticated attacker with a low-privileged local account on an affected node can place a malicious binary or library in a directory searched by a privileged SolarWinds process. When the process loads the attacker-controlled file, code executes with elevated privileges.
Critical Impact
A low-privileged local user can escalate to the privileges of the SolarWinds service account, gaining full confidentiality, integrity, and availability impact on the host.
Affected Products
- SolarWinds Platform (see vendor advisory for fixed version)
- Deployments running on Windows nodes where the SolarWinds Platform services execute
- Any environment where low-privileged users have local shell or file-write access to the SolarWinds node
Discovery Timeline
- 2024-10-16 - CVE-2024-45710 published to the National Vulnerability Database
- 2026-06-17 - Last updated in the NVD database
Technical Details for CVE-2024-45710
Vulnerability Analysis
The flaw is classified as an Uncontrolled Search Path Element weakness. A privileged SolarWinds Platform process resolves one or more executables, dynamic link libraries (DLLs), or supporting files using a search path that includes directories writable by low-privileged users. When the process starts or dynamically loads a dependency, Windows walks the search order and loads the first matching file. An attacker who plants a crafted file earlier in that order causes the privileged process to execute attacker code.
Exploitation requires a valid low-privileged account and local access to the SolarWinds node. User interaction is not required. Successful exploitation yields code execution in the context of the SolarWinds service account, which typically holds elevated or SYSTEM-level rights on the host.
Root Cause
The root cause is improper control over the search path used to resolve a loadable component (CWE-427). The affected process either uses relative paths, inherits an untrusted PATH, or searches a directory with weak Access Control List (ACL) permissions before searching trusted system locations. SolarWinds does not disclose the specific binary in the public advisory; refer to the vendor security bulletin for full component details.
Attack Vector
The attack vector is local. A low-privileged user drops a malicious DLL or executable with a name matching one expected by the SolarWinds Platform into a directory on the search path. When the privileged service is restarted, triggered, or performs its scheduled load, it executes the planted payload. The result is privilege escalation on the affected node.
No verified public proof-of-concept is available for this CVE. See the SolarWinds Security Advisory CVE-2024-45710 for component-specific technical details.
Detection Methods for CVE-2024-45710
Indicators of Compromise
- Unexpected .dll or .exe files written to SolarWinds installation directories or directories listed in the service PATH by non-administrative users
- SolarWinds Platform service processes loading modules from non-standard directories such as user profile paths or temporary folders
- New child processes spawned by SolarWinds services running under the SolarWinds service account shortly after a file-write event in a search path directory
Detection Strategies
- Enable Windows Sysmon Event ID 7 (Image Loaded) to identify DLLs loaded by SolarWinds processes from unexpected paths
- Audit filesystem writes to SolarWinds Platform directories using Windows Event ID 4663 with Security Access Control Lists (SACLs) applied
- Correlate low-privileged user file-write events with subsequent SolarWinds service restart or module load events
Monitoring Recommendations
- Monitor process ancestry for SolarWinds services spawning unexpected children such as cmd.exe, powershell.exe, or rundll32.exe
- Alert on modifications to the system or service PATH environment variable on hosts running the SolarWinds Platform
- Track service account logon activity for anomalous interactive sessions originating from the SolarWinds node
How to Mitigate CVE-2024-45710
Immediate Actions Required
- Apply the SolarWinds Platform update referenced in the vendor advisory to the latest patched release
- Restrict local logon rights on SolarWinds nodes to administrators and required service accounts only
- Audit and tighten ACLs on all directories listed in the SolarWinds service PATH to deny write access for non-administrative users
Patch Information
SolarWinds has published a fix in the SolarWinds Platform release referenced by the SolarWinds Security Advisory CVE-2024-45710. Apply the vendor-recommended version to the SolarWinds node and verify the patched build after installation.
Workarounds
- Remove low-privileged local accounts from SolarWinds nodes until patching is complete
- Enforce AppLocker or Windows Defender Application Control (WDAC) policies that block execution of unsigned binaries from user-writable directories
- Review and remove any writable, non-system entries from the system PATH on affected hosts
# Example: audit NTFS permissions on SolarWinds install directory for non-admin write access
icacls "C:\Program Files (x86)\SolarWinds\Orion" /T /C | findstr /I "Users Everyone Authenticated"
# Example: enable file-system auditing on the install directory
auditpol /set /subcategory:"File System" /success:enable /failure:enable
Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.
Sources: National Vulnerability Database, CISA KEV, Exploit-DB